B&K Precision 4013B 12 MHz DDS Sweep Function Generator

Modèle: 4013B | CUP: 817050401325

B&K Precision 4013B 12 MHz DDS Sweep Function Generator

Modèle: 4013B | CUP: 817050401325

Versatile, this sweep function generator features a sine and square frequency range from 0.1 Hz to 23 MHz and a triangle/ramp frequency range from 0.1 Hz to 1 MHz. With an advanced direct digital synthesis (DDS) design, this generator generates sine, square, and triangle waveforms with high signal precision and stability.

Versatile, this sweep function generator features a sine and square frequency range from 0.1 Hz to 23 MHz and a triangle/ramp frequency range from 0.1 Hz to 1 MHz. With an advanced direct digital synthesis (DDS) design, this generator generates sine, square, and triangle waveforms with high signal precision and stability.

Prix spécial $836.60 CAD
Prix régulier $940.00 CAD
Disponibilité 3 à 4 semaines
Quantité

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre 4013B 12 MHz DDS Sweep Function Generator

Traceable Calibration Certificate Icon

Certificat d’étalonnage de traçabilité pour votre 4013B 12 MHz DDS Sweep Function Generator

B&K Precision 4013B 12 MHz DDS Sweep Function Generator

Features

  • Sine and square waveforms up to 12 MHz
  • Bright easy-to-read display
  • Linear and logarithmic sweep
  • Variable DC offset
  • Adjustable duty cycle
  • Store and recall up to 9 instrument settings
  • Output On/Off button
  • Over-voltage, over-current, and short circuit protection on main output

B&K 4013B Specifications

Frequency
Sine 0.1 Hz to 12 MHz
Square 0.1 Hz to 12 MHz
Triangle 0.1 Hz to 1 MHz
Resolution 5 digits or 100 mHz
Accuracy 0.01% ±0.186 Hz
Output
Amplitude Range: 20 mVpp to 20 Vpp (open circuit)
10 mVpp to 10 Vpp (into 50 Ω)
Resolution: 3 digits (1000 counts)
Accuracy: ±2% ±20 mV of programmed output from 1.01 to 10 V
Flatness ±1 dB to 12 MHz
DC Offset Range: -4.5 to 4.5 V (into 50 Ω)
Resolution: 10 mV, 3 digits
Accuracy: ±2% ±10 mV (into 50 Ω)
Output Impedance: 50 Ω ±2%
Protection: Protected against short circuit or accidental over-voltage practically available in electronic laboratories, applied to the main output connector
Waveform
Harmonic Distortion (at 10 Vp-p into 50 Ω) DC - 100 kHz, -55 dBc
100 kHz - 1 MHz, < -45 dBc
1 MHz – 12 MHz, < -30 dBc
Square Rise/Fall Time ≤ 20 ns (10 to 90% at full amplitude into 50 Ω)
Duty Cycle Adjustable 20 to 80% up to 1 MHz for square and triangle
Symmetry Accuracy at 50% ±1%
Sweep
Shape Linear or Logarithmic, up or down
Time: 20 ms to 100 s
Input and Output
Sync Out TTL pulse at programmed frequency; 50 Ω source impedance
General Specifications
Memory Storage 9 instrument settings
Power Requirements 100 to 240 V AC ±10%
Temperature Operating: 32 to 122°F (0 to 50°C)
Storage: 14 to 158°F (-10 to 70°C)
Humidity 95% RH 32 to 86&def;F (0 to 30°C)
Dimensions 8.39 x 3.46 x 8.27" (213 x 88 x 210 mm)
Weight 4.4 lbs (2 kg)
Cliquer ici pour toutes les spécifications du B&K 4013B

What's included with the B&K 4013B

  • Sweep Function Generator
  • Certificate of Calibration
  • Power Cord

Poser une question sur le B&K Precision 4013B 12 MHz DDS Sweep Function Generator

B&K Precision 4013B 12 MHz DDS Sweep Function Generator

Features

  • Sine and square waveforms up to 12 MHz
  • Bright easy-to-read display
  • Linear and logarithmic sweep
  • Variable DC offset
  • Adjustable duty cycle
  • Store and recall up to 9 instrument settings
  • Output On/Off button
  • Over-voltage, over-current, and short circuit protection on main output

B&K 4013B Specifications

Frequency
Sine 0.1 Hz to 12 MHz
Square 0.1 Hz to 12 MHz
Triangle 0.1 Hz to 1 MHz
Resolution 5 digits or 100 mHz
Accuracy 0.01% ±0.186 Hz
Output
Amplitude Range: 20 mVpp to 20 Vpp (open circuit)
10 mVpp to 10 Vpp (into 50 Ω)
Resolution: 3 digits (1000 counts)
Accuracy: ±2% ±20 mV of programmed output from 1.01 to 10 V
Flatness ±1 dB to 12 MHz
DC Offset Range: -4.5 to 4.5 V (into 50 Ω)
Resolution: 10 mV, 3 digits
Accuracy: ±2% ±10 mV (into 50 Ω)
Output Impedance: 50 Ω ±2%
Protection: Protected against short circuit or accidental over-voltage practically available in electronic laboratories, applied to the main output connector
Waveform
Harmonic Distortion (at 10 Vp-p into 50 Ω) DC - 100 kHz, -55 dBc
100 kHz - 1 MHz, < -45 dBc
1 MHz – 12 MHz, < -30 dBc
Square Rise/Fall Time ≤ 20 ns (10 to 90% at full amplitude into 50 Ω)
Duty Cycle Adjustable 20 to 80% up to 1 MHz for square and triangle
Symmetry Accuracy at 50% ±1%
Sweep
Shape Linear or Logarithmic, up or down
Time: 20 ms to 100 s
Input and Output
Sync Out TTL pulse at programmed frequency; 50 Ω source impedance
General Specifications
Memory Storage 9 instrument settings
Power Requirements 100 to 240 V AC ±10%
Temperature Operating: 32 to 122°F (0 to 50°C)
Storage: 14 to 158°F (-10 to 70°C)
Humidity 95% RH 32 to 86&def;F (0 to 30°C)
Dimensions 8.39 x 3.46 x 8.27" (213 x 88 x 210 mm)
Weight 4.4 lbs (2 kg)
Cliquer ici pour toutes les spécifications du B&K 4013B

What's included with the B&K 4013B

  • Sweep Function Generator
  • Certificate of Calibration
  • Power Cord

Poser une question sur le B&K Precision 4013B 12 MHz DDS Sweep Function Generator