The Incuba-102 air quality monitor is perfect for incubator monitoring and real-time datalogging of air quality analysis. This model has a CO2 sensor range of 0-10%. All Incuba models can be upgraded to add O2 (0-25%) as a reading.
The Incuba-102 air quality monitor is perfect for incubator monitoring and real-time datalogging of air quality analysis. This model has a CO2 sensor range of 0-10%. All Incuba models can be upgraded to add O2 (0-25%) as a reading.
Discontinué!
Ce produit a été discontinué et n’est plus disponible.
Il n’y a pas de remplacement direct, mais nous vous recommandons:
Vous ne trouvez pas ce que vous cherchez? Nous ferons une recherche et vous aiderons à trouver ce dont vous avez besoin.
Caractéristiques
Applications
| CO2 | |
| Sensor | NDIR |
| Range | 0 to 10% |
| Resolution | 0.1% |
| Accuracy | ±3% of rdg. |
| Relative Humidity | |
| Sensor | TFC |
| Range | 5 to 95% RH |
| Resolution | 0.1% RH |
| Accuracy | ±2% RH |
| Ambient Temperature | |
| Sensor | Pt100 |
| Range | -40 to 257°F (-40 to 125°C) |
| Resolution | 0.1°C/F |
| Accuracy | ±0.4°C (0 to 60°C) |
| Barometric Pressure | |
| Sensor | Solid State |
| Range | 260 to 1260 mbar |
| Resolution | 1 mbar |
| Accuracy | ±2 mbar |
| Temperature Type K T1 | |
| Sensor | Tc K |
| Range | 0 to 2000°F (0 to 1100°C) |
| Resolution | 0.1% |
| Accuracy | ±3% of rdg. |
| Optional O2 (Requires Upgrade) | |
| Sensor | Electrochemical |
| Range | 0 to 25% |
| Resolution | 0.1% |
| Accuracy | ±0.1% |
| Electromagnetic Compatibility | EN 61326-1, Portable Equipment |
Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le E Instruments Incuba-102 CO2 Incubator Air Quality Monitor, 0-10%.
| CO2 | |
| Sensor | NDIR |
| Range | 0 to 10% |
| Resolution | 0.1% |
| Accuracy | ±3% of rdg. |
| Relative Humidity | |
| Sensor | TFC |
| Range | 5 to 95% RH |
| Resolution | 0.1% RH |
| Accuracy | ±2% RH |
| Ambient Temperature | |
| Sensor | Pt100 |
| Range | -40 to 257°F (-40 to 125°C) |
| Resolution | 0.1°C/F |
| Accuracy | ±0.4°C (0 to 60°C) |
| Barometric Pressure | |
| Sensor | Solid State |
| Range | 260 to 1260 mbar |
| Resolution | 1 mbar |
| Accuracy | ±2 mbar |
| Temperature Type K T1 | |
| Sensor | Tc K |
| Range | 0 to 2000°F (0 to 1100°C) |
| Resolution | 0.1% |
| Accuracy | ±3% of rdg. |
| Optional O2 (Requires Upgrade) | |
| Sensor | Electrochemical |
| Range | 0 to 25% |
| Resolution | 0.1% |
| Accuracy | ±0.1% |
| Electromagnetic Compatibility | EN 61326-1, Portable Equipment |
Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le E Instruments Incuba-102 CO2 Incubator Air Quality Monitor, 0-10%.