Dwyer 645-11 Wet/Wet Differential Pressure Transmitter (-1-0-1 psid) with 0.25% Accuracy

Modèle: 645-11

Dwyer 645-11 Wet/Wet Differential Pressure Transmitter (-1-0-1 psid) with 0.25% Accuracy-


Télécharger: datasheet manual

Plus de produits Dwyer

Demander à un expert

Dwyer 645-11 Wet/Wet Differential Pressure Transmitter (-1-0-1 psid) with 0.25% Accuracy

Modèle: 645-11

Designed for use with compatible gases and liquids which can be applied to both the pressure and reference ports. Quick response capacitance sensor delivers a 4 to 20 mA output signal proportional to differential pressure with ±.25% accuracy.

Designed for use with compatible gases and liquids which can be applied to both the pressure and reference ports. Quick response capacitance sensor delivers a 4 to 20 mA output signal proportional to differential pressure with ±.25% accuracy.

Prix spécial $1585.65 CAD
Prix régulier $1705.00 CAD
Disponibilité 2 à 3 semaines
Quantité

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre Dwyer 645-11 Wet/Wet Differential Pressure Transmitter (-1-0-1 psid) with 0.25% Accuracy

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre Dwyer 645-11 Wet/Wet Differential Pressure Transmitter (-1-0-1 psid) with 0.25% Accuracy

Dwyer 645-11 PRESSURE TRANSMITTER, 1/0/1 PSID WET/WET

  • Designed for use with compatible gases and liquids which can be applied to both the pressure and reference ports.
  • Quick response capacitance sensor delivers a 4 to 20 mA output signal proportional to differential pressure with ±.25% accuracy.
  • Ideal for process control, filter condition monitoring, refrigeration equipment, pump speed control, HVAC/R equipment, and liquid level measurement.
  • For ease of installation and maintenance, order optional 3-valve manifold assembly.
  • Bleed ports allow for total elimination of air in the line and pressure cavities.

Specifications

Service: Compatible gases or liquids on both pressure and reference sides.
Wetted Materials: 17-4 PH stainless steel, 300 Series stainless steel, Fluoroelastomer and Silicone O-rings and bleed screw seals.
Accuracy: ±0.25% FS (RSS).
Temperature Limits: Operating: 0 to 175°F (-22 to 80°C), Storage: -65 to 260°F (-54 to 126°C).
Pressure Limits: (High side) 1 to 5 psi: 20 x FS, 10 to 25 psi: 10 x FS, 50 psi: 5 x FS, 100 psi: 2.5 x FS; (Low side) 2.5 x FS.
Thermal Effect: (Includes zero and span) ±0.02% FS/°F, 30 to 150°F (-1 to 65°C).
Power Requirements: 11 to 30 VDC.
Output Signal: 4 to 20 mA, 2-wire.
Zero and Span Adjustments: Adjustable, ±1 mA, non-interactive.
Response Time: 30 to 50 msec.
Loop Resistance: 0 to 1000 _.
Electrical Connection: Barrier strip terminal block with conduit enclosure and .875" (22 mm) diameter conduit opening.
Process Connection: 1/4" - 18 female NPT.
Housing: Stainless steel/aluminum, NEMA 4X (IP56).
Weight: 14.4 oz (0.4 kg).
Agency Approvals: CE.
3-Valve Manifold Assembly Manifold: Brass.
Valve Type: 90° On/Off.
Process Connection: 1/4" - 18 female NPT.

Dwyer 645-11 Specifications

3-Valve Manifold Assembly
Manifold Brass
Valve Type 90° on/off
Process Connection ¼" - 18 female NPT
General Specifications
Service Compatible gases or liquids on both pressure and reference sides
Wetted Materials 17-4 PH stainless steel
300 Series stainless steel
Fluoroelastomer
Silicone O-rings and bleed screw seals
Accuracy ±0.25% FS (RSS)
Temperature Limits Operating: 0 to 175°F (-22 to 80°C)
Storage: -65 to 260°F (-54 to 126°C)
Pressure Limits High side 1 to 5 psi: 20 x FS, 10 to 25 psi: 10 x FS, 50 psi: 5 x FS, 100 psi: 2.5 x FS
Low side: 2.5 x FS
Thermal Effects (Includes zero and span) ±0.02% FS/°F, 30 to 150°F (-1 to 65°C)
Power Requirements 11 to 30 VDC
Output Signal 4 to 20 mA, 2-wire
Zero and Span Adjustments Adjustable, ±1 mA, non-interactive
Response Time 30 to 50 ms
Loop Resistance 0 to 1000 Ω
Electrical Connection Barrier strip terminal block with conduit enclosure and 0.875" (22 mm) diameter conduit opening
Process Connection ¼" - 18 female NPT
Housing Stainless steel/aluminum, NEMA 4X (IP56)
Weight 14.4 oz (0.4 kg)
Agency Approvals CE
Cliquer ici pour toutes les spécifications du Dwyer 645-11

Le Dwyer 645-11 comprend

  • Dwyer 645-11 Wet/Wet Differential Pressure Transmitter (-1-0-1 psid) with 0.25% Accuracy

TPI 645 Dual Input Differential Manometer: Overview


This video will serve as an overview of the main features of this dual input differential manometer. Additionally, this instrument is ideal for industrial applications due to its range of up to 30 psi.

Poser une question sur le Dwyer 645-11 Wet/Wet Differential Pressure Transmitter (-1-0-1 psid) with 0.25% Accuracy

Dwyer 645-11 PRESSURE TRANSMITTER, 1/0/1 PSID WET/WET

  • Designed for use with compatible gases and liquids which can be applied to both the pressure and reference ports.
  • Quick response capacitance sensor delivers a 4 to 20 mA output signal proportional to differential pressure with ±.25% accuracy.
  • Ideal for process control, filter condition monitoring, refrigeration equipment, pump speed control, HVAC/R equipment, and liquid level measurement.
  • For ease of installation and maintenance, order optional 3-valve manifold assembly.
  • Bleed ports allow for total elimination of air in the line and pressure cavities.

Specifications

Service: Compatible gases or liquids on both pressure and reference sides.
Wetted Materials: 17-4 PH stainless steel, 300 Series stainless steel, Fluoroelastomer and Silicone O-rings and bleed screw seals.
Accuracy: ±0.25% FS (RSS).
Temperature Limits: Operating: 0 to 175°F (-22 to 80°C), Storage: -65 to 260°F (-54 to 126°C).
Pressure Limits: (High side) 1 to 5 psi: 20 x FS, 10 to 25 psi: 10 x FS, 50 psi: 5 x FS, 100 psi: 2.5 x FS; (Low side) 2.5 x FS.
Thermal Effect: (Includes zero and span) ±0.02% FS/°F, 30 to 150°F (-1 to 65°C).
Power Requirements: 11 to 30 VDC.
Output Signal: 4 to 20 mA, 2-wire.
Zero and Span Adjustments: Adjustable, ±1 mA, non-interactive.
Response Time: 30 to 50 msec.
Loop Resistance: 0 to 1000 _.
Electrical Connection: Barrier strip terminal block with conduit enclosure and .875" (22 mm) diameter conduit opening.
Process Connection: 1/4" - 18 female NPT.
Housing: Stainless steel/aluminum, NEMA 4X (IP56).
Weight: 14.4 oz (0.4 kg).
Agency Approvals: CE.
3-Valve Manifold Assembly Manifold: Brass.
Valve Type: 90° On/Off.
Process Connection: 1/4" - 18 female NPT.

Dwyer 645-11 Specifications

3-Valve Manifold Assembly
Manifold Brass
Valve Type 90° on/off
Process Connection ¼" - 18 female NPT
General Specifications
Service Compatible gases or liquids on both pressure and reference sides
Wetted Materials 17-4 PH stainless steel
300 Series stainless steel
Fluoroelastomer
Silicone O-rings and bleed screw seals
Accuracy ±0.25% FS (RSS)
Temperature Limits Operating: 0 to 175°F (-22 to 80°C)
Storage: -65 to 260°F (-54 to 126°C)
Pressure Limits High side 1 to 5 psi: 20 x FS, 10 to 25 psi: 10 x FS, 50 psi: 5 x FS, 100 psi: 2.5 x FS
Low side: 2.5 x FS
Thermal Effects (Includes zero and span) ±0.02% FS/°F, 30 to 150°F (-1 to 65°C)
Power Requirements 11 to 30 VDC
Output Signal 4 to 20 mA, 2-wire
Zero and Span Adjustments Adjustable, ±1 mA, non-interactive
Response Time 30 to 50 ms
Loop Resistance 0 to 1000 Ω
Electrical Connection Barrier strip terminal block with conduit enclosure and 0.875" (22 mm) diameter conduit opening
Process Connection ¼" - 18 female NPT
Housing Stainless steel/aluminum, NEMA 4X (IP56)
Weight 14.4 oz (0.4 kg)
Agency Approvals CE
Cliquer ici pour toutes les spécifications du Dwyer 645-11

Le Dwyer 645-11 comprend

  • Dwyer 645-11 Wet/Wet Differential Pressure Transmitter (-1-0-1 psid) with 0.25% Accuracy

TPI 645 Dual Input Differential Manometer: Overview


This video will serve as an overview of the main features of this dual input differential manometer. Additionally, this instrument is ideal for industrial applications due to its range of up to 30 psi.

Poser une question sur le Dwyer 645-11 Wet/Wet Differential Pressure Transmitter (-1-0-1 psid) with 0.25% Accuracy

Plus de produits Dwyer