TSI/Alnor 41211 Flow Meter, 20L/min, Air, 1/4 inch Tube

Modèle: 41211

TSI/Alnor 41211 Flow Meter, 20L/min, Air, 1/4 inch Tube

Modèle: 41211

Fast 4 millisecond response ensures accuracy in fluctuating flows. This fast response is ideal for closed-loop control systems and integrated volume measurements.

Fast 4 millisecond response ensures accuracy in fluctuating flows. This fast response is ideal for closed-loop control systems and integrated volume measurements.

Discontinué!

Ce produit a été discontinué et n’est plus disponible.
Voici le produit de remplacement direct :

TSI Alnor 4140 Mass Flowmeter for Gases (Air, O<sub>2</sub>, N<sub>2</sub>) with LCD, 0.01 to 20 Std L/min, 0.25" Tube-

TSI Alnor 4140 Mass Flowmeter for Gases (Air, O2, N2) with LCD, 0.01 to 20 Std L/min, 0.25" Tube

Modèle: 4140

This mass flow meter can be used for a multitude of gas flow measurement applications.


TSI/Alnor 41211 offre

Caractéristiques

  • High accuracy ±2% of reading
  • High turndown ratio
  • Low pressure drop
  • Convenient analog output of flow rate
  • Versatile digital output of flow rate, volume, pressure, temperature
  • Built-in temperature and pressure compensation
  • NIST-traceable calibration certificate included at no additional cost

Applications

  • Product Development
  • Manufacturing
  • Research
  • Field Service
  • Quality Assurance

Spécifications pour le TSI/Alnor 41211

Gas Calibration Air
Inlet/Outlet Diameter 0.25" (6.4 mm)
Flow Measurement Range 0.01 to 20 Std L/min
Flow Measurement Accuracy (Air & O2) ±2% of reading or 0.005 Std L/min, whichever is greater
Flow Measurement Accuracy (N2) ±3% of reading or 0.010 Std L/min, whichever is greater
Flow Measurement Accuracy Response 4 ms to 63% of full scale flow
Overall Dimensions 5" x 2" x 1.25" (127 mm x 49 mm x 32 mm)
Recommended Filtration HEPA-grade

Le TSI/Alnor 41211 comprend

  • TSI 41211 Flow Meter
  • Analog and Digital Cable (mini-DIN to tinned wire)
  • Instructional Manual

Poser une question sur le TSI/Alnor 41211 Flow Meter, 20L/min, Air, 1/4 inch Tube

TSI/Alnor 41211 offre

Caractéristiques

  • High accuracy ±2% of reading
  • High turndown ratio
  • Low pressure drop
  • Convenient analog output of flow rate
  • Versatile digital output of flow rate, volume, pressure, temperature
  • Built-in temperature and pressure compensation
  • NIST-traceable calibration certificate included at no additional cost

Applications

  • Product Development
  • Manufacturing
  • Research
  • Field Service
  • Quality Assurance

Spécifications pour le TSI/Alnor 41211

Gas Calibration Air
Inlet/Outlet Diameter 0.25" (6.4 mm)
Flow Measurement Range 0.01 to 20 Std L/min
Flow Measurement Accuracy (Air & O2) ±2% of reading or 0.005 Std L/min, whichever is greater
Flow Measurement Accuracy (N2) ±3% of reading or 0.010 Std L/min, whichever is greater
Flow Measurement Accuracy Response 4 ms to 63% of full scale flow
Overall Dimensions 5" x 2" x 1.25" (127 mm x 49 mm x 32 mm)
Recommended Filtration HEPA-grade

Le TSI/Alnor 41211 comprend

  • TSI 41211 Flow Meter
  • Analog and Digital Cable (mini-DIN to tinned wire)
  • Instructional Manual

Poser une question sur le TSI/Alnor 41211 Flow Meter, 20L/min, Air, 1/4 inch Tube