Extech EX623A True RMS AC/DC Clamp Meter with IR thermometer, NCV, 0.01 to 600 A, comprend certificat d'étalonnage de traçabilité

Modèle: EX623A-NIST

Extech EX623A True RMS AC/DC Clamp Meter with IR thermometer, NCV, 0.01 to 600 A, comprend certificat d'étalonnage de traçabilité

Modèle: EX623A-NIST

Excellent solution for testing requirements, this True RMS AC/DC clamp meter features dual thermocouple inputs for T1, T2, and T1-T2 differential temperature measurement, being an ideal all-in-one solution for accurate readings. In addition, it includes a built-in infrared thermometer and laser pointer for pinpointing hot spots. Ce produit comprend un certificat d'étalonnage de traçabilité avec toutes les données et incertitudes.

Excellent solution for testing requirements, this True RMS AC/DC clamp meter features dual thermocouple inputs for T1, T2, and T1-T2 differential temperature measurement, being an ideal all-in-one solution for accurate readings. In addition, it includes a built-in infrared thermometer and laser pointer for pinpointing hot spots. Ce produit comprend un certificat d'étalonnage de traçabilité avec toutes les données et incertitudes.

Votre prix $529.00 CAD
Disponibilité 1 en inventaire
Quantité

Extech EX623A-NIST offre

The EX623A features a Non-Contact Voltage (NCV) detector, which adds a layer of safety. Its DC micro-amp function is ideal for flame rod measurements in HVAC/R systems, and its capacitance measurement capability extends up to 40 mF.

Comes complete with test leads, a 9 V battery, two type K bead wire temperature probes, and a carrying case.

Ce produit comprend un certificat d'étalonnage de traçabilité avec toutes les données et incertitudes.

Caractéristiques

  • True RMS for accurate measurements of AC voltage and current measures
  • All-in-one HVAC/R meter
  • Combines the functionality of a 600 A AC/DC clamp meter with a built-in infrared thermometer
  • Dual type K thermometer with differential temperature function (T1, T2, T1-T2)
  • Non-Contact Voltage (NCV) detection enhances safety while measuring electrical installations
  • Perform safe and accurate inspections
  • AC/DC μA multimeter function specifically designed for HVAC/R flame rod current measurements and capacitance measurement up to 40 mF
  • Multimeter functions for DC voltage, resistance, capacitance, and frequency
  • LoZ mode prevents false readings due to ghost voltages
  • Low Pass Filter (LPF) ensures accurate measurements in electrically noisy environments
  • 1.25" (32 mm) jaw opening for conductors up to 500 MCM
  • 6000 count backlit LCD display
  • Rugged double molded housing
  • Auto power off with audible alert and disable function
  • Autoranging with manual override

Applications

  • HVAC/R systems
  • Energy
  • Electrical inspections
  • Electrical troubleshooting and maintenance
  • Building facilities
  • Commercial
  • Residential
  • Hospital
  • Universities

Spécifications pour le Extech EX623A-NIST

Type AC/DC
True Rms Yes
Display Counts 6000
Current AC: 0.01 to 600 A
DC: 0.01 to 600 A
Basic ACA accuracy: ±(1.5% + 5d)
Voltage AC: 0.1 mv to 600 V
DC: 0.1 mv to 600 V
µa Current 0.1 to 600 μA
Resistance 0.1 Ω to 60 MΩ
Capacitance 0.001 nF to 40 mF
Frequency 0.001 Hz to 100 kHz
Clamp: 0.1 to 400 Hz
Duty Cycle 0.5 to 99.0%
Temperature Type K: -58 to 1832°F (-50 to 1000°C)
Infrared: -58 to 518°F (-50 to 270°C)
Operating: 32 to 122°F (0 to 50°C)
Distance to Spot Ratio 8:1
NCV Detector Yes
Peak Hold Yes
Inrush (100 ms) Yes
LoZ Yes
Low Pass Filter Yes
Safety Category CAT III-600 V
Dimensions 9.4 x 3.7 x 1.74" (241 x 96 x 45 mm)
Jaw size: 1.25" (32 mm)
Weight 11.11 oz (315 g)

Le Extech EX623A-NIST comprend

  • Clamp Meter
  • NIST-Traceable Calibration Certificate
  • Double-molded Test Leads
  • Dual Type K Bead Wire Temperature Probe
  • Pouch
  • Carrying Case
  • 9 V Battery
  • User Manual
  • Two-Year Warranty

Poser une question sur le Extech EX623A True RMS AC/DC Clamp Meter with IR thermometer, NCV, 0.01 to 600 A,

Extech EX623A-NIST offre

The EX623A features a Non-Contact Voltage (NCV) detector, which adds a layer of safety. Its DC micro-amp function is ideal for flame rod measurements in HVAC/R systems, and its capacitance measurement capability extends up to 40 mF.

Comes complete with test leads, a 9 V battery, two type K bead wire temperature probes, and a carrying case.

Ce produit comprend un certificat d'étalonnage de traçabilité avec toutes les données et incertitudes.

Caractéristiques

  • True RMS for accurate measurements of AC voltage and current measures
  • All-in-one HVAC/R meter
  • Combines the functionality of a 600 A AC/DC clamp meter with a built-in infrared thermometer
  • Dual type K thermometer with differential temperature function (T1, T2, T1-T2)
  • Non-Contact Voltage (NCV) detection enhances safety while measuring electrical installations
  • Perform safe and accurate inspections
  • AC/DC μA multimeter function specifically designed for HVAC/R flame rod current measurements and capacitance measurement up to 40 mF
  • Multimeter functions for DC voltage, resistance, capacitance, and frequency
  • LoZ mode prevents false readings due to ghost voltages
  • Low Pass Filter (LPF) ensures accurate measurements in electrically noisy environments
  • 1.25" (32 mm) jaw opening for conductors up to 500 MCM
  • 6000 count backlit LCD display
  • Rugged double molded housing
  • Auto power off with audible alert and disable function
  • Autoranging with manual override

Applications

  • HVAC/R systems
  • Energy
  • Electrical inspections
  • Electrical troubleshooting and maintenance
  • Building facilities
  • Commercial
  • Residential
  • Hospital
  • Universities

Spécifications pour le Extech EX623A-NIST

Type AC/DC
True Rms Yes
Display Counts 6000
Current AC: 0.01 to 600 A
DC: 0.01 to 600 A
Basic ACA accuracy: ±(1.5% + 5d)
Voltage AC: 0.1 mv to 600 V
DC: 0.1 mv to 600 V
µa Current 0.1 to 600 μA
Resistance 0.1 Ω to 60 MΩ
Capacitance 0.001 nF to 40 mF
Frequency 0.001 Hz to 100 kHz
Clamp: 0.1 to 400 Hz
Duty Cycle 0.5 to 99.0%
Temperature Type K: -58 to 1832°F (-50 to 1000°C)
Infrared: -58 to 518°F (-50 to 270°C)
Operating: 32 to 122°F (0 to 50°C)
Distance to Spot Ratio 8:1
NCV Detector Yes
Peak Hold Yes
Inrush (100 ms) Yes
LoZ Yes
Low Pass Filter Yes
Safety Category CAT III-600 V
Dimensions 9.4 x 3.7 x 1.74" (241 x 96 x 45 mm)
Jaw size: 1.25" (32 mm)
Weight 11.11 oz (315 g)

Le Extech EX623A-NIST comprend

  • Clamp Meter
  • NIST-Traceable Calibration Certificate
  • Double-molded Test Leads
  • Dual Type K Bead Wire Temperature Probe
  • Pouch
  • Carrying Case
  • 9 V Battery
  • User Manual
  • Two-Year Warranty

Poser une question sur le Extech EX623A True RMS AC/DC Clamp Meter with IR thermometer, NCV, 0.01 to 600 A,