10
jours
23
heures
11
mins

Spécial pour la Saint-Jean-Baptiste - Soyez le premier à savoir les détails de cette promo
Spécial pour la Saint-Jean-Baptiste - Soyez le premier à savoir les détails de cette promo

Atago 3641 PRM-2000α In-Line Refractometer, 1.32 to 1.37 Refractive Index, 0 to 20% Brix Scale Range

Modèle: 3641 | No. de commande: PRM-2000alpha

Atago 3641 PRM-2000α In-Line Refractometer, 1.32 to 1.37 Refractive Index, 0 to 20% Brix Scale Range

Modèle: 3641 | No. de commande: PRM-2000alpha

Featuring a 0 to 20% Brix scale range, this in-line refractometer is ideal for the precision measurement of low-concentration samples, as well as fruit juices and other beverages.

Featuring a 0 to 20% Brix scale range, this in-line refractometer is ideal for the precision measurement of low-concentration samples, as well as fruit juices and other beverages.

Discontinué!

Ce produit a été discontinué et n’est plus disponible. Il n'y a aucune option de remplacement.

Nous pouvons vous aider à trouver ce dont vous avez besoin:


Spécifications pour le ATAGO 3641

Measurement Item Refractive index, Brix (Automatic temperature correction suitable for sucrose, high-fructose corn syrup and sugar-free (2% or less)), concentration (%) (temperature compensation according to samples), Temperature
Measurement Range Refractive Index nD 1.32069 to 1.365, Brix 0 to 20%
Resolution nD 0.00001, Brix 0.001%
Measurement Accuracy nD ±0.00001 (1.32069 to 1.33681), nD ±0.00010 (from 1.33682 up), Brix ±0.007% (0 to 2%), Brix ±0.050% (from 2.001% up); When measuring standard solutions under stable temperature condition
Measurement Temperature 32 to 212°F (0 to 100°C)
Temperature Control Range 41 to 194°F (5 to 90°C)
Wetted Parts Temperature Resistance -22 to 329°F (-30 to 165°C) during CIP/SIP (max 30 min)
Light Source LED (D-line approximation)
Materials in Contact with the Solution Prism: Sapphire, Prism stage: SUS316L
Prism Pressure Resistance 0.98mPa(10Kgf/cm2)
Display Item Refractive index, Brix (CH1 to 3), Concentration, Temperature (°C)
High and Low Limit Setting Open-collector output for high- and low-limit settings (Alarm output)
Output RS-232C, DC4 to 20mA
Output Item Refractive index or Brix (CH1 to 3) or Concentration, Temperature (°C)
Display System 7-segment LED
Alarm Output Open-collector output for high- and low-limit settings (alarm output)
Power Supply AC100V 50/60Hz
International Protection Class Detection section: IP67, Display section: IP67
Dimensions & Weight Detection section: 4.25 x 16.28 x 4.25in (10.8 x 41.35 x 10.8cm), 9.04lbs (4.1kg), Calculation Display section: 7.56 x 3.94 x 9.45in (19.2 x 10 x 24cm), 7.28lbs (3.3kg)
Power Consumption 30VA
Pressure Resistance 1.0mPa (Detection section)

Le ATAGO 3641 comprend

  • Atago 3641 PRM-2000α In-Line Refractometer, 1.32 to 1.37 Refractive Index, 0 to 20% Brix Scale Range

Poser une question sur le Atago 3641 PRM-2000α In-Line Refractometer, 1.32 to 1.37 Refractive Index, 0 to 20% Brix Scale Range

Spécifications pour le ATAGO 3641

Measurement Item Refractive index, Brix (Automatic temperature correction suitable for sucrose, high-fructose corn syrup and sugar-free (2% or less)), concentration (%) (temperature compensation according to samples), Temperature
Measurement Range Refractive Index nD 1.32069 to 1.365, Brix 0 to 20%
Resolution nD 0.00001, Brix 0.001%
Measurement Accuracy nD ±0.00001 (1.32069 to 1.33681), nD ±0.00010 (from 1.33682 up), Brix ±0.007% (0 to 2%), Brix ±0.050% (from 2.001% up); When measuring standard solutions under stable temperature condition
Measurement Temperature 32 to 212°F (0 to 100°C)
Temperature Control Range 41 to 194°F (5 to 90°C)
Wetted Parts Temperature Resistance -22 to 329°F (-30 to 165°C) during CIP/SIP (max 30 min)
Light Source LED (D-line approximation)
Materials in Contact with the Solution Prism: Sapphire, Prism stage: SUS316L
Prism Pressure Resistance 0.98mPa(10Kgf/cm2)
Display Item Refractive index, Brix (CH1 to 3), Concentration, Temperature (°C)
High and Low Limit Setting Open-collector output for high- and low-limit settings (Alarm output)
Output RS-232C, DC4 to 20mA
Output Item Refractive index or Brix (CH1 to 3) or Concentration, Temperature (°C)
Display System 7-segment LED
Alarm Output Open-collector output for high- and low-limit settings (alarm output)
Power Supply AC100V 50/60Hz
International Protection Class Detection section: IP67, Display section: IP67
Dimensions & Weight Detection section: 4.25 x 16.28 x 4.25in (10.8 x 41.35 x 10.8cm), 9.04lbs (4.1kg), Calculation Display section: 7.56 x 3.94 x 9.45in (19.2 x 10 x 24cm), 7.28lbs (3.3kg)
Power Consumption 30VA
Pressure Resistance 1.0mPa (Detection section)

Le ATAGO 3641 comprend

  • Atago 3641 PRM-2000α In-Line Refractometer, 1.32 to 1.37 Refractive Index, 0 to 20% Brix Scale Range

Poser une question sur le Atago 3641 PRM-2000α In-Line Refractometer, 1.32 to 1.37 Refractive Index, 0 to 20% Brix Scale Range

Plus de produits ATAGO