Triplett PCAL300-NIST Loop Process Calibrator includes Traceable Calibration Certificate

Model: PCAL300-NIST | UPC: 614395005603

Triplett PCAL300-NIST Loop Process Calibrator includes Traceable Calibration Certificate

Model: PCAL300-NIST | UPC: 614395005603

Measuring DC voltage/current and source DC mA current with an accuracy of 0.02%, this process calibrator can simultaneously provide 24V loop power to transmitter while conducting mA current measurement. In addition, it features an adjustable 0-20mA/4-20mA span with % readout, automatic sawtooth or triangular output current step function, auto power off, and a built-in flashlight. This product includes a Traceable Calibration Certificate with full Data and Uncertainties.

Measuring DC voltage/current and source DC mA current with an accuracy of 0.02%, this process calibrator can simultaneously provide 24V loop power to transmitter while conducting mA current measurement. In addition, it features an adjustable 0-20mA/4-20mA span with % readout, automatic sawtooth or triangular output current step function, auto power off, and a built-in flashlight. This product includes a Traceable Calibration Certificate with full Data and Uncertainties.

Sale Price $1330.23 CAD
Regular Price $1529.00 CAD
Availability 2 to 3 Weeks
Quantity

Triplett PCAL300-NIST Offers

The Triplett PCAL300 Loop Process Calibrator for benchtop and field industrial process device testing and calibration features an adjustable 0-20mA/4-20mA span with % readout, automatic sawtooth or triangular output current step function, auto power off, and a built-in flashlight.

This product includes a Traceable Calibration Certificate with full Data and Uncertainties.

Features

  • Easily measure DC voltage/current and source DC mA current
  • Loop power: Simultaneously provides 24V loop power to transmitters while conducting mA current measurements
  • High accuracy: Source and measure accuracy up to 0.02%
  • Versatile current span adjustment: Easily adjust the current span from 0-20mA/4-20mA with percentage readout
  • Dynamic output functions: Choose between automatic sawtooth or triangular output current step functions
  • Built-in functions: Flashlight, Auto Power Off, Lo Battery Indicator

Applications

  • Process Instrumentation Calibration
  • Field Instrumentation Troubleshooting
  • Loop-Powered Transmitter Testing
  • Control Valve Calibration
  • PLC and DCS System Setup
  • Energy Management Systems
  • Field Maintenance and Commissioning
  • Building Automation Systems
  • Water and Wastewater Treatment
  • Renewable Energy Systems

Triplett PCAL300-NIST Specifications

Measurement
DC Voltage 30 V (0.001 V)
Accuracy: ±(0.02% + 2 mV)
DC Current 30 mA (0.001 mA)
Accuracy: ±(0.02% + 4μA)
Source
DC Current 30 mA (0.001 mA)
Accuracy: ±(0.05% + 4μA)
Loop Power 24 V
Accuracy: ±(10%)
General Specifications
Power 3 x AA batteries
Dimensions 7 x 3.5 x 2" (178 x 89 x 51 mm)
Weight 1 lbs (454 g)

What's included with the Triplett PCAL300-NIST

  • Process Calibrator
  • Traceable Calibration Certificate with full Data and Uncertainties
  • Test Leads
  • 4 x Spare Fuses
  • Latch Key (for opening battery door)
  • 3 x AA Batteries
  • One-Year Warranty

Ask a question about Triplett PCAL300-NIST Loop Process Calibrator

Customer Reviews for the Triplett PCAL300-NIST

Triplett PCAL300-NIST Offers

The Triplett PCAL300 Loop Process Calibrator for benchtop and field industrial process device testing and calibration features an adjustable 0-20mA/4-20mA span with % readout, automatic sawtooth or triangular output current step function, auto power off, and a built-in flashlight.

This product includes a Traceable Calibration Certificate with full Data and Uncertainties.

Features

  • Easily measure DC voltage/current and source DC mA current
  • Loop power: Simultaneously provides 24V loop power to transmitters while conducting mA current measurements
  • High accuracy: Source and measure accuracy up to 0.02%
  • Versatile current span adjustment: Easily adjust the current span from 0-20mA/4-20mA with percentage readout
  • Dynamic output functions: Choose between automatic sawtooth or triangular output current step functions
  • Built-in functions: Flashlight, Auto Power Off, Lo Battery Indicator

Applications

  • Process Instrumentation Calibration
  • Field Instrumentation Troubleshooting
  • Loop-Powered Transmitter Testing
  • Control Valve Calibration
  • PLC and DCS System Setup
  • Energy Management Systems
  • Field Maintenance and Commissioning
  • Building Automation Systems
  • Water and Wastewater Treatment
  • Renewable Energy Systems

Triplett PCAL300-NIST Specifications

Measurement
DC Voltage 30 V (0.001 V)
Accuracy: ±(0.02% + 2 mV)
DC Current 30 mA (0.001 mA)
Accuracy: ±(0.02% + 4μA)
Source
DC Current 30 mA (0.001 mA)
Accuracy: ±(0.05% + 4μA)
Loop Power 24 V
Accuracy: ±(10%)
General Specifications
Power 3 x AA batteries
Dimensions 7 x 3.5 x 2" (178 x 89 x 51 mm)
Weight 1 lbs (454 g)

What's included with the Triplett PCAL300-NIST

  • Process Calibrator
  • Traceable Calibration Certificate with full Data and Uncertainties
  • Test Leads
  • 4 x Spare Fuses
  • Latch Key (for opening battery door)
  • 3 x AA Batteries
  • One-Year Warranty