Dwyer AVLV-1DB1 Series AVLV Air Velocity Transmitter, 1% accuracy, BACnet communication

Modèle: AVLV-1DB1

Dwyer AVLV-1DB1 Series AVLV Air Velocity Transmitter, 1% accuracy, BACnet communication

Modèle: AVLV-1DB1

The air velocity transmitter is used to measure air velocity and volumetric flow. It's duct mountable for precise placement.

The air velocity transmitter is used to measure air velocity and volumetric flow. It's duct mountable for precise placement.

Prix spécial $843.51 CAD
Prix régulier $907.00 CAD
Disponibilité 2 à 3 semaines
Quantité

Dwyer AVLV-1DB1 Offers



Monitor airflow in your VAV system, ductwork, clean room and other areas with the Dwyer AVLV-1DB1 Series AVLV Air Velocity Transmitter. Designed with coated sensors for lasting performance, this airflow transmitter is easy to connect to your monitoring equipment and can be mounted to your ductwork for precise placement. Thanks to BACnet MS/TP communication protocol, you can daisy-chain multiple units together for system-wide assessments.

Features

  • Used to measure air velocity and volumetric flow
  • Measures in imperial or metric units to suit your needs
  • Simultaneous current and voltage outputs make it easy to connect monitoring equipment
  • Local DIP switches let you configure output range, units and 0 to 5/10 VDC output
  • Coated sensors are made to last
  • Field-selectable ranges are easily configured without connecting power to the unit
  • Digital push buttons for zero and span adjustments
  • Enclosure is NEMA 4X (IP66) rated to ensure reliable durability
  • Duct mountable design
  • Humidity Limits: 5 to 95% RH, non-condensing
  • BACnet MS/TP communication protocol allows you to daisy-chain multiple units together, while providing access to all of the velocity/flow data and other information

Dwyer AVLV-1DB1 Specifications


ApplicationVAV systems, building ducts, clean room systems
Output Signal4 to 20 mA, 0 to 5 VDC, 0 to 10 VDC
Accuracy1%
ApprovalsBTL, CE
Product Weight6 oz (160 g)
Response Time4 seconds typical; 1 second at constant temperature
Operating Temperature32 to 122°F (0 to 50°C)
Power Requirements24 VDC ±20% or 24 VAC ±20%
Measuring MediumAir
Measuring ParametersAir Velocity
Loop ResistanceCurrent output: 0 to 1,100 Ω; voltage output: 1 kΩ
Current Consumption60 mA

Le Dwyer AVLV-1DB1 comprend

  • Dwyer AVLV-1DB1 Series AVLV Air Velocity Transmitter, 1% accuracy, BACnet communication

Poser une question sur le Dwyer AVLV-1DB1 Series AVLV Air Velocity Transmitter, 1% accuracy, BACnet communication

Dwyer AVLV-1DB1 Offers



Monitor airflow in your VAV system, ductwork, clean room and other areas with the Dwyer AVLV-1DB1 Series AVLV Air Velocity Transmitter. Designed with coated sensors for lasting performance, this airflow transmitter is easy to connect to your monitoring equipment and can be mounted to your ductwork for precise placement. Thanks to BACnet MS/TP communication protocol, you can daisy-chain multiple units together for system-wide assessments.

Features

  • Used to measure air velocity and volumetric flow
  • Measures in imperial or metric units to suit your needs
  • Simultaneous current and voltage outputs make it easy to connect monitoring equipment
  • Local DIP switches let you configure output range, units and 0 to 5/10 VDC output
  • Coated sensors are made to last
  • Field-selectable ranges are easily configured without connecting power to the unit
  • Digital push buttons for zero and span adjustments
  • Enclosure is NEMA 4X (IP66) rated to ensure reliable durability
  • Duct mountable design
  • Humidity Limits: 5 to 95% RH, non-condensing
  • BACnet MS/TP communication protocol allows you to daisy-chain multiple units together, while providing access to all of the velocity/flow data and other information

Dwyer AVLV-1DB1 Specifications


ApplicationVAV systems, building ducts, clean room systems
Output Signal4 to 20 mA, 0 to 5 VDC, 0 to 10 VDC
Accuracy1%
ApprovalsBTL, CE
Product Weight6 oz (160 g)
Response Time4 seconds typical; 1 second at constant temperature
Operating Temperature32 to 122°F (0 to 50°C)
Power Requirements24 VDC ±20% or 24 VAC ±20%
Measuring MediumAir
Measuring ParametersAir Velocity
Loop ResistanceCurrent output: 0 to 1,100 Ω; voltage output: 1 kΩ
Current Consumption60 mA

Le Dwyer AVLV-1DB1 comprend

  • Dwyer AVLV-1DB1 Series AVLV Air Velocity Transmitter, 1% accuracy, BACnet communication

Poser une question sur le Dwyer AVLV-1DB1 Series AVLV Air Velocity Transmitter, 1% accuracy, BACnet communication

Plus de produits Dwyer