This power quality analyzer set comes with 4 TR-2550B clamp-on current transformers that have a 1 to 100Arms measuring range and a 15mm diameter maximum conductor size.
This power quality analyzer set comes with 4 TR-2550B clamp-on current transformers that have a 1 to 100Arms measuring range and a 15mm diameter maximum conductor size.
Discontinué!
Ce produit a été discontinué et n’est plus disponible. Il n’y a pas de produit de remplacement direct. Ne vous inquiétez pas, nous avons quelques options pour vous aider à trouver ce dont vous avez besoin:
Visitez notre catégorie Compteurs à panneau pour trouver des produits similaires.
Ou nous ferons une recherche et vous aiderons à trouver ce dont vous avez besoin:
The HDPQ® Xplorer SP 400 is designed for commercial, military, aviation and naval industries requiring 400Hz capabilities that are not available in most power quality and energy analyzers. Designed with 400Hz applications in mind, it is also an all-purpose tool that can be used for any traditional 50/60Hz application.
Features
Applications
Measured Parameters | |
Differential Voltage Inputs (4) | 1 to 1000Vrms, AC/DC; ±0.1% rdg., <40V ±0.05% FS; 512 samples/cycle; 16-bit ADC resolution |
Current Inputs with CTs (4) | 10 to 100Arms AC; ±0.1% rdg. ±0.05% FS; 512 samples/cycle; 16-bit ADC resolution |
Frequency Range | 42.5 to 69Hz, ±0.01Hz, 380 to 420Hz ±0.1Hz |
Calculated Parameters | |
Vthd | 0 to 100%, ±5% for V ≥ 1% Vnom |
V Ind Harm | DC, 2 to 127, ±5% for V ≥ 1% Vnom |
Ithd | 0 to 100%, ±5% for V ≥ 1% Vnom |
I Ind Harm | DC, 2 to 63, ±5% for V ≥ 1% Vnom |
Pst | 10 minutes: 0.2 to 10, ±0.05 at Pst=1 |
Plt | 2 hours: 0.2 to 10, ±0.05 at Pst=1 |
General Specifications | |
Memory Size | 4GB |
Power Supply | 90 to 600VAC/500VDC (50/60Hz); powered by the phase being measured or other source |
Dimensions | 11 x 2.5 x 6.5in (27.9 x 6.4 x 16.5cm) |
Weight | 3.2lbs (1.45kg) |
Measured Parameters | |
Differential Voltage Inputs (4) | 1 to 1000Vrms, AC/DC; ±0.1% rdg., <40V ±0.05% FS; 512 samples/cycle; 16-bit ADC resolution |
Current Inputs with CTs (4) | 10 to 100Arms AC; ±0.1% rdg. ±0.05% FS; 512 samples/cycle; 16-bit ADC resolution |
Frequency Range | 42.5 to 69Hz, ±0.01Hz, 380 to 420Hz ±0.1Hz |
Calculated Parameters | |
Vthd | 0 to 100%, ±5% for V ≥ 1% Vnom |
V Ind Harm | DC, 2 to 127, ±5% for V ≥ 1% Vnom |
Ithd | 0 to 100%, ±5% for V ≥ 1% Vnom |
I Ind Harm | DC, 2 to 63, ±5% for V ≥ 1% Vnom |
Pst | 10 minutes: 0.2 to 10, ±0.05 at Pst=1 |
Plt | 2 hours: 0.2 to 10, ±0.05 at Pst=1 |
General Specifications | |
Memory Size | 4GB |
Power Supply | 90 to 600VAC/500VDC (50/60Hz); powered by the phase being measured or other source |
Dimensions | 11 x 2.5 x 6.5in (27.9 x 6.4 x 16.5cm) |
Weight | 3.2lbs (1.45kg) |