E Instruments 4500-S Industrial and Commercial Combustion Analyzer, for O2, CO, CO2, NO, NOx and SO2

Modèle: 4500-S | No. de commande: BTU4500-S

E Instruments 4500-S Industrial and Commercial Combustion Analyzer, for O2, CO, CO2, NO, NOx and SO2

Modèle: 4500-S | No. de commande: BTU4500-S

The industrial and commercial combustion analyzer for O2, CO, CO2, NO, NOx and SO2 is a valuable hand-held tool designed for emissions monitoring and maintenance and tuning of combustion processes including boilers, burners, gas and diesel engines, turbines, furnaces, kilns, heaters, and laboratory analysis.

The industrial and commercial combustion analyzer for O2, CO, CO2, NO, NOx and SO2 is a valuable hand-held tool designed for emissions monitoring and maintenance and tuning of combustion processes including boilers, burners, gas and diesel engines, turbines, furnaces, kilns, heaters, and laboratory analysis.

Discontinué!

Ce produit a été discontinué et n’est plus disponible.
Voici le produit de remplacement direct :


E Instruments 4500-S Offers

Features

  • Unbreakable metal hose connectors
  • Dilution pump for CO auto-range measurements up to 100,000 ppm (10%)
  • Built-in impact printer (non-thermal)
  • Low NOx capable with 0.1 ppm resolution
  • All gas sensors are pre-calibrated and field replaceable
  • Efficiency, excess air, and CO2 calculations
  • Stack gas and air temperature measurements
  • Draft and differential pressure measurements
  • External water trap for condensate removal
  • Rechargeable lithium ion battery pack
  • Internal memory (up to 900 tests)
  • PC software package

E Instruments 4500-S Specifications

02 Sensor: Electrochemical
Range: 0 to 25%
Resolution: 0.1%
Accuracy: ±0.2% vol
CO (H2 compensated with built-in NOx filter) Sensor: Electrochemical
Range: 0 to 8000 ppm
Resolution: 1 ppm
Accuracy: ±8 ppm <400 ppm
±5% rdg up to 2000 ppm >br> ±10% rdg for >2000 ppm
CO Diluted Sensor: Electrochemical
Range: 0.8 to 10.00%
Resolution: 0.1%
Accuracy: ±10% rdg
CO2 Sensor: Calculated
Range: 0 to 99.9%
Resolution: 0.1%
NO Sensor:Electrochemical
Range: 0 to 5000 ppm
Resolution: 1 ppm
Accuracy: ±5 ppm <100 ppm
±5% rdg for >100 ppm
NO2 Sensor: Electrochemical
Range: 0 to 1000 ppm
Resolution: 1 ppm
Accuracy: ±5 ppm <100 ppm
±5% rdg for >100 ppm
Low NO Sensor: Electrochemical
Range: 0 to 100.0 ppm
Resolution: 0.1 ppm
±1.5 ppm <40 ppm
±5% rdg for <100 ppm
NOx Sensor: Calculated
Range: 0 to 5000 ppm
Resolution: 1 ppm
SO2 Sensor: Electrochemical
Range: 0 to 5000 ppm
Resolution: 1 ppm
Accuracy: ±5 ppm <100 ppm
±5% rdg for >100 ppm
CxHy (HC) Sensor:Pellistor
Range: 0 to 5%
Resolution: 0.01%
Accuracy: ±5% full scale
Tair Sensor:Pt100
Range: -4 to 248°F (-20 to 120°C)
Resolution: 0.1°F (0.1°C)
Accuracy: ±1°F (±1°C)
Tgas Sensor: TcK
Range: -4 to 2280°F (-20 to 1250°C)
Resolution: 0.1°F (0.1°C)
Accuracy: ±2°F (±2°C)l
Differential Temperature Sensor: Calculated
Range: -4 to 2280°F (-20 to 1250°C)
Resolution: 0.1°F (0.1°C)
Pressure/Draft Sensor: Semiconductor
Range: -4 to 80 in H2O
-10 to 200 mbar
Resolution: 0.001 in H2O
0.01 mbar
Accuracy: ±1% rdg.
Excess Air Sensor: Calculated
Range: 0 to 850%
Resolution: 1%
Efficiency Sensor: Calculated
Range: 0 to 100%
Resolution: 0.1%
Cliquer ici pour toutes les spécifications du E Instruments 4500-S

Le E Instruments 4500-S comprend

  • E Instruments 4500-S Industrial and Commercial Combustion Analyzer, for O2, CO, CO2, NO, NOx and SO2

Poser une question sur le E Instruments 4500-S Industrial and Commercial Combustion Analyzer, for O2, CO, CO2, NO, NOx and SO2

E Instruments 4500-S Offers

Features

  • Unbreakable metal hose connectors
  • Dilution pump for CO auto-range measurements up to 100,000 ppm (10%)
  • Built-in impact printer (non-thermal)
  • Low NOx capable with 0.1 ppm resolution
  • All gas sensors are pre-calibrated and field replaceable
  • Efficiency, excess air, and CO2 calculations
  • Stack gas and air temperature measurements
  • Draft and differential pressure measurements
  • External water trap for condensate removal
  • Rechargeable lithium ion battery pack
  • Internal memory (up to 900 tests)
  • PC software package

E Instruments 4500-S Specifications

02 Sensor: Electrochemical
Range: 0 to 25%
Resolution: 0.1%
Accuracy: ±0.2% vol
CO (H2 compensated with built-in NOx filter) Sensor: Electrochemical
Range: 0 to 8000 ppm
Resolution: 1 ppm
Accuracy: ±8 ppm <400 ppm
±5% rdg up to 2000 ppm >br> ±10% rdg for >2000 ppm
CO Diluted Sensor: Electrochemical
Range: 0.8 to 10.00%
Resolution: 0.1%
Accuracy: ±10% rdg
CO2 Sensor: Calculated
Range: 0 to 99.9%
Resolution: 0.1%
NO Sensor:Electrochemical
Range: 0 to 5000 ppm
Resolution: 1 ppm
Accuracy: ±5 ppm <100 ppm
±5% rdg for >100 ppm
NO2 Sensor: Electrochemical
Range: 0 to 1000 ppm
Resolution: 1 ppm
Accuracy: ±5 ppm <100 ppm
±5% rdg for >100 ppm
Low NO Sensor: Electrochemical
Range: 0 to 100.0 ppm
Resolution: 0.1 ppm
±1.5 ppm <40 ppm
±5% rdg for <100 ppm
NOx Sensor: Calculated
Range: 0 to 5000 ppm
Resolution: 1 ppm
SO2 Sensor: Electrochemical
Range: 0 to 5000 ppm
Resolution: 1 ppm
Accuracy: ±5 ppm <100 ppm
±5% rdg for >100 ppm
CxHy (HC) Sensor:Pellistor
Range: 0 to 5%
Resolution: 0.01%
Accuracy: ±5% full scale
Tair Sensor:Pt100
Range: -4 to 248°F (-20 to 120°C)
Resolution: 0.1°F (0.1°C)
Accuracy: ±1°F (±1°C)
Tgas Sensor: TcK
Range: -4 to 2280°F (-20 to 1250°C)
Resolution: 0.1°F (0.1°C)
Accuracy: ±2°F (±2°C)l
Differential Temperature Sensor: Calculated
Range: -4 to 2280°F (-20 to 1250°C)
Resolution: 0.1°F (0.1°C)
Pressure/Draft Sensor: Semiconductor
Range: -4 to 80 in H2O
-10 to 200 mbar
Resolution: 0.001 in H2O
0.01 mbar
Accuracy: ±1% rdg.
Excess Air Sensor: Calculated
Range: 0 to 850%
Resolution: 1%
Efficiency Sensor: Calculated
Range: 0 to 100%
Resolution: 0.1%
Cliquer ici pour toutes les spécifications du E Instruments 4500-S

Le E Instruments 4500-S comprend

  • E Instruments 4500-S Industrial and Commercial Combustion Analyzer, for O2, CO, CO2, NO, NOx and SO2

Poser une question sur le E Instruments 4500-S Industrial and Commercial Combustion Analyzer, for O2, CO, CO2, NO, NOx and SO2

Plus de produits E Instruments