Digi-Sense 90452-66 Secondary Reference SPRT Probe with metal sheath, 1238°F, 100 ohm

Modèle: 90452-66 | No. de commande: WD-90452-66

Digi-Sense 90452-66 Secondary Reference SPRT Probe with metal sheath, 1238°F, 100 ohm

Modèle: 90452-66 | No. de commande: WD-90452-66

The AM1850 series reference SPRT probes is a state-of-the-art, high accuracy temperature monitoring from -328 to 1238°F. This 100 ohm probe features a sheath length and diameter of 19 x 0.25" and a spade lug for connections.

The AM1850 series reference SPRT probes is a state-of-the-art, high accuracy temperature monitoring from -328 to 1238°F. This 100 ohm probe features a sheath length and diameter of 19 x 0.25" and a spade lug for connections.

Discontinué!

Ce produit a été discontinué et n’est plus disponible. Il n’y a pas de produit de remplacement direct. Ne vous inquiétez pas, nous avons quelques options pour vous aider à trouver ce dont vous avez besoin:

Visitez notre catégorie DTR/PRT à usage général pour trouver des produits similaires.

Ou nous ferons une recherche et vous aiderons à trouver ce dont vous avez besoin:


Digi-Sense 90452-66 Offers

The standard platinum resistance thermometer probes with metal sheath offer state-of-the-art temperature monitoring. It meets ITS-90 standard for a reference thermometer often use in thermometer calibration and precision measurement in primary and secondary laboratories.

Digi-Sense 90452-66 Specifications

Probe Type Secondary Reference PRT/RTD
Temperature -328 to 1238°F (-200 to 670°C)
Temperature Accuracy ±0.003°C/100 hr at 0°C
Connector Type Spade Lug
Response Time 9 sec
Sheath Length 20"
Sheath Diameter 0.25"

Le Digi-Sense 90452-66 comprend

  • Digi-Sense 90452-66 Secondary Reference SPRT Probe with metal sheath, 1238°F, 100 ohm

Poser une question sur le Digi-Sense 90452-66 Secondary Reference SPRT Probe with metal sheath, 1238°F, 100 ohm

Digi-Sense 90452-66 Offers

The standard platinum resistance thermometer probes with metal sheath offer state-of-the-art temperature monitoring. It meets ITS-90 standard for a reference thermometer often use in thermometer calibration and precision measurement in primary and secondary laboratories.

Digi-Sense 90452-66 Specifications

Probe Type Secondary Reference PRT/RTD
Temperature -328 to 1238°F (-200 to 670°C)
Temperature Accuracy ±0.003°C/100 hr at 0°C
Connector Type Spade Lug
Response Time 9 sec
Sheath Length 20"
Sheath Diameter 0.25"

Le Digi-Sense 90452-66 comprend

  • Digi-Sense 90452-66 Secondary Reference SPRT Probe with metal sheath, 1238°F, 100 ohm

Poser une question sur le Digi-Sense 90452-66 Secondary Reference SPRT Probe with metal sheath, 1238°F, 100 ohm