Eagle Eye VS-24 Hydrogen Gas Ventilation System

Modèle: VS-24

Eagle Eye VS-24 Hydrogen Gas Ventilation System

Modèle: VS-24

Compatible with HGD-2000 and HGD-3000 hydrogen gas detectors, this hydrogen gas ventilation system is for battery charging rooms and other areas where hydrogen may be present and includes a “Positive Airflow Shut Off” feature. Airflow can be stopped from passing through the fans by an external electric command.

Compatible with HGD-2000 and HGD-3000 hydrogen gas detectors, this hydrogen gas ventilation system is for battery charging rooms and other areas where hydrogen may be present and includes a “Positive Airflow Shut Off” feature. Airflow can be stopped from passing through the fans by an external electric command.

Ce produit est pour commandes spéciales et ne peut pas être retourné ou annulé.

Votre prix $22512.00 CAD
Disponibilité 2 à 3 semaines
Quantité

Eagle Eye VS-24 Offers

The hydrogen gas ventilation system has a high sensitivity and stability.

Features

  • Automatic operation and continuous 24/7 monitoring
  • Long life-span for reliable monitoring
  • Inexpensive protection for equipment and personnel
  • Compliance with IEEE Std 450
  • Compliance with National Fire Protection Agency (NFPA) article 64
  • Compliance with uniform building code (UBC) section 6400

Applications

  • Utilities and power plants
  • UPS power systems
  • Fuel cell test stations
  • Nuclear waste reforming
  • Hydrogen refueling stations
  • Fire department
  • Battery suppliers
  • Battery charging rooms
  • Motive power
  • Golf cart

Eagle Eye VS-24 Specifications

Connections Input: positive shutoff control, N.O. dry contacts
Output: 1% fan running, 2% alarm, N.O. dry contacts
Mounting 4 x 1.5" (38 mm) standard 24" (607 mm)
Positive Shut-Off Dry contact activated, manually reset
Temperature Range -40 to 120°F (-40 to 48°C)
Humidity Little or no effect
Safety Standard 4 x fans rated at 850 CFM Total 3400 CFM
N+1 3 x fans at 850 CFM total 2550 CFM for 2550 ft2 (777 m2)
Dimensions: 24 x 24 x 18" (610 x 610 x 450 mm)
Weight: Fan: 51 lbs (23 kg)
Rain shield and damper: 24 lbs (10.9 kg)
Cliquer ici pour toutes les spécifications du Eagle Eye VS-24

Le Eagle Eye VS-24 comprend

  • Eagle Eye VS-24 Hydrogen Gas Ventilation System

Poser une question sur le Eagle Eye VS-24 Hydrogen Gas Ventilation System

Eagle Eye VS-24 Offers

The hydrogen gas ventilation system has a high sensitivity and stability.

Features

  • Automatic operation and continuous 24/7 monitoring
  • Long life-span for reliable monitoring
  • Inexpensive protection for equipment and personnel
  • Compliance with IEEE Std 450
  • Compliance with National Fire Protection Agency (NFPA) article 64
  • Compliance with uniform building code (UBC) section 6400

Applications

  • Utilities and power plants
  • UPS power systems
  • Fuel cell test stations
  • Nuclear waste reforming
  • Hydrogen refueling stations
  • Fire department
  • Battery suppliers
  • Battery charging rooms
  • Motive power
  • Golf cart

Eagle Eye VS-24 Specifications

Connections Input: positive shutoff control, N.O. dry contacts
Output: 1% fan running, 2% alarm, N.O. dry contacts
Mounting 4 x 1.5" (38 mm) standard 24" (607 mm)
Positive Shut-Off Dry contact activated, manually reset
Temperature Range -40 to 120°F (-40 to 48°C)
Humidity Little or no effect
Safety Standard 4 x fans rated at 850 CFM Total 3400 CFM
N+1 3 x fans at 850 CFM total 2550 CFM for 2550 ft2 (777 m2)
Dimensions: 24 x 24 x 18" (610 x 610 x 450 mm)
Weight: Fan: 51 lbs (23 kg)
Rain shield and damper: 24 lbs (10.9 kg)
Cliquer ici pour toutes les spécifications du Eagle Eye VS-24

Le Eagle Eye VS-24 comprend

  • Eagle Eye VS-24 Hydrogen Gas Ventilation System

Poser une question sur le Eagle Eye VS-24 Hydrogen Gas Ventilation System

Plus de produits Eagle Eye