Dwyer IEF Insertion Electromagnetic Flow Transmitter with LCD display, conduit connection

Modèle: IEF-SN-CND-COM-LCD

Dwyer IEF Insertion Electromagnetic Flow Transmitter with LCD display, conduit connection

Modèle: IEF-SN-CND-COM-LCD

An adjustable insertion flowmeter featuring electromagnetic technology to accurately and reliably measure fluid velocity, and provides several continuous signal outputs. Offers a standard accuracy of 1% FS, and comes equipped with an LCD display, and ½" female NPT conduit connection.

An adjustable insertion flowmeter featuring electromagnetic technology to accurately and reliably measure fluid velocity, and provides several continuous signal outputs. Offers a standard accuracy of 1% FS, and comes equipped with an LCD display, and ½" female NPT conduit connection.

Prix spécial $5570.70 CAD
Prix régulier $5990.00 CAD
Disponibilité 2 à 3 semaines
Quantité

Dwyer IEF-SN-CND-COM-LCD Offers

Features

  • Field configurable, integral or remote setup displays allow for ultimate flexibility by accommodating a variety of application configurations with one model through multiple display configurations i.e. pipe size, pipe material, liquid type, analog output, pulse/frequency output, alarm outputs, communication outputs, damping, and calibration factor
  • Setup Wizard and installation tool are simple to use allowing for quick and precise installation
  • Accessory setup kit A-IEF-KIT (sold separately) ensures exact installation application depth with included thickness gauge and measuring tape
  • Long Life Cycle and minimal maintenance requirements with no moving parts to wear or break and electrodes that discourage fouling
  • Isolation valve accessory options (sold separately) allow for installation in operational systems via hot-tap kit or easy removal without system downtime

Applications

  • Boiler feed water
  • Chilled water
  • Open and closed loop condenser water
  • Irrigation system
  • Municipal water distribution
  • Process and coolant flow
  • Ground water remediation
  • Chemical processing
  • Pump protection
  • Wastewater
  • Mining

Dwyer IEF-SN-CND-COM-LCD Specifications

Service Compatible clean or dirty non coating, conductive liquids
Range 0 to 20 ft/s (0 to 6 m/s)
Wetted Materials Body shaft/fitting: 316 SS
Electrodes: 316 SS
Electrode cap: Polymer/Polystyrene
O-ring: Silicon
Accuracy ±1% FS
Temperature Limits Ambient: -20 to 160°F (-29 to 71°C)
Process: 15 to 250°F (-9 to 121°C)
Storage: -40 to 185°F (-40 to 85°C)
Process Connection 1" NPT
Pressure Limits: 400 psi (27.6 bar) @ 100°F (37.8°C)
Drop: <0.1 psi at 12 ft/s in 4" (101.6 mm) and larger pipe
Outputs (1) Analog: 4 to 20 mA, 0 to 5 V, 0 to 10 V or 2 to 10 V (display selectable)
(1) Pulse/Frequency: 0 to 15 V peak pulse, 0 to 500 Hz or scalable pulse output (display selectable)
(2) Alarm: (1) Empty pipe detection or minimum/maximum velocity, (display selectable)
(1) Reverse flow output indication
Power Requirements 12 to 42.4 VDC, 0.25 A @ 24 VDC; 12 to 36 VAC
Display 2 x 2" (5.08 x 5.08 cm) graphic LCD with backlight
Conductivity >20 microsiemens
Enclosure Material: Powder coated die cast aluminum
Ratings: NEMA 4X (IP66)
Agency Approvals BTL, CE, NSF/ANSI 61 and 372
Cliquer ici pour toutes les spécifications du Dwyer IEF-SN-CND-COM-LCD

Le Dwyer IEF-SN-CND-COM-LCD comprend

  • Dwyer IEF Insertion Electromagnetic Flow Transmitter with LCD display, conduit connection

Poser une question sur le Dwyer IEF Insertion Electromagnetic Flow Transmitter with LCD display, conduit connection

Dwyer IEF-SN-CND-COM-LCD Offers

Features

  • Field configurable, integral or remote setup displays allow for ultimate flexibility by accommodating a variety of application configurations with one model through multiple display configurations i.e. pipe size, pipe material, liquid type, analog output, pulse/frequency output, alarm outputs, communication outputs, damping, and calibration factor
  • Setup Wizard and installation tool are simple to use allowing for quick and precise installation
  • Accessory setup kit A-IEF-KIT (sold separately) ensures exact installation application depth with included thickness gauge and measuring tape
  • Long Life Cycle and minimal maintenance requirements with no moving parts to wear or break and electrodes that discourage fouling
  • Isolation valve accessory options (sold separately) allow for installation in operational systems via hot-tap kit or easy removal without system downtime

Applications

  • Boiler feed water
  • Chilled water
  • Open and closed loop condenser water
  • Irrigation system
  • Municipal water distribution
  • Process and coolant flow
  • Ground water remediation
  • Chemical processing
  • Pump protection
  • Wastewater
  • Mining

Dwyer IEF-SN-CND-COM-LCD Specifications

Service Compatible clean or dirty non coating, conductive liquids
Range 0 to 20 ft/s (0 to 6 m/s)
Wetted Materials Body shaft/fitting: 316 SS
Electrodes: 316 SS
Electrode cap: Polymer/Polystyrene
O-ring: Silicon
Accuracy ±1% FS
Temperature Limits Ambient: -20 to 160°F (-29 to 71°C)
Process: 15 to 250°F (-9 to 121°C)
Storage: -40 to 185°F (-40 to 85°C)
Process Connection 1" NPT
Pressure Limits: 400 psi (27.6 bar) @ 100°F (37.8°C)
Drop: <0.1 psi at 12 ft/s in 4" (101.6 mm) and larger pipe
Outputs (1) Analog: 4 to 20 mA, 0 to 5 V, 0 to 10 V or 2 to 10 V (display selectable)
(1) Pulse/Frequency: 0 to 15 V peak pulse, 0 to 500 Hz or scalable pulse output (display selectable)
(2) Alarm: (1) Empty pipe detection or minimum/maximum velocity, (display selectable)
(1) Reverse flow output indication
Power Requirements 12 to 42.4 VDC, 0.25 A @ 24 VDC; 12 to 36 VAC
Display 2 x 2" (5.08 x 5.08 cm) graphic LCD with backlight
Conductivity >20 microsiemens
Enclosure Material: Powder coated die cast aluminum
Ratings: NEMA 4X (IP66)
Agency Approvals BTL, CE, NSF/ANSI 61 and 372
Cliquer ici pour toutes les spécifications du Dwyer IEF-SN-CND-COM-LCD

Le Dwyer IEF-SN-CND-COM-LCD comprend

  • Dwyer IEF Insertion Electromagnetic Flow Transmitter with LCD display, conduit connection

Poser une question sur le Dwyer IEF Insertion Electromagnetic Flow Transmitter with LCD display, conduit connection

Plus de produits Dwyer