Dent CT-SHS-0015-U Current Transformer

Modèle: CT-SHS-0015-U

Dent CT-SHS-0015-U Current Transformer

Modèle: CT-SHS-0015-U

Small High Accuracy Split Core Current Transformer. 15A.

Small High Accuracy Split Core Current Transformer. 15A.

Discontinué!

Ce produit a été discontinué et n’est plus disponible. Il n'y a aucune option de remplacement.

Nous pouvons vous aider à trouver ce dont vous avez besoin:


Dent CT-SHS-0015-U offre

These precision split core CTs are the perfect working solution to measure proportional line current on a medium voltage three phase circuit. Simply attach to the 5A secondary output of the existing medium voltage CTs. Connecting to the secondary isolates you from the hazards associated with the primary CT. No de-energizing or wire disconnection required.

Standard Features:

  • 0.5% of rated current
  • Phase Shift <0.5 degrees
  • ETL recognized per UL506
  • Excellent low current sensitivity

Spécifications pour le Dent CT-SHS-0015-U

Key Specifications
Window Size 1.0 cm (0.4")
Current Range .15‐20A AC
Output 333 mV @ rated current
Accuracy +/‐ 0.5% at 0.5% to 140% of rated current
Electrical
Output 333 mV
Phase Shift +/‐ 0.5° at rated current
Frequency Range 10 Hz to 10 KHz
Mechanical
Dimensions 6.4 x 2.5 x 5.1 cm (2.5 x 1.0 x 2.0")
Polarity White lead is positive
Output Lead 2.7 M (8'), twisted pair, 22 AWG
Operating Temperature –20° to 50°C (-4° to 122°F)
Other Features
Window Size 1.0 cm (0.4")
Weight 136 g (4.8 oz)
Dielectric Strength 5000V around the case, 600V rated leads
Storage Temperature Maximum 105°C (220°F)
Case Protection Plastic ABS/PVS or Epoxy encapsulated housing
Safety
Working Voltage 600 Vrms maximum
UL listed CAN/CSA‐C60044‐1‐2007 pts 1 & 2
CE Mark ANSI/IEEE C57.13, IEEE C57.13.2

Le Dent CT-SHS-0015-U comprend

  • Dent CT-SHS-0015-U Current Transformer

Poser une question sur le Dent CT-SHS-0015-U Current Transformer

Dent CT-SHS-0015-U offre

These precision split core CTs are the perfect working solution to measure proportional line current on a medium voltage three phase circuit. Simply attach to the 5A secondary output of the existing medium voltage CTs. Connecting to the secondary isolates you from the hazards associated with the primary CT. No de-energizing or wire disconnection required.

Standard Features:

  • 0.5% of rated current
  • Phase Shift <0.5 degrees
  • ETL recognized per UL506
  • Excellent low current sensitivity

Spécifications pour le Dent CT-SHS-0015-U

Key Specifications
Window Size 1.0 cm (0.4")
Current Range .15‐20A AC
Output 333 mV @ rated current
Accuracy +/‐ 0.5% at 0.5% to 140% of rated current
Electrical
Output 333 mV
Phase Shift +/‐ 0.5° at rated current
Frequency Range 10 Hz to 10 KHz
Mechanical
Dimensions 6.4 x 2.5 x 5.1 cm (2.5 x 1.0 x 2.0")
Polarity White lead is positive
Output Lead 2.7 M (8'), twisted pair, 22 AWG
Operating Temperature –20° to 50°C (-4° to 122°F)
Other Features
Window Size 1.0 cm (0.4")
Weight 136 g (4.8 oz)
Dielectric Strength 5000V around the case, 600V rated leads
Storage Temperature Maximum 105°C (220°F)
Case Protection Plastic ABS/PVS or Epoxy encapsulated housing
Safety
Working Voltage 600 Vrms maximum
UL listed CAN/CSA‐C60044‐1‐2007 pts 1 & 2
CE Mark ANSI/IEEE C57.13, IEEE C57.13.2