AEMC MN82 AC Current Probe for the 6471 and 6472, 40A

Modèle: MN82 | No. de commande: 2135.71 | CUP: 685338139860

AEMC MN82 AC Current Probe for the 6471 and 6472, 40A

Modèle: MN82 | No. de commande: 2135.71 | CUP: 685338139860

Designed specifically for use with the AEMC 6471 and 6472 Ground Resistance Tester. When a single probe is used in conjunction with the traditional fall-all-potential method, selective grounds can be measured by moving the probe from point to point around the grounding system.

Designed specifically for use with the AEMC 6471 and 6472 Ground Resistance Tester. When a single probe is used in conjunction with the traditional fall-all-potential method, selective grounds can be measured by moving the probe from point to point around the grounding system.

Prix spécial $536.67 CAD
Prix régulier $603.00 CAD
Disponibilité 2 à 3 semaines
Quantité

Accessoires recommandées


AEMC MN82 Offers

When two MN82 probes are used in conjunction with the AEMC 6471 and 6472, grounding electrodes can be measured without the necessity of installing auxiliary rods and conducting a full potential measurement. This is also referred to as the stakeless method.

AEMC MN82 Specifications

Range and Resolution 0.00 to 9.99mA: 0.01mA
10.0 to 99.9mA: 0.1mA
100 to 999mA: 1mA
1.00 to 9.99A: 0.01A
10 to 40A: 0.1A
Frequency Range and Accuracy (0.5 to 100mA) 16 to 49Hz: ±(15% + 2cts)
50 to 99Hz: ±(7% + 2cts)
100 to 400Hz: ±(5% + 2cts)
Frequency Range and Accuracy (0.1 to 40A) 16 to 49Hz: > 20%
50 to 99Hz: ±(15% + 2cts)
100 to 400Hz: ±(7% + 2cts)
Cliquer ici pour toutes les spécifications du AEMC Instruments MN82

Le AEMC Instruments MN82 comprend

  • AEMC MN82 AC Current Probe for the 6471 and 6472, 40A

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le AEMC MN82 AC Current Probe for the 6471 and 6472, 40A.

AEMC 2952.70 Replacement Lead for the SR182 and MN82, 6ft 2952.70
Replacement 6 ft Extension Lead for use with the AEMC MN82 and SR182.




Poser une question sur le AEMC MN82 AC Current Probe for the 6471 and 6472, 40A

AEMC MN82 Offers

When two MN82 probes are used in conjunction with the AEMC 6471 and 6472, grounding electrodes can be measured without the necessity of installing auxiliary rods and conducting a full potential measurement. This is also referred to as the stakeless method.

AEMC MN82 Specifications

Range and Resolution 0.00 to 9.99mA: 0.01mA
10.0 to 99.9mA: 0.1mA
100 to 999mA: 1mA
1.00 to 9.99A: 0.01A
10 to 40A: 0.1A
Frequency Range and Accuracy (0.5 to 100mA) 16 to 49Hz: ±(15% + 2cts)
50 to 99Hz: ±(7% + 2cts)
100 to 400Hz: ±(5% + 2cts)
Frequency Range and Accuracy (0.1 to 40A) 16 to 49Hz: > 20%
50 to 99Hz: ±(15% + 2cts)
100 to 400Hz: ±(7% + 2cts)
Cliquer ici pour toutes les spécifications du AEMC Instruments MN82

Le AEMC Instruments MN82 comprend

  • AEMC MN82 AC Current Probe for the 6471 and 6472, 40A

Cliquer sur une catégorie pour voir une sélection d'accessoires compatible avec le AEMC MN82 AC Current Probe for the 6471 and 6472, 40A.

AEMC 2952.70 Replacement Lead for the SR182 and MN82, 6ft 2952.70
Replacement 6 ft Extension Lead for use with the AEMC MN82 and SR182.




Poser une question sur le AEMC MN82 AC Current Probe for the 6471 and 6472, 40A

Plus de produits AEMC Instruments