Eurotherm WV168-2000.V1 DC Powered AC Input Limit Alarm, 50 to 250 V, 20 to 100 mA

Modèle: WV168-2000.V1

Eurotherm WV168-2000.V1 DC Powered AC Input Limit Alarm, 50 to 250 V, 20 to 100 mA

Modèle: WV168-2000.V1

Choose between eight input voltage ranges with this DC-powered AC input limit alarm which provides relay contact closures at a preset AC input level. In addition, this alarm features two contact closures, and the input type and alarm functions are field configurable.

Choose between eight input voltage ranges with this DC-powered AC input limit alarm which provides relay contact closures at a preset AC input level. In addition, this alarm features two contact closures, and the input type and alarm functions are field configurable.

Discontinué!

Ce produit a été discontinué et n’est plus disponible. Il n'y a aucune option de remplacement.

Nous pouvons vous aider à trouver ce dont vous avez besoin:


Eurotherm WV168-2000.V1 offre

Accurate and stable, this DC-powered AC input limit alarm features two standard non-latching SPDT relays. In addition, this alarm features high or low trips and failsafe or non-failsafe operation.

Caractéristiques

  • Programmable high or low, failsafe or non-failsafe
  • Improved accuracy
  • Adjustable deadband
  • Bussed power with plug-in power clips
  • Removable terminals for easy service
  • Touch cal for best stability and accuracy
  • RoHS compliant
  • LED trip and input indicators

Spécifications pour le Eurotherm WV168-2000.V1

Inputs Voltage input ranges: 50 mV, 150 mV, 500 mV, 5 V, 20 V, 50 V, 150 V, 250 V
Impedance: >100 kΩ
Overvoltage: 275 V AC
Frequency range: 40 to 400 Hz

Current input ranges:
20 mA, 100 mA
Impedance: 10 Ω, typical
Overcurrent: 200 mA, maximum
Overvoltage: 60 V
Minimum Deadband (Range/Deadband) 50 mV, 0.2% (100 uV)
150 mV, 0.2% (300 uV)
500 mV, 0.2% (1 mV)
5 V, 0.1% (5 mV)
20 V, 0.1% (20 mV)
50 V, 0.1% (50 mV)
150 V, 0.1% (150 mV)
250 V, 0.1% (250 mV)
20 mA, 0.1% (20 uA)
100 mA, 0.1% (100 uA)
Response Time Dynamic deadband: Relay status will change when proper setpoint/process condition exists for 100 ms or greater
Normal mode (analog filtering): <250 ms
Setpoint Effectivity: Setpoints are adjustable (by pushbutton) over 100% of the selected input span

Repeatability (constant temperature):
>200 mV, 10 mA: 0.1% of full scale
<200 mV, 10 mA: 0.2% of full scale
Relay Contacts 2 SPDT (2 form C) relays, 1 relay per setpoint

Current rating (general use):
120 V AC: 5 A; 240 V AC: 2 A; 28 V DC: 5 A
Material: Gold flash over silver alloy
Electrical life: 105 operations
Local Range Selection By DIP switch
Stability ±100 ppm of FS/°C
Common Mode Rejection 120 dB at DC, >90 dB at 60 Hz, or better
Isolation 1800 V DC
Host Module Interface IR link
Humidity (Non-Condensing) Operating: 15 to 95% RH at 113°F (45°C)
Storage: 90% RH for 24 hours at 140°F (60°C)
Temperature Operating: 32 to 140°F (0 to 60°C)
Storage: -13 to 185°F (-25 to 85°C)
Agency Approvals (EMC and Safety) UL recognized per standard UL508 (File No.E99775)
CE conformance per EMC directive 2004/108/EC and low voltage directive 2006/95/EC (Input <75 V DC, only)
RoHS compliant
Power 9 to 30 V DC; 1.2 W typical, (3.25 W maximum both relays energized)
Dimensions 4.39 x 3.54 x 0.69" (111.6 x 90 x 17.5 mm)
DIN rail case

Le Eurotherm WV168-2000.V1 comprend

  • Eurotherm WV168-2000.V1 DC Powered AC Input Limit Alarm, 50 to 250 V, 20 to 100 mA

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Eurotherm WV168-2000.V1 DC Powered AC Input Limit Alarm, 50 to 250 V, 20 to 100 mA.

Eurotherm H910-0024 Bloc d'alimentation pour montage sur rail DIN, 1000 mA à 24 V CC, 115 à 230 V CA H910-0024
Idéal pour une utilisation avec des produits alimentés en 24 V CC, ce bloc d'alimentation pour montage sur rail DIN fournit jusqu'à 1000 mA à 24 V CC. De plus, ce bloc d'alimentation est doté d'un indicateur de puissance à DEL, d'une protection par fusible d'entrée et d'une protection contre les courts-circuits CC en sortie.




Eurotherm H915-0001-1 Alimentation à montage sur rail DIN, 2300 mA à 24 V CC, 85 à 265 V CA H915-0001-1
Idéale pour une utilisation avec des produits alimentés en 24 V CC, cette alimentation à montage sur rail DIN fournit jusqu'à 2300 mA à 24 V CC et dispose de plusieurs bornes de raccordement de fils. De plus, cette alimentation comprend un indicateur de puissance à DEL, une protection par fusible d'entrée et une protection contre les courts-circuits de sortie CC.




Eurotherm MB03-0000 Support d'extrémité pour le MD03 MB03-0000
Compatible avec le rail DIN MD03, ce support d'extrémité est un accessoire ou une pièce de rechange.




Eurotherm MD03-0000 Rail DIN TS35 x 7.5, 2 m MD03-0000
Compatible avec les conditionneurs de signaux, isolateurs, alarmes et alimentations de la série WV, ce rail DIN TS35 x 7.5 est un accessoire ou une pièce de rechange. De plus, ce rail présente une longueur de 2 m (6.56').




Poser une question sur le Eurotherm WV168-2000.V1 DC Powered AC Input Limit Alarm, 50 to 250 V, 20 to 100 mA

Eurotherm WV168-2000.V1 offre

Accurate and stable, this DC-powered AC input limit alarm features two standard non-latching SPDT relays. In addition, this alarm features high or low trips and failsafe or non-failsafe operation.

Caractéristiques

  • Programmable high or low, failsafe or non-failsafe
  • Improved accuracy
  • Adjustable deadband
  • Bussed power with plug-in power clips
  • Removable terminals for easy service
  • Touch cal for best stability and accuracy
  • RoHS compliant
  • LED trip and input indicators

Spécifications pour le Eurotherm WV168-2000.V1

Inputs Voltage input ranges: 50 mV, 150 mV, 500 mV, 5 V, 20 V, 50 V, 150 V, 250 V
Impedance: >100 kΩ
Overvoltage: 275 V AC
Frequency range: 40 to 400 Hz

Current input ranges:
20 mA, 100 mA
Impedance: 10 Ω, typical
Overcurrent: 200 mA, maximum
Overvoltage: 60 V
Minimum Deadband (Range/Deadband) 50 mV, 0.2% (100 uV)
150 mV, 0.2% (300 uV)
500 mV, 0.2% (1 mV)
5 V, 0.1% (5 mV)
20 V, 0.1% (20 mV)
50 V, 0.1% (50 mV)
150 V, 0.1% (150 mV)
250 V, 0.1% (250 mV)
20 mA, 0.1% (20 uA)
100 mA, 0.1% (100 uA)
Response Time Dynamic deadband: Relay status will change when proper setpoint/process condition exists for 100 ms or greater
Normal mode (analog filtering): <250 ms
Setpoint Effectivity: Setpoints are adjustable (by pushbutton) over 100% of the selected input span

Repeatability (constant temperature):
>200 mV, 10 mA: 0.1% of full scale
<200 mV, 10 mA: 0.2% of full scale
Relay Contacts 2 SPDT (2 form C) relays, 1 relay per setpoint

Current rating (general use):
120 V AC: 5 A; 240 V AC: 2 A; 28 V DC: 5 A
Material: Gold flash over silver alloy
Electrical life: 105 operations
Local Range Selection By DIP switch
Stability ±100 ppm of FS/°C
Common Mode Rejection 120 dB at DC, >90 dB at 60 Hz, or better
Isolation 1800 V DC
Host Module Interface IR link
Humidity (Non-Condensing) Operating: 15 to 95% RH at 113°F (45°C)
Storage: 90% RH for 24 hours at 140°F (60°C)
Temperature Operating: 32 to 140°F (0 to 60°C)
Storage: -13 to 185°F (-25 to 85°C)
Agency Approvals (EMC and Safety) UL recognized per standard UL508 (File No.E99775)
CE conformance per EMC directive 2004/108/EC and low voltage directive 2006/95/EC (Input <75 V DC, only)
RoHS compliant
Power 9 to 30 V DC; 1.2 W typical, (3.25 W maximum both relays energized)
Dimensions 4.39 x 3.54 x 0.69" (111.6 x 90 x 17.5 mm)
DIN rail case

Le Eurotherm WV168-2000.V1 comprend

  • Eurotherm WV168-2000.V1 DC Powered AC Input Limit Alarm, 50 to 250 V, 20 to 100 mA

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Eurotherm WV168-2000.V1 DC Powered AC Input Limit Alarm, 50 to 250 V, 20 to 100 mA.

Eurotherm H910-0024 Bloc d'alimentation pour montage sur rail DIN, 1000 mA à 24 V CC, 115 à 230 V CA H910-0024
Idéal pour une utilisation avec des produits alimentés en 24 V CC, ce bloc d'alimentation pour montage sur rail DIN fournit jusqu'à 1000 mA à 24 V CC. De plus, ce bloc d'alimentation est doté d'un indicateur de puissance à DEL, d'une protection par fusible d'entrée et d'une protection contre les courts-circuits CC en sortie.




Eurotherm H915-0001-1 Alimentation à montage sur rail DIN, 2300 mA à 24 V CC, 85 à 265 V CA H915-0001-1
Idéale pour une utilisation avec des produits alimentés en 24 V CC, cette alimentation à montage sur rail DIN fournit jusqu'à 2300 mA à 24 V CC et dispose de plusieurs bornes de raccordement de fils. De plus, cette alimentation comprend un indicateur de puissance à DEL, une protection par fusible d'entrée et une protection contre les courts-circuits de sortie CC.




Eurotherm MB03-0000 Support d'extrémité pour le MD03 MB03-0000
Compatible avec le rail DIN MD03, ce support d'extrémité est un accessoire ou une pièce de rechange.




Eurotherm MD03-0000 Rail DIN TS35 x 7.5, 2 m MD03-0000
Compatible avec les conditionneurs de signaux, isolateurs, alarmes et alimentations de la série WV, ce rail DIN TS35 x 7.5 est un accessoire ou une pièce de rechange. De plus, ce rail présente une longueur de 2 m (6.56').




Poser une question sur le Eurotherm WV168-2000.V1 DC Powered AC Input Limit Alarm, 50 to 250 V, 20 to 100 mA

Plus de produits Eurotherm