Eurotherm Q510 Action I/Q Loop Powered RTD Input Two-Wire Transmitter, four-channel, 0 to 300°F

Modèle: Q510-4B07

Eurotherm Q510 Action I/Q Loop Powered RTD Input Two-Wire Transmitter, four-channel, 0 to 300°F

Modèle: Q510-4B07

Reduce the cost of signal conditioning with this loop-powered RTD input two-wire transmitter that provides four current loop outputs in proportion to the PT100 Ω RTD inputs. In addition, this transmitter features a DIN rail mount package, four channels, and an input range of 0 to 300°F.

Reduce the cost of signal conditioning with this loop-powered RTD input two-wire transmitter that provides four current loop outputs in proportion to the PT100 Ω RTD inputs. In addition, this transmitter features a DIN rail mount package, four channels, and an input range of 0 to 300°F.

Discontinué!

Ce produit a été discontinué et n’est plus disponible. Il n'y a aucune option de remplacement.

Nous pouvons vous aider à trouver ce dont vous avez besoin:


Eurotherm Q510-4B07 offre

Ideal for remote locations, this loop-powered RTD input two-wire transmitter features SnapLoc plug-in screw terminals for easy installation and low mean-time-to-repair. In addition, two or more modules can slide together and interlock for stable, high-density mounting.

Caractéristiques

  • Four two-wire transmitters in a single package
  • Output linear to input temperature
  • Standard input ranges
  • High density DIN rail mounting
  • SnapLoc™ plug-in terminals
  • Output loop powered from 10 to 35 V DC

Applications

  • Remote locations
  • Measure temperatures in a vessel or cell

Spécifications pour le Eurotherm Q510-4B07

Input Accepts two, 3-wire Pt100 RTDs (alpha = 0.00385 Ω/Ω/°C)
Range: 0 to 300°F
Excitation: 0.8 mA, typical, each channel
Leadwire effect: <1% of full scale output, maximum at 40 Ω maximum/lead
Output Range: 4 to 20 mA
Accuracy: ≤0.1% of full-scale input typical, <0.4% maximum, including linearity, repeatability and hysteresis
Supply Voltage Range 10 to 35 V DC, each channel
Adjustability Front accessed 10 turn pot., ±2% of span for zero and span, typical
Stability ≤0.025%/°C of full-scale maximum for full-scale and zero
ESD Susceptibility Meets IEC 801-2 level 2 (4 kV)
Response Time 50 msec typical (10 to 90%)
Temperature Operating: -40 to 176°F (-40 to 80°C)
Storage: -40 to 176°F (-40 to 80°C)
Humidity (Non-Condensing) Operating: 15 to 90% at 113°F (at 45°C)
Wire Terminals Socketed screw terminals for 12 to 22 AWG
Agency Approvals CSA certified per standard C22.2 (File No. LR42272)
UL recognized per standard UL508 (File No. E99775)
Dimensions 4.59 x 4.12 x 0.88" (116.47 x 104.6 x 22.29 mm)
Weight 0.34 lbs (154.22 g)

Le Eurotherm Q510-4B07 comprend

  • Eurotherm Q510 Action I/Q Loop Powered RTD Input Two-Wire Transmitter, four-channel, 0 to 300°F

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Eurotherm Q510 Action I/Q Loop Powered RTD Input Two-Wire Transmitter, four-channel, 0 to 300°F.

Eurotherm H910-0024 Bloc d'alimentation pour montage sur rail DIN, 1000 mA à 24 V CC, 115 à 230 V CA H910-0024
Idéal pour une utilisation avec des produits alimentés en 24 V CC, ce bloc d'alimentation pour montage sur rail DIN fournit jusqu'à 1000 mA à 24 V CC. De plus, ce bloc d'alimentation est doté d'un indicateur de puissance à DEL, d'une protection par fusible d'entrée et d'une protection contre les courts-circuits CC en sortie.




Eurotherm H915-0001-1 Alimentation à montage sur rail DIN, 2300 mA à 24 V CC, 85 à 265 V CA H915-0001-1
Idéale pour une utilisation avec des produits alimentés en 24 V CC, cette alimentation à montage sur rail DIN fournit jusqu'à 2300 mA à 24 V CC et dispose de plusieurs bornes de raccordement de fils. De plus, cette alimentation comprend un indicateur de puissance à DEL, une protection par fusible d'entrée et une protection contre les courts-circuits de sortie CC.




Eurotherm MD03-0000 Rail DIN TS35 x 7.5, 2 m MD03-0000
Compatible avec les conditionneurs de signaux, isolateurs, alarmes et alimentations de la série WV, ce rail DIN TS35 x 7.5 est un accessoire ou une pièce de rechange. De plus, ce rail présente une longueur de 2 m (6.56').




Poser une question sur le Eurotherm Q510 Action I/Q Loop Powered RTD Input Two-Wire Transmitter, four-channel, 0 to 300°F

Eurotherm Q510-4B07 offre

Ideal for remote locations, this loop-powered RTD input two-wire transmitter features SnapLoc plug-in screw terminals for easy installation and low mean-time-to-repair. In addition, two or more modules can slide together and interlock for stable, high-density mounting.

Caractéristiques

  • Four two-wire transmitters in a single package
  • Output linear to input temperature
  • Standard input ranges
  • High density DIN rail mounting
  • SnapLoc™ plug-in terminals
  • Output loop powered from 10 to 35 V DC

Applications

  • Remote locations
  • Measure temperatures in a vessel or cell

Spécifications pour le Eurotherm Q510-4B07

Input Accepts two, 3-wire Pt100 RTDs (alpha = 0.00385 Ω/Ω/°C)
Range: 0 to 300°F
Excitation: 0.8 mA, typical, each channel
Leadwire effect: <1% of full scale output, maximum at 40 Ω maximum/lead
Output Range: 4 to 20 mA
Accuracy: ≤0.1% of full-scale input typical, <0.4% maximum, including linearity, repeatability and hysteresis
Supply Voltage Range 10 to 35 V DC, each channel
Adjustability Front accessed 10 turn pot., ±2% of span for zero and span, typical
Stability ≤0.025%/°C of full-scale maximum for full-scale and zero
ESD Susceptibility Meets IEC 801-2 level 2 (4 kV)
Response Time 50 msec typical (10 to 90%)
Temperature Operating: -40 to 176°F (-40 to 80°C)
Storage: -40 to 176°F (-40 to 80°C)
Humidity (Non-Condensing) Operating: 15 to 90% at 113°F (at 45°C)
Wire Terminals Socketed screw terminals for 12 to 22 AWG
Agency Approvals CSA certified per standard C22.2 (File No. LR42272)
UL recognized per standard UL508 (File No. E99775)
Dimensions 4.59 x 4.12 x 0.88" (116.47 x 104.6 x 22.29 mm)
Weight 0.34 lbs (154.22 g)

Le Eurotherm Q510-4B07 comprend

  • Eurotherm Q510 Action I/Q Loop Powered RTD Input Two-Wire Transmitter, four-channel, 0 to 300°F

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Eurotherm Q510 Action I/Q Loop Powered RTD Input Two-Wire Transmitter, four-channel, 0 to 300°F.

Eurotherm H910-0024 Bloc d'alimentation pour montage sur rail DIN, 1000 mA à 24 V CC, 115 à 230 V CA H910-0024
Idéal pour une utilisation avec des produits alimentés en 24 V CC, ce bloc d'alimentation pour montage sur rail DIN fournit jusqu'à 1000 mA à 24 V CC. De plus, ce bloc d'alimentation est doté d'un indicateur de puissance à DEL, d'une protection par fusible d'entrée et d'une protection contre les courts-circuits CC en sortie.




Eurotherm H915-0001-1 Alimentation à montage sur rail DIN, 2300 mA à 24 V CC, 85 à 265 V CA H915-0001-1
Idéale pour une utilisation avec des produits alimentés en 24 V CC, cette alimentation à montage sur rail DIN fournit jusqu'à 2300 mA à 24 V CC et dispose de plusieurs bornes de raccordement de fils. De plus, cette alimentation comprend un indicateur de puissance à DEL, une protection par fusible d'entrée et une protection contre les courts-circuits de sortie CC.




Eurotherm MD03-0000 Rail DIN TS35 x 7.5, 2 m MD03-0000
Compatible avec les conditionneurs de signaux, isolateurs, alarmes et alimentations de la série WV, ce rail DIN TS35 x 7.5 est un accessoire ou une pièce de rechange. De plus, ce rail présente une longueur de 2 m (6.56').




Poser une question sur le Eurotherm Q510 Action I/Q Loop Powered RTD Input Two-Wire Transmitter, four-channel, 0 to 300°F

Plus de produits Eurotherm