Designed for quick and easy operations, this phase and motor rotation meter services, repairs, and electrically maintains 3-phase systems and rotating machinery. Lightweight, robust, and compact, this meter can be used on 3-phase powered systems or 3-phase un-powered motors without any risk of damaging the tester.
Designed for quick and easy operations, this phase and motor rotation meter services, repairs, and electrically maintains 3-phase systems and rotating machinery. Lightweight, robust, and compact, this meter can be used on 3-phase powered systems or 3-phase un-powered motors without any risk of damaging the tester.
Discontinué!
Ce produit a été discontinué et n’est plus disponible. Il n’y a pas de produit de remplacement direct. Ne vous inquiétez pas, nous avons quelques options pour vous aider à trouver ce dont vous avez besoin:
Visitez notre catégorie Testeurs de phase et de rotations du moteur pour trouver des produits similaires.
Ou nous ferons une recherche et vous aiderons à trouver ce dont vous avez besoin:
Features
| Determination of the Phase Presence | |
| Nominal Voltage for Phase Presence Indication (the voltage required for the neon lamps L1, L2, L3 to lit up) | From 100 to 600 Vac |
| Frequency Range | From 10 to 400 Hz |
| Determination of the Phases Rotary Field Direction | |
| Direction (the voltage required to have the direction LEDs L1-L2-L3 or L2-L1-L3 to indicates) | From 1 to 600 Vac |
| Frequency Range | From 2 to 400 Hz |
| Determination of Motor Connections (Requires > ½ turn) | |
| Direction (the voltage required to have the direction LEDs L1-L2-L3 or L2-L1-L3 to indicates) | From 1 to 600 Vac |
| Frequency Range | From 2 to 400 Hz |
| Protection | |
| Over Load | 550 V (between all terminals) |
| Over Voltage | Class III - 600 V towards Ground |
| Fuses | 5 x 20 mm, 200 mA, 250 V fuse |
| General Specifications | |
| Battery | 9 V, IEC 6LR61 |
| Current Consumption | Maximum 18 mA |
| Display | Neon lamps and LEDs |
| Temperature Range | Operating: 5 to 131°F (-15 to 55°C) Storage: -4 to 158°F (-20 to 70°C) |
| Dimensions | 5.94 x 2.83 x 1.37" (151 x 72 x 35 mm) |
| Weight | 0.39 lbs (180 g) |
| Determination of the Phase Presence | |
| Nominal Voltage for Phase Presence Indication (the voltage required for the neon lamps L1, L2, L3 to lit up) | From 100 to 600 Vac |
| Frequency Range | From 10 to 400 Hz |
| Determination of the Phases Rotary Field Direction | |
| Direction (the voltage required to have the direction LEDs L1-L2-L3 or L2-L1-L3 to indicates) | From 1 to 600 Vac |
| Frequency Range | From 2 to 400 Hz |
| Determination of Motor Connections (Requires > ½ turn) | |
| Direction (the voltage required to have the direction LEDs L1-L2-L3 or L2-L1-L3 to indicates) | From 1 to 600 Vac |
| Frequency Range | From 2 to 400 Hz |
| Protection | |
| Over Load | 550 V (between all terminals) |
| Over Voltage | Class III - 600 V towards Ground |
| Fuses | 5 x 20 mm, 200 mA, 250 V fuse |
| General Specifications | |
| Battery | 9 V, IEC 6LR61 |
| Current Consumption | Maximum 18 mA |
| Display | Neon lamps and LEDs |
| Temperature Range | Operating: 5 to 131°F (-15 to 55°C) Storage: -4 to 158°F (-20 to 70°C) |
| Dimensions | 5.94 x 2.83 x 1.37" (151 x 72 x 35 mm) |
| Weight | 0.39 lbs (180 g) |