Dwyer IS626-12-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-200 psig)

Modèle: IS626-12-GH-P1-E1-S1

Dwyer IS626-12-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-200 psig)

Modèle: IS626-12-GH-P1-E1-S1

Converts pressure into a standard 4-20 mA output signal. Can be used to accurately measure compatible gases and liquids compatible with its 316/316L Stainless Steel wetted parts.

Converts pressure into a standard 4-20 mA output signal. Can be used to accurately measure compatible gases and liquids compatible with its 316/316L Stainless Steel wetted parts.

Prix spécial $786.78 CAD
Prix régulier $846.00 CAD
Disponibilité 2 à 3 semaines
Quantité

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre Dwyer IS626-12-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-200 psig)

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre Dwyer IS626-12-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-200 psig)

Dwyer IS626-12-GH-P1-E1-S1 PRESSURE TRANSMITTER, 0- 200 PSIG

  • Full scale accuracy is 0.25%.
  • Designed for industrial environments with a NEMA 4X (IP66) housing, this transmitter resists most effects of shock and vibration.
  • Models are available with a 3' cable or M-12 4 pin connection.

Specifications

Service: Compatible gases and liquids.
Wetted Materials: Type 316, 316L SS.
Accuracy: 0.25% full scale (includes linearity, hysteresis, and repeatability).
Temperature Limit: 0 to 176°F (-18 to 80°C).
Compensated Temperature Range: 0 to 176°F (-18 to 80°C).
Thermal Effect: ±0.02% FS/°F (includes zero and span).
Power Requirements: 10 to 28 VDC.
Output Signal: 4 to 20 mA.
Response Time: 50 msec.
Loop Resistance: 0-900 ohms maximum.
Current Consumption: 38 mA (maximum).
Electrical Connections: 3 ft. cable or 4-pin M-12 Connector.
Process Connection: 1/4" male/female NPT and BSPT.
Enclosure Rating: NEMA 4X (IP66).
Mounting Orientation: Mount in any position.
Weight: 8.9 oz (252 g).
Agency Approvals: CE, UL and cUL Intrinsically Safe to UL Standard 913.

For use in Hazardous (Classified) Locations:
Class I Div. 1 Groups A,B,C,D; Class II Div. 1 Groups E,F,G; Class III Div. 1.
Temperature Code: T4 @ 80°C ambient.
Install in accordance with control drawing 01-700797-00.
WARNING: To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing. Use with approved safety barriers using entity evaluation.

Le Dwyer IS626-12-GH-P1-E1-S1 comprend

  • Dwyer IS626-12-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-200 psig)

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Dwyer IS626-12-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-200 psig).

Dwyer MTL5041 Isolant galvanique sécuritaire intrinsèquement MTL5541
Provides total intrinsically safe isolation for communication with Dwyer® pressure transmitters approved for location in hazardous areas. Galvanic isolation eliminates the need for a high integrity earth ground required when using shunt diode type saf.




Dwyer MTL7706 Barrière de zener sécuritaire intrinsèquement MTL7706
Intrinsically safe (IS) shunt-diode barrier that can be used to communicate with and provide isolations for certain Dwyer® transmitters approved for use in hazardous areas. These barriers limit the amount of energy allowed to pass into the hazardous area, which inhibit ignition in flammable atmospheres.




Poser une question sur le Dwyer IS626-12-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-200 psig)

Dwyer IS626-12-GH-P1-E1-S1 PRESSURE TRANSMITTER, 0- 200 PSIG

  • Full scale accuracy is 0.25%.
  • Designed for industrial environments with a NEMA 4X (IP66) housing, this transmitter resists most effects of shock and vibration.
  • Models are available with a 3' cable or M-12 4 pin connection.

Specifications

Service: Compatible gases and liquids.
Wetted Materials: Type 316, 316L SS.
Accuracy: 0.25% full scale (includes linearity, hysteresis, and repeatability).
Temperature Limit: 0 to 176°F (-18 to 80°C).
Compensated Temperature Range: 0 to 176°F (-18 to 80°C).
Thermal Effect: ±0.02% FS/°F (includes zero and span).
Power Requirements: 10 to 28 VDC.
Output Signal: 4 to 20 mA.
Response Time: 50 msec.
Loop Resistance: 0-900 ohms maximum.
Current Consumption: 38 mA (maximum).
Electrical Connections: 3 ft. cable or 4-pin M-12 Connector.
Process Connection: 1/4" male/female NPT and BSPT.
Enclosure Rating: NEMA 4X (IP66).
Mounting Orientation: Mount in any position.
Weight: 8.9 oz (252 g).
Agency Approvals: CE, UL and cUL Intrinsically Safe to UL Standard 913.

For use in Hazardous (Classified) Locations:
Class I Div. 1 Groups A,B,C,D; Class II Div. 1 Groups E,F,G; Class III Div. 1.
Temperature Code: T4 @ 80°C ambient.
Install in accordance with control drawing 01-700797-00.
WARNING: To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing. Use with approved safety barriers using entity evaluation.

Le Dwyer IS626-12-GH-P1-E1-S1 comprend

  • Dwyer IS626-12-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-200 psig)

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le Dwyer IS626-12-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-200 psig).

Dwyer MTL5041 Isolant galvanique sécuritaire intrinsèquement MTL5541
Provides total intrinsically safe isolation for communication with Dwyer® pressure transmitters approved for location in hazardous areas. Galvanic isolation eliminates the need for a high integrity earth ground required when using shunt diode type saf.




Dwyer MTL7706 Barrière de zener sécuritaire intrinsèquement MTL7706
Intrinsically safe (IS) shunt-diode barrier that can be used to communicate with and provide isolations for certain Dwyer® transmitters approved for use in hazardous areas. These barriers limit the amount of energy allowed to pass into the hazardous area, which inhibit ignition in flammable atmospheres.




Poser une question sur le Dwyer IS626-12-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-200 psig)

Plus de produits Dwyer