Dwyer RHPLC-2N11 Series RHPLC North American Humidity/Temperature Transmitter, 2% accuracy, 4 to 20 mA

Modèle: RHPLC-2N11

Dwyer RHPLC-2N11 Series RHPLC North American Humidity/Temperature Transmitter, 2% accuracy, 4 to 20 mA

Modèle: RHPLC-2N11

The humidity/temperature transmitter boasts a 2% level of accuracy. It can be wall mounted for secure placement.

The humidity/temperature transmitter boasts a 2% level of accuracy. It can be wall mounted for secure placement.

Prix spécial $217.62 CAD
Prix régulier $234.00 CAD
Disponibilité 1 à 2 semaines
Quantité

Dwyer RHPLC-2N11 offre

Applications

  • Économiseurs d'air
  • Surveillance du confort ambiant

Spécifications pour le Dwyer RHPLC-2N11

Humidity Measurement Range 0 to 100% RH
Supported Measurement Unit(s) Celsius and Fahrenheit
Temperature Accuracy Current/volt temperature output: ±0.9° at 72°F (±0.3° at 25°C)
Response Time 8 seconds
Application(s) Relative Humidity
Humidity Accuracy ±2% 10 to 90% RH at 77°F (25°C); Drift: <0.25% RH/year
Storage Temperature -40 to 176°F (-40 to 80°C)
Power Source Electric
Power Requirements 10 to 35 V DC
Approvals CE
Product Weight 4.4 oz (125 g)
Product Type Compatibility Current, voltage, RTD or thermistor output sensors (sold separately)
Temperature Measurement Range -40 to 140°F (-40 to 60°C)
Connector Type(s) Screw terminal block

Le Dwyer RHPLC-2N11 comprend

  • Dwyer RHPLC-2N11 Series RHPLC North American Humidity/Temperature Transmitter, 2% accuracy, 4 to 20 mA

Poser une question sur le Dwyer RHPLC-2N11 Series RHPLC North American Humidity/Temperature Transmitter, 2% accuracy, 4 to 20 mA

Dwyer RHPLC-2N11 offre

Applications

  • Économiseurs d'air
  • Surveillance du confort ambiant

Spécifications pour le Dwyer RHPLC-2N11

Humidity Measurement Range 0 to 100% RH
Supported Measurement Unit(s) Celsius and Fahrenheit
Temperature Accuracy Current/volt temperature output: ±0.9° at 72°F (±0.3° at 25°C)
Response Time 8 seconds
Application(s) Relative Humidity
Humidity Accuracy ±2% 10 to 90% RH at 77°F (25°C); Drift: <0.25% RH/year
Storage Temperature -40 to 176°F (-40 to 80°C)
Power Source Electric
Power Requirements 10 to 35 V DC
Approvals CE
Product Weight 4.4 oz (125 g)
Product Type Compatibility Current, voltage, RTD or thermistor output sensors (sold separately)
Temperature Measurement Range -40 to 140°F (-40 to 60°C)
Connector Type(s) Screw terminal block