Eurotherm WV408-2000.V1 DC Powered DC Voltage/Current Input Isolating Signal Conditioner, ±150 V DC, ±25 mA

Modèle: WV408-2000.V1

Eurotherm WV408-2000.V1 DC Powered DC Voltage/Current Input Isolating Signal Conditioner, ±150 V DC, ±25 mA

Modèle: WV408-2000.V1

Eliminate wasted power with this DC-powered DC voltage/current input isolating signal conditioner featuring SmartPower to control its output supply. In addition, this alarm features four voltage input ranges and two current input ranges.

Eliminate wasted power with this DC-powered DC voltage/current input isolating signal conditioner featuring SmartPower to control its output supply. In addition, this alarm features four voltage input ranges and two current input ranges.

Discontinué!

Ce produit a été discontinué et n’est plus disponible. Il n'y a aucune option de remplacement.

Nous pouvons vous aider à trouver ce dont vous avez besoin:


Eurotherm WV408-2000.V1 offre

Accurate and stable, this DC-powered DC voltage/current input isolating signal conditioner is a high-accuracy signal conditioner with an isolated DC voltage or current output. In addition, this conditioner features removable terminals for easy service.

Caractéristiques

  • Lower power requirements with SmartPower
  • Improved accuracy
  • Bussed power with plug-in power clips
  • Removable terminals for easy service
  • Approved for use in Class I Div 2 Group A, B, C, D areas
  • RoHS compliant
  • Touch cal for best stability and accuracy
  • DIP switch configuration

Smart power

This signal conditioner uses Smart Power to control its output supply. Smart Power automatically adjusts the the voltage to drive the output loop to the required current. A low impedance current loop will subsequently require less voltage than a loop with higher impedance. Previous designs provided only a single supply at the highest voltage required to drive the highest impedance load. Using Smart Power results in power savings and reduces the operating temperature of the signal conditioner.

Approved for use in Class I Div 2 Group A, B, C, D areas

Users can now enjoy significant labor savings over traditional protection methods since there is no need for explosion proof enclosures and conduits. A Class I hazardous location is one in which flammable gases or vapors may be present in the air to be ignitable or explosive (typical applications include petroleum refineries, spray finishing areas, utility gas plants and fuel servicing areas). A Division 2 area is one in which the flammable gases or vapors are normally not present in an explosive concentration, but could accidentally exist. Group A is acetylene; Group B includes hydrogen; Group C includes ether; and Group D includes hydrocarbons, fuels and solvents.

Enhanced LED diagnostics

Other than when executing the pushbutton calibration routine, the LEDs blink under the following conditions:

  • Green: Flashes at 2 Hz when the input is under range; flashes at 8 Hz when the input is over range
  • Red: Flashes at 2 Hz when the output is under range; flashes at 8 Hz when the output is over range
  • An Under Range condition exists when the signal is lower than the operational low value minus 6.25% of the operational span. An Over Range condition exists when the signal is higher than the operational high value plus 6.25% of the operational span. A voltage output short circuit may cause an under range condition (RED blinking at 2Hz rate). A current output open circuit may cause an over range condition (RED blinking at an 8 Hz rate). There could be two or more LEDs blinking at the same time, which means the module has more than one error condition. Only when all error conditions have been removed, will the LEDs be back to normal (Green ON, Red and Yellow Off).

    Spécifications pour le Eurotherm WV408-2000.V1

    Zero and Span Adjustment ±95% of full scale
    Input Accuracy ±0.015% of full scale
    Outputs Voltage: 0 to 10 V DC
    Source impedance: <10 Ω
    Drive: 10 mA
    Current: 0 to 20 mA
    Source impedance: >100 kΩ
    Compliance: 20 V at 20 mA (1 kΩ maximum)
    Output Accuracy ±0.05% of full scale local range
    Selection By DIP switch
    Response Time 100 ms (10 to 90%)
    Stability ±100 ppm of full scale/°C (±0.01%/°C)
    Common Mode Rejection 120 dB at DC
    >90 dB at 60 Hz, or better
    Isolation 1800 V DC or peak AC between input, output and power
    ESD Susceptibility Capable of IEC 801-2 level 3 (8 kV)
    Host Module Interface IR Link
    Humidity (non-condensing) Operating: 15 to 95% RH at 113°F (45°C)
    Storage: 90% RH for 24 hours at 140°F (60°C)
    Temperature Operating: 32 to 140°F (0 to 60°C)
    Storage: -13 to 185°F (-25 to 85°C)
    Agency Approvals (EMC and Safety) UL recognized per standard UL508 (File No.E99775)
    CE conformance per EMC directive 2004/108/EC and low voltage directive 2006/95/EC (input <75 V DC, only)
    RoHS compliant
    Power 9 to 30 V DC; 1 W typical, 2 W maximum
    Dimensions 4.39 x 3.54 x 0.5" (111.6 x 90 x 12.7 mm)
    DIN rail case
    Inputs Voltage:
    ±150 mV, ±1.5 V, ±15 V or ±150 V DC
    Impedance: >100 kΩ
    Over voltage: 180 Vrms

    Current:
    ±2.5 mA or ±25 mA
    Impedance: <75 Ω
    Over current: 170 mA, protected by resetting fuse
    Over voltage: 60 V

    Le Eurotherm WV408-2000.V1 comprend

    • Eurotherm WV408-2000.V1 DC Powered DC Voltage/Current Input Isolating Signal Conditioner, ±150 V DC, ±25 mA

    Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Eurotherm WV408-2000.V1 DC Powered DC Voltage/Current Input Isolating Signal Conditioner, ±150 V DC, ±25 mA.

    Eurotherm H910-0024 Bloc d'alimentation pour montage sur rail DIN, 1000 mA à 24 V CC, 115 à 230 V CA H910-0024
    Idéal pour une utilisation avec des produits alimentés en 24 V CC, ce bloc d'alimentation pour montage sur rail DIN fournit jusqu'à 1000 mA à 24 V CC. De plus, ce bloc d'alimentation est doté d'un indicateur de puissance à DEL, d'une protection par fusible d'entrée et d'une protection contre les courts-circuits CC en sortie.




    Eurotherm H915-0001-1 Alimentation à montage sur rail DIN, 2300 mA à 24 V CC, 85 à 265 V CA H915-0001-1
    Idéale pour une utilisation avec des produits alimentés en 24 V CC, cette alimentation à montage sur rail DIN fournit jusqu'à 2300 mA à 24 V CC et dispose de plusieurs bornes de raccordement de fils. De plus, cette alimentation comprend un indicateur de puissance à DEL, une protection par fusible d'entrée et une protection contre les courts-circuits de sortie CC.




    Eurotherm MB03-0000 Support d'extrémité pour le MD03 MB03-0000
    Compatible avec le rail DIN MD03, ce support d'extrémité est un accessoire ou une pièce de rechange.




    Eurotherm MD03-0000 Rail DIN TS35 x 7.5, 2 m MD03-0000
    Compatible avec les conditionneurs de signaux, isolateurs, alarmes et alimentations de la série WV, ce rail DIN TS35 x 7.5 est un accessoire ou une pièce de rechange. De plus, ce rail présente une longueur de 2 m (6.56').




    Poser une question sur le Eurotherm WV408-2000.V1 DC Powered DC Voltage/Current Input Isolating Signal Conditioner, ±150 V DC, ±25 mA

    Eurotherm WV408-2000.V1 offre

    Accurate and stable, this DC-powered DC voltage/current input isolating signal conditioner is a high-accuracy signal conditioner with an isolated DC voltage or current output. In addition, this conditioner features removable terminals for easy service.

    Caractéristiques

    • Lower power requirements with SmartPower
    • Improved accuracy
    • Bussed power with plug-in power clips
    • Removable terminals for easy service
    • Approved for use in Class I Div 2 Group A, B, C, D areas
    • RoHS compliant
    • Touch cal for best stability and accuracy
    • DIP switch configuration

    Smart power

    This signal conditioner uses Smart Power to control its output supply. Smart Power automatically adjusts the the voltage to drive the output loop to the required current. A low impedance current loop will subsequently require less voltage than a loop with higher impedance. Previous designs provided only a single supply at the highest voltage required to drive the highest impedance load. Using Smart Power results in power savings and reduces the operating temperature of the signal conditioner.

    Approved for use in Class I Div 2 Group A, B, C, D areas

    Users can now enjoy significant labor savings over traditional protection methods since there is no need for explosion proof enclosures and conduits. A Class I hazardous location is one in which flammable gases or vapors may be present in the air to be ignitable or explosive (typical applications include petroleum refineries, spray finishing areas, utility gas plants and fuel servicing areas). A Division 2 area is one in which the flammable gases or vapors are normally not present in an explosive concentration, but could accidentally exist. Group A is acetylene; Group B includes hydrogen; Group C includes ether; and Group D includes hydrocarbons, fuels and solvents.

    Enhanced LED diagnostics

    Other than when executing the pushbutton calibration routine, the LEDs blink under the following conditions:

  • Green: Flashes at 2 Hz when the input is under range; flashes at 8 Hz when the input is over range
  • Red: Flashes at 2 Hz when the output is under range; flashes at 8 Hz when the output is over range
  • An Under Range condition exists when the signal is lower than the operational low value minus 6.25% of the operational span. An Over Range condition exists when the signal is higher than the operational high value plus 6.25% of the operational span. A voltage output short circuit may cause an under range condition (RED blinking at 2Hz rate). A current output open circuit may cause an over range condition (RED blinking at an 8 Hz rate). There could be two or more LEDs blinking at the same time, which means the module has more than one error condition. Only when all error conditions have been removed, will the LEDs be back to normal (Green ON, Red and Yellow Off).

    Spécifications pour le Eurotherm WV408-2000.V1

    Zero and Span Adjustment ±95% of full scale
    Input Accuracy ±0.015% of full scale
    Outputs Voltage: 0 to 10 V DC
    Source impedance: <10 Ω
    Drive: 10 mA
    Current: 0 to 20 mA
    Source impedance: >100 kΩ
    Compliance: 20 V at 20 mA (1 kΩ maximum)
    Output Accuracy ±0.05% of full scale local range
    Selection By DIP switch
    Response Time 100 ms (10 to 90%)
    Stability ±100 ppm of full scale/°C (±0.01%/°C)
    Common Mode Rejection 120 dB at DC
    >90 dB at 60 Hz, or better
    Isolation 1800 V DC or peak AC between input, output and power
    ESD Susceptibility Capable of IEC 801-2 level 3 (8 kV)
    Host Module Interface IR Link
    Humidity (non-condensing) Operating: 15 to 95% RH at 113°F (45°C)
    Storage: 90% RH for 24 hours at 140°F (60°C)
    Temperature Operating: 32 to 140°F (0 to 60°C)
    Storage: -13 to 185°F (-25 to 85°C)
    Agency Approvals (EMC and Safety) UL recognized per standard UL508 (File No.E99775)
    CE conformance per EMC directive 2004/108/EC and low voltage directive 2006/95/EC (input <75 V DC, only)
    RoHS compliant
    Power 9 to 30 V DC; 1 W typical, 2 W maximum
    Dimensions 4.39 x 3.54 x 0.5" (111.6 x 90 x 12.7 mm)
    DIN rail case
    Inputs Voltage:
    ±150 mV, ±1.5 V, ±15 V or ±150 V DC
    Impedance: >100 kΩ
    Over voltage: 180 Vrms

    Current:
    ±2.5 mA or ±25 mA
    Impedance: <75 Ω
    Over current: 170 mA, protected by resetting fuse
    Over voltage: 60 V

    Le Eurotherm WV408-2000.V1 comprend

    • Eurotherm WV408-2000.V1 DC Powered DC Voltage/Current Input Isolating Signal Conditioner, ±150 V DC, ±25 mA

    Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Eurotherm WV408-2000.V1 DC Powered DC Voltage/Current Input Isolating Signal Conditioner, ±150 V DC, ±25 mA.

    Eurotherm H910-0024 Bloc d'alimentation pour montage sur rail DIN, 1000 mA à 24 V CC, 115 à 230 V CA H910-0024
    Idéal pour une utilisation avec des produits alimentés en 24 V CC, ce bloc d'alimentation pour montage sur rail DIN fournit jusqu'à 1000 mA à 24 V CC. De plus, ce bloc d'alimentation est doté d'un indicateur de puissance à DEL, d'une protection par fusible d'entrée et d'une protection contre les courts-circuits CC en sortie.




    Eurotherm H915-0001-1 Alimentation à montage sur rail DIN, 2300 mA à 24 V CC, 85 à 265 V CA H915-0001-1
    Idéale pour une utilisation avec des produits alimentés en 24 V CC, cette alimentation à montage sur rail DIN fournit jusqu'à 2300 mA à 24 V CC et dispose de plusieurs bornes de raccordement de fils. De plus, cette alimentation comprend un indicateur de puissance à DEL, une protection par fusible d'entrée et une protection contre les courts-circuits de sortie CC.




    Eurotherm MB03-0000 Support d'extrémité pour le MD03 MB03-0000
    Compatible avec le rail DIN MD03, ce support d'extrémité est un accessoire ou une pièce de rechange.




    Eurotherm MD03-0000 Rail DIN TS35 x 7.5, 2 m MD03-0000
    Compatible avec les conditionneurs de signaux, isolateurs, alarmes et alimentations de la série WV, ce rail DIN TS35 x 7.5 est un accessoire ou une pièce de rechange. De plus, ce rail présente une longueur de 2 m (6.56').




    Poser une question sur le Eurotherm WV408-2000.V1 DC Powered DC Voltage/Current Input Isolating Signal Conditioner, ±150 V DC, ±25 mA

    Plus de produits Eurotherm