Dent CT-SCM-0400-U Medium Split Core Current Transformer, 400A

Modèle: CT-SCM-0400-U

Dent CT-SCM-0400-U Medium Split Core Current Transformer, 400A

Modèle: CT-SCM-0400-U

Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 1.25" and offers a 400A amp rating.

Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 1.25" and offers a 400A amp rating.

Prix spécial $120.96 CAD
Prix régulier $128.00 CAD
Disponibilité 1 Semaine
Quantité

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre CT-SCM-0400-U Medium Split Core Current Transformer

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre CT-SCM-0400-U Medium Split Core Current Transformer

Dent CT-SCM-0400-U offre

  • Gammes de courants spécifiées sont ensuite utilisées avec des mesureurs de puissance DENT compatibles
  • Transformateurs de courant RoCoil requièrent une alimentation pour utiliser avec d'autres mesureurs de 333 mV

Spécifications pour le Dent CT-SCM-0400-U

Key Specifications
Window Size 1.25" (3.20 cm)
Current Range 8 to 520A AC
Output 333 mV at rated current
Ratio Error <1% at rated current (typical)
Phase Error <2° at rated current (typical)
Electrical
Output 333 mV at rated current
Wire Polarity White = Hi, positive (+)
Black = Low, negative (-)
Frequency Range 50 to 400 Hz
Mechanical
Case Material Epoxy encapsulated housing
Leads 2.7 m (8'), twisted pair, 20 AWG
Operating Temperature -4 to 131°F (-20 to 55°C)

Le Dent CT-SCM-0400-U comprend

  • Dent CT-SCM-0400-U Medium Split Core Current Transformer, 400A

Poser une question sur le Dent CT-SCM-0400-U Medium Split Core Current Transformer, 400A

Dent CT-SCM-0400-U offre

  • Gammes de courants spécifiées sont ensuite utilisées avec des mesureurs de puissance DENT compatibles
  • Transformateurs de courant RoCoil requièrent une alimentation pour utiliser avec d'autres mesureurs de 333 mV

Spécifications pour le Dent CT-SCM-0400-U

Key Specifications
Window Size 1.25" (3.20 cm)
Current Range 8 to 520A AC
Output 333 mV at rated current
Ratio Error <1% at rated current (typical)
Phase Error <2° at rated current (typical)
Electrical
Output 333 mV at rated current
Wire Polarity White = Hi, positive (+)
Black = Low, negative (-)
Frequency Range 50 to 400 Hz
Mechanical
Case Material Epoxy encapsulated housing
Leads 2.7 m (8'), twisted pair, 20 AWG
Operating Temperature -4 to 131°F (-20 to 55°C)