Used to trace live, de-energized, or open (broken) wires behind walls that are up to 13 feet (4m) thick, safe to use in data centers.
Used to trace live, de-energized, or open (broken) wires behind walls that are up to 13 feet (4m) thick, safe to use in data centers.
Discontinué!
Ce produit a été discontinué et n’est plus disponible.
Voici le produit de remplacement direct :
Caractéristiques
| General | |
| Operating Temperature | 0 to 120°F (-18°C to 49°C) |
| Storage Temperature | -40 to 150°F (-40° to 66°C) |
| Case Material | ABS |
| Case Size | 11" x 15.5" x 4" (39.4 x 27.9 x 10.2 cm) |
| R2000 Receiver | |
| Detectors | Electromagnetic coil pickup for short mode Electrostatic plate pickup for open mode |
| Sensitivity Selection | x1, x10, x100 course gain adjustment; 0-10 fine adjustment |
| Short Mode Performance | Over 20 feet in air under test conditions |
| Open Mode Performance | Over 12 feet in air under test conditions |
| 60Hz Rejection | 120 db |
| Power Source | 9V alkaline battery |
| Display | 10 LED's with chroma filter lens |
| S2600 Load Signal Generator | |
| Operating Voltage | 9-600 volts AC or DC |
| Operating Frequency | 32.768 KHz |
| Duty Cycle | Transmits 2 pulses with a duration of 0.0625 every 0.5 seconds |
| Current Output | Low mode: 35 mA peak, 4mA average High mode: 70 mA peal, 6mA average |
| Fuse | Fast acting 250mA @ 660V (6mm x 32mm)Cat. No. 660.25-6X32 |
| T2200 Transmitter | |
| Operating Frequency | 32.768 KHz |
| Duty Cycle | Transmits 2 pulses with a duration of 0.0625 every 0.5 seconds |
| Fuse | Fast acting 2A @ 250V 3AG .25" x 1.25" Cat No. 2502-6x32 |
| Battery | 9V alkaline - 24V jack will accept battery pack accessory (B2024 or B2025) |
| Signal Output | 9V supply / 24V supply |
| High Setting | 1A, 31V / 3A, 105V |
| Medium Setting | 1.8A, 13V / 6A, 45V |
| Low Setting | 3A, 6.5V / 10A, 22V |
| A2201 Clamp-on Transmitter Accessory | |
| Operating Frequency | 32.768 KHz as supplied by the T2200 |
| Case Breakdown Voltage | 3000 V |
| Maximum Wiresize | 2000 MCM or 2" dia. cable |
| General | |
| Operating Temperature | 0 to 120°F (-18°C to 49°C) |
| Storage Temperature | -40 to 150°F (-40° to 66°C) |
| Case Material | ABS |
| Case Size | 11" x 15.5" x 4" (39.4 x 27.9 x 10.2 cm) |
| R2000 Receiver | |
| Detectors | Electromagnetic coil pickup for short mode Electrostatic plate pickup for open mode |
| Sensitivity Selection | x1, x10, x100 course gain adjustment; 0-10 fine adjustment |
| Short Mode Performance | Over 20 feet in air under test conditions |
| Open Mode Performance | Over 12 feet in air under test conditions |
| 60Hz Rejection | 120 db |
| Power Source | 9V alkaline battery |
| Display | 10 LED's with chroma filter lens |
| S2600 Load Signal Generator | |
| Operating Voltage | 9-600 volts AC or DC |
| Operating Frequency | 32.768 KHz |
| Duty Cycle | Transmits 2 pulses with a duration of 0.0625 every 0.5 seconds |
| Current Output | Low mode: 35 mA peak, 4mA average High mode: 70 mA peal, 6mA average |
| Fuse | Fast acting 250mA @ 660V (6mm x 32mm)Cat. No. 660.25-6X32 |
| T2200 Transmitter | |
| Operating Frequency | 32.768 KHz |
| Duty Cycle | Transmits 2 pulses with a duration of 0.0625 every 0.5 seconds |
| Fuse | Fast acting 2A @ 250V 3AG .25" x 1.25" Cat No. 2502-6x32 |
| Battery | 9V alkaline - 24V jack will accept battery pack accessory (B2024 or B2025) |
| Signal Output | 9V supply / 24V supply |
| High Setting | 1A, 31V / 3A, 105V |
| Medium Setting | 1.8A, 13V / 6A, 45V |
| Low Setting | 3A, 6.5V / 10A, 22V |
| A2201 Clamp-on Transmitter Accessory | |
| Operating Frequency | 32.768 KHz as supplied by the T2200 |
| Case Breakdown Voltage | 3000 V |
| Maximum Wiresize | 2000 MCM or 2" dia. cable |