Additel 260Ex Series Reference Recorder, -15 to 600 psi, 0.02% FS, 1/4" NPT M

Modèle: ADT260EX-CP600-PSI-N

Additel 260Ex Series Reference Recorder, -15 to 600 psi, 0.02% FS, 1/4" NPT M

Modèle: ADT260EX-CP600-PSI-N

The 260Ex series is a very versatile and capable handheld device, being able to measure and collect data for pressure, temperature, barometric pressure and electrical measurement. This has a pressure range of -15 to 600 psi, an accuracy of 0.02% FS, and a 1/4" NPT male port.

The 260Ex series is a very versatile and capable handheld device, being able to measure and collect data for pressure, temperature, barometric pressure and electrical measurement. This has a pressure range of -15 to 600 psi, an accuracy of 0.02% FS, and a 1/4" NPT male port.

Votre prix $7991.00 CAD
Disponibilité 2 à 3 semaines
Quantité

Additel ADT260EX-CP600-PSI-N offre

Additel's 260Ex is an intrinsically safe handheld multichannel reference recorder with 8 different channel configurations. Armed with Additel’s most versatile and capable handheld, technicians are now able to measure and collect data for pressure, temperature (RTD probes available), barometric pressure and electrical measurement all in one highly portable device. The powerful logging capability and high-level of intrinsic safety make the ADT260Ex the perfect companion for use in the pipeline industry by supporting hydrostatic pressure testing, air leak testing, inlet and outlet pressure testing at pump stations, safety valve and ex-proof membrane testing, wellhead pressure testing, pipeline filter testing, differential pressure transmitter/flow computing testing, as well as routine calibration of pressure devices.

Intrinsically Safe:

The ADT260Ex has passed the most stringent ATEX, IECEX intrinsic safety certifications. Each unit complies with a certification level of Ex ia IIC T4 Ga. This highly qualified reference recorder can be widely used in potentially explosive gas environments, such as oil and gas platforms, refineries, chemical and petrochemical plants, pharmaceutical industry, energy and gas processing industry.

Datalogging Capabilities:

The Additel 260Ex includes a sizable built-in automatic recording capability which supports multi parameter logging, trend curve display, local curve observation and statistical feedback. The logged results are stored onboard and can be viewed locally. The data storage capacity is up to 10 million readings (single channel) with a logging interval that is configurable from 0.1s ~ 9999s.

8 Channel Combinations:

Channel 1: Built-in digital pressure module, field switchable

Channel 2: Built-in barometer, which can be calibrated by the user

Channels 3 and 4: External digital pressure module inputs

Channel 5: Simulated differential pressure channel synthesized using channels 3 and 4

Channels 6 and 7: Temperature measurement channels supporting resistance sensors with 2, 3 or 4 wires

Channel 8: Measures current, voltage, frequency, pulse or switch testing. Built-in loop power included.

Caractéristiques

  • Up to 8 measurement channels
  • Intrinsically safe
  • Field switchable pressure module
  • Data logging with real-time graphical trending
  • Supports hydrostatic testing
  • Color touchscreen display
  • Built-in barometer
  • Optional RTD probes available
  • Bluetooth and USB communication
  • Communicates with additel's link mobile app

Spécifications pour le Additel ADT260EX-CP600-PSI-N

Electrical
RTD Measurement Accuracy Range: 0 to 400 Ω
Accuracy: 0.01% RDG + 20 mΩ
Resolution: 1 mΩ
Note: Excitation current: 1 mA
Voltage Measurement Range: ±300 mV
Accuracy: 0.015% RDG + 1.5 mV
Resolution: 1 uV
Note: Impedance: >100 MΩ

Range: ±30 V
Accuracy: 0.015%RDG + 1.5 μA
Resolution: 0.1 mV
Note: Impedance: >1 MΩ
Current Measurement Range: ±30 mA
Accuracy: 0.015% RDG + 1.5 μA
Resolution: 0.1 uA
Note: Impedance: < 40 Ω
Frequency Measurement Range: 0.01 to 50000Hz (auto range)
Accuracy: 0.005% RDG + 2 last digit
Resolution: 6-digit auto-resolution
Note: Min threshold voltage: 2.5V
Units: Hz, kHz, MHz, CPM, CPH, s, ms, us
Switch On-Off Measurement Inspection voltage: (3 to 30)V
Response speed: < 10ms, support wet and dry switch
Pulse Count 0 to 9999999, optional rising edge and falling edge
Min threshold voltage: 2.5 V
Loop Power 22 V ± 10%, max output impedance: 320 Ω, max load current: 25 mA
Pressure
Pressure Range Range: -15 to 600 psi
Media: G, L
Accuracy: 0.02% FS
Burst Pressure: 3x
Pressure resolution 4, 5, or 6 digit resolution (user selectable)
Measurement Units kPa, Pa, GPa, MPa, mPa, uPa, hPa, bar, mbar, torr, mtorr, atm, psi, psia, psig, gf/cm2, kgf/cm2, inH2O@4°C, inH2O@68°F, mmH2O at 4°C, mmH2O at 20°C, ftH2O at 4°C, ftH2O at 68°F, inHg at 0°C, mmHg at 0°C, lb/ft2, tsi, psf, inH2O at 60°F, ftH2O at 60°F, cmH2O at 4°C, mH2O at 4°C, cmHg at 0°C, mHg at 0°C, kgf/m2
Temperature Compensation 14 to 122°F (-10 to 50°C)
Pressure Module Type Built-in digital pressure module: ADT158Ex (see ADT 158Ex datasheet for details)
External digital pressure module: ADT161Ex (see ADT 161Ex datasheet for details)
Specifications Refer to the technical specification of the ADT158Ex and ADT161Ex
High Static Pressure and Differential Pressure Synthesis Index Two modules must be with the same range;
Typical Differential pressure accuracy of 0.002% FS or 0.02% RD, whichever is greater when using two 0.02% FS external modules.
Typical Differential pressure accuracy of 0.002% FS or 0.05% RD, whichever is greater when using two 0.05% FS external modules.
General
RTD Measurement 2, 3, or 4 wire (user selectable). Unit measurement as°C,°F, K or ohms.
Filtering Average sliding filter (sample 1 to 50)
first-order linear filter (coefficient 0.01 to 1)
Switch The measurement value will be automatically displayed at the moment the switch changes state.
The latest 8 state changes will be saved in the memory.
Pressure Tare Tare value is set through the user interface
Pressure stability indicator Stability time and criteria is selectable
Power management Backlight auto off
Auto power off
Input Channel Top: 2 channels RTD measurement, 1 channel electric signal measurement, Φ4mm banana jacks
Right side: 2 channels for external digital pressure module, Lemo style connection
Bottom: embedded digital pressure module (model ADT158Ex) field switchable.
Internal: 1 embedded atmospheric pressure sensor
Barometric Accuracy ±55 Pa
Measurement Rate mV, V, mA & frequency and RTD: 3 times/sec
Pressure module: 1 to 10 times/sec selectable (3 as default)
Barometric: 1 times/sec
Data Storage Logging interval: from 0.1 to 9999 seconds, log up to 10 million readings (single channel)
Power 4000 mAh, 14.4 Wh explosion-proof intelligent lithium battery, charging time is 6 to 8 hours, the battery can be charged independently
Typical working time 100 hours (measurement mode)
Environmental Guaranteed temperature range of technical specifications: 14 to 122°F (-10 to 50°C)
*Temperature coefficient: ±5 ppm -4 to 14°F (-20 to -10°C)
Operating temperature: -4 to 122°F (-20 to 50°C)
Storage temperature range: -22 to 158°F(-30 to 70°C)
Humidity: 0 to 95% RH, non-condensing
Altitude: 9842.52' (3000 m)
Warm Up Time 10 minutes to fully meet technical specifications
Port Protection Voltage 30 V max
Explosion-proof Grade ATEX & IECEx: Ex ia IIC T4 Ga (Ta = -4 to 122°F (-20 to 50°C)
CE Certification TUV IEC61326, IEC61010
Rohs Compliance Rohs II Directive 2011/65/EU, EN50581:2012
Protection Level IP67, 1 meter drop test
Communication Isolate USB-TYPEC (slave), Bluetooth
Display 4.4 (11.18 cm) color display capacitive screen, transflective, with LED backlight
Warranty Time 1 year
Dimension 6.97 x 4.13 x 2.04 (177 x 105 x 52 mm) which does not include the bottom mount ADT158Ex if installed
Weight 1.65 lbs (0.75 kg)

Le Additel ADT260EX-CP600-PSI-N comprend

  • Multichannel Reference Recorder
  • ISO 17025 Accredited Calibration Certificate
  • 10 x Test Leads
  • Hanging Strap with Magnet
  • Ex USB Cable Type A to Type C
  • 110/220 V Power Adapter
  • Chargeable Li-Ion Battery
  • One-Year Warranty

Poser une question sur le Additel 260Ex Series Reference Recorder, -15 to 600 psi, 0.02% FS, 1/4" NPT M

Additel ADT260EX-CP600-PSI-N offre

Additel's 260Ex is an intrinsically safe handheld multichannel reference recorder with 8 different channel configurations. Armed with Additel’s most versatile and capable handheld, technicians are now able to measure and collect data for pressure, temperature (RTD probes available), barometric pressure and electrical measurement all in one highly portable device. The powerful logging capability and high-level of intrinsic safety make the ADT260Ex the perfect companion for use in the pipeline industry by supporting hydrostatic pressure testing, air leak testing, inlet and outlet pressure testing at pump stations, safety valve and ex-proof membrane testing, wellhead pressure testing, pipeline filter testing, differential pressure transmitter/flow computing testing, as well as routine calibration of pressure devices.

Intrinsically Safe:

The ADT260Ex has passed the most stringent ATEX, IECEX intrinsic safety certifications. Each unit complies with a certification level of Ex ia IIC T4 Ga. This highly qualified reference recorder can be widely used in potentially explosive gas environments, such as oil and gas platforms, refineries, chemical and petrochemical plants, pharmaceutical industry, energy and gas processing industry.

Datalogging Capabilities:

The Additel 260Ex includes a sizable built-in automatic recording capability which supports multi parameter logging, trend curve display, local curve observation and statistical feedback. The logged results are stored onboard and can be viewed locally. The data storage capacity is up to 10 million readings (single channel) with a logging interval that is configurable from 0.1s ~ 9999s.

8 Channel Combinations:

Channel 1: Built-in digital pressure module, field switchable

Channel 2: Built-in barometer, which can be calibrated by the user

Channels 3 and 4: External digital pressure module inputs

Channel 5: Simulated differential pressure channel synthesized using channels 3 and 4

Channels 6 and 7: Temperature measurement channels supporting resistance sensors with 2, 3 or 4 wires

Channel 8: Measures current, voltage, frequency, pulse or switch testing. Built-in loop power included.

Caractéristiques

  • Up to 8 measurement channels
  • Intrinsically safe
  • Field switchable pressure module
  • Data logging with real-time graphical trending
  • Supports hydrostatic testing
  • Color touchscreen display
  • Built-in barometer
  • Optional RTD probes available
  • Bluetooth and USB communication
  • Communicates with additel's link mobile app

Spécifications pour le Additel ADT260EX-CP600-PSI-N

Electrical
RTD Measurement Accuracy Range: 0 to 400 Ω
Accuracy: 0.01% RDG + 20 mΩ
Resolution: 1 mΩ
Note: Excitation current: 1 mA
Voltage Measurement Range: ±300 mV
Accuracy: 0.015% RDG + 1.5 mV
Resolution: 1 uV
Note: Impedance: >100 MΩ

Range: ±30 V
Accuracy: 0.015%RDG + 1.5 μA
Resolution: 0.1 mV
Note: Impedance: >1 MΩ
Current Measurement Range: ±30 mA
Accuracy: 0.015% RDG + 1.5 μA
Resolution: 0.1 uA
Note: Impedance: < 40 Ω
Frequency Measurement Range: 0.01 to 50000Hz (auto range)
Accuracy: 0.005% RDG + 2 last digit
Resolution: 6-digit auto-resolution
Note: Min threshold voltage: 2.5V
Units: Hz, kHz, MHz, CPM, CPH, s, ms, us
Switch On-Off Measurement Inspection voltage: (3 to 30)V
Response speed: < 10ms, support wet and dry switch
Pulse Count 0 to 9999999, optional rising edge and falling edge
Min threshold voltage: 2.5 V
Loop Power 22 V ± 10%, max output impedance: 320 Ω, max load current: 25 mA
Pressure
Pressure Range Range: -15 to 600 psi
Media: G, L
Accuracy: 0.02% FS
Burst Pressure: 3x
Pressure resolution 4, 5, or 6 digit resolution (user selectable)
Measurement Units kPa, Pa, GPa, MPa, mPa, uPa, hPa, bar, mbar, torr, mtorr, atm, psi, psia, psig, gf/cm2, kgf/cm2, inH2O@4°C, inH2O@68°F, mmH2O at 4°C, mmH2O at 20°C, ftH2O at 4°C, ftH2O at 68°F, inHg at 0°C, mmHg at 0°C, lb/ft2, tsi, psf, inH2O at 60°F, ftH2O at 60°F, cmH2O at 4°C, mH2O at 4°C, cmHg at 0°C, mHg at 0°C, kgf/m2
Temperature Compensation 14 to 122°F (-10 to 50°C)
Pressure Module Type Built-in digital pressure module: ADT158Ex (see ADT 158Ex datasheet for details)
External digital pressure module: ADT161Ex (see ADT 161Ex datasheet for details)
Specifications Refer to the technical specification of the ADT158Ex and ADT161Ex
High Static Pressure and Differential Pressure Synthesis Index Two modules must be with the same range;
Typical Differential pressure accuracy of 0.002% FS or 0.02% RD, whichever is greater when using two 0.02% FS external modules.
Typical Differential pressure accuracy of 0.002% FS or 0.05% RD, whichever is greater when using two 0.05% FS external modules.
General
RTD Measurement 2, 3, or 4 wire (user selectable). Unit measurement as°C,°F, K or ohms.
Filtering Average sliding filter (sample 1 to 50)
first-order linear filter (coefficient 0.01 to 1)
Switch The measurement value will be automatically displayed at the moment the switch changes state.
The latest 8 state changes will be saved in the memory.
Pressure Tare Tare value is set through the user interface
Pressure stability indicator Stability time and criteria is selectable
Power management Backlight auto off
Auto power off
Input Channel Top: 2 channels RTD measurement, 1 channel electric signal measurement, Φ4mm banana jacks
Right side: 2 channels for external digital pressure module, Lemo style connection
Bottom: embedded digital pressure module (model ADT158Ex) field switchable.
Internal: 1 embedded atmospheric pressure sensor
Barometric Accuracy ±55 Pa
Measurement Rate mV, V, mA & frequency and RTD: 3 times/sec
Pressure module: 1 to 10 times/sec selectable (3 as default)
Barometric: 1 times/sec
Data Storage Logging interval: from 0.1 to 9999 seconds, log up to 10 million readings (single channel)
Power 4000 mAh, 14.4 Wh explosion-proof intelligent lithium battery, charging time is 6 to 8 hours, the battery can be charged independently
Typical working time 100 hours (measurement mode)
Environmental Guaranteed temperature range of technical specifications: 14 to 122°F (-10 to 50°C)
*Temperature coefficient: ±5 ppm -4 to 14°F (-20 to -10°C)
Operating temperature: -4 to 122°F (-20 to 50°C)
Storage temperature range: -22 to 158°F(-30 to 70°C)
Humidity: 0 to 95% RH, non-condensing
Altitude: 9842.52' (3000 m)
Warm Up Time 10 minutes to fully meet technical specifications
Port Protection Voltage 30 V max
Explosion-proof Grade ATEX & IECEx: Ex ia IIC T4 Ga (Ta = -4 to 122°F (-20 to 50°C)
CE Certification TUV IEC61326, IEC61010
Rohs Compliance Rohs II Directive 2011/65/EU, EN50581:2012
Protection Level IP67, 1 meter drop test
Communication Isolate USB-TYPEC (slave), Bluetooth
Display 4.4 (11.18 cm) color display capacitive screen, transflective, with LED backlight
Warranty Time 1 year
Dimension 6.97 x 4.13 x 2.04 (177 x 105 x 52 mm) which does not include the bottom mount ADT158Ex if installed
Weight 1.65 lbs (0.75 kg)

Le Additel ADT260EX-CP600-PSI-N comprend

  • Multichannel Reference Recorder
  • ISO 17025 Accredited Calibration Certificate
  • 10 x Test Leads
  • Hanging Strap with Magnet
  • Ex USB Cable Type A to Type C
  • 110/220 V Power Adapter
  • Chargeable Li-Ion Battery
  • One-Year Warranty

Poser une question sur le Additel 260Ex Series Reference Recorder, -15 to 600 psi, 0.02% FS, 1/4" NPT M

Plus de produits Additel