Dent CT-RGT12-0100-U Revenue Grade Toroidal Solid Core Current Transformer, 100A

Modèle: CT-RGT19-0100-U

Dent CT-RGT12-0100-U Revenue Grade Toroidal Solid Core Current Transformer, 100A

Modèle: CT-RGT19-0100-U

Features a robust and compact design that is ideal for current measurement in panel boards, switchgear, and industrial control equipment. Designed to integrate into products which require an accurate signal transformation with low phase shift while exposed to harsh environmental operating conditions. Offers a 100A amp rating.

Features a robust and compact design that is ideal for current measurement in panel boards, switchgear, and industrial control equipment. Designed to integrate into products which require an accurate signal transformation with low phase shift while exposed to harsh environmental operating conditions. Offers a 100A amp rating.

Prix spécial $63.32 CAD
Prix régulier $67.00 CAD
Disponibilité 2 à 3 semaines
Quantité

Dent CT-RGT19-0100-U offre

Caractéristiques

  • Two termination options: 4ft twisted pair leads or PCB/pin outputs
  • Revenue grade performance meets or exceeds IEC 61869-2 Class 0.2, IEC 60044-1
  • Class 0.3, and IEEE C57.13 Class 0.3
  • Designed for use with PowerScout meters or OEM applications
  • UL Recognized
  • Unique snap, lock and tilt top

Applications

  • Panel boards
  • Switchgear
  • Industrial control equipment

Spécifications pour le Dent CT-RGT19-0100-U

Key Specifications
Window Size 0.75" (19 mm)
Current Range 1.0 to 100 A AC
Output 333.3 mV at rated current
Ratio Error ±0.2% at rated current (typical)
Phase Error <0.2°
Accuracy Class IEC 61869-2 Class 0.2
IEEE C57.13 Class 0.3
Lead 3 Meters
Electrical
Output 333.3 mV at rated current
Wire Polarity White = Hi, positive (+)
Black = Low, negative (-)
Frequency Range 50 to 400 Hz
Mechanical
Case Material PBT resin, UL 94V-0, epoxy encapsulated
Leads 8' (2.4 m), twisted pair, 24 AWG, 600V rated
Operating Temperature -13 to 185°F (-25 to 85°C)
Safety
Working Voltage 600 VAC, Category III
Dielectric Strength 5400 VAC
Certification Conforms to: UL STD 61010-1 EN 60044-1
Certified to: CAN/CSA STD C22.2 No. 61010-1

Le Dent CT-RGT19-0100-U comprend

  • Dent CT-RGT12-0100-U Revenue Grade Toroidal Solid Core Current Transformer, 100A

Poser une question sur le Dent CT-RGT12-0100-U Revenue Grade Toroidal Solid Core Current Transformer, 100A

Dent CT-RGT19-0100-U offre

Caractéristiques

  • Two termination options: 4ft twisted pair leads or PCB/pin outputs
  • Revenue grade performance meets or exceeds IEC 61869-2 Class 0.2, IEC 60044-1
  • Class 0.3, and IEEE C57.13 Class 0.3
  • Designed for use with PowerScout meters or OEM applications
  • UL Recognized
  • Unique snap, lock and tilt top

Applications

  • Panel boards
  • Switchgear
  • Industrial control equipment

Spécifications pour le Dent CT-RGT19-0100-U

Key Specifications
Window Size 0.75" (19 mm)
Current Range 1.0 to 100 A AC
Output 333.3 mV at rated current
Ratio Error ±0.2% at rated current (typical)
Phase Error <0.2°
Accuracy Class IEC 61869-2 Class 0.2
IEEE C57.13 Class 0.3
Lead 3 Meters
Electrical
Output 333.3 mV at rated current
Wire Polarity White = Hi, positive (+)
Black = Low, negative (-)
Frequency Range 50 to 400 Hz
Mechanical
Case Material PBT resin, UL 94V-0, epoxy encapsulated
Leads 8' (2.4 m), twisted pair, 24 AWG, 600V rated
Operating Temperature -13 to 185°F (-25 to 85°C)
Safety
Working Voltage 600 VAC, Category III
Dielectric Strength 5400 VAC
Certification Conforms to: UL STD 61010-1 EN 60044-1
Certified to: CAN/CSA STD C22.2 No. 61010-1

Le Dent CT-RGT19-0100-U comprend

  • Dent CT-RGT12-0100-U Revenue Grade Toroidal Solid Core Current Transformer, 100A

Poser une question sur le Dent CT-RGT12-0100-U Revenue Grade Toroidal Solid Core Current Transformer, 100A

Plus de produits Dent