Measuring flow rate, totalized consumption, temperature, and operating pressure in a single instrument, this compressed air meter suits 2" (5 cm) line compressed air systems. Additionally, a TFT display shows three measurement values simultaneously and two 4 to 20 mA analog outputs support system integration. It uses the calorimetric measuring principle for accurate readings without pressure loss.
Measuring flow rate, totalized consumption, temperature, and operating pressure in a single instrument, this compressed air meter suits 2" (5 cm) line compressed air systems. Additionally, a TFT display shows three measurement values simultaneously and two 4 to 20 mA analog outputs support system integration. It uses the calorimetric measuring principle for accurate readings without pressure loss.
The testo 6454 compressed air meter enables you to carry out accurate compressed air consumption measurements, consumption and leak monitoring and flow measurements in your compressed air system. The compressed air meter can also be used to carry out a peak load analysis in order to determine whether you are generating compressed air of sufficient capacity. This creates transparency when it comes to compressed air consumption and can help you save energy, reduce costs and implement a targeted environmental management system (e.g. as per ISO 50001 or ISO 14001). Overall, these measures can help you find potential for savings or prevent unnecessary investment costs.
Features
Overview of the technical advantages offered by the testo 6454 compressed air meter
Measure four measurement parameters using just one instrument: Flow rate, totaliser, temperature, operating pressure
Applications
| Product Features | |
| Diameter | DN50 |
| Process Connection | Thread connection R 2" (5.08 cm) |
| Measurement Parameters | |
| Measuring Range (Flow-Through) | 40 to 11,670 l/min, 0.3 to 84 m/s, 2.5 to 700 m³/h |
| Temperature Coefficient | ±0.07% of measured value per K |
| Accuracy | Class 141: ±(2% of m.v. + 0.5% of f.v.); class 344: ±(6% of m.v. + 0.6% of f.v.); per ISO 8573-1:2010, at medium temperature 73°F (23°C) |
| Repeat Accuracy | 0.8% of m.v. + 0.2% of f.v. |
| Pressure Measuring Range | -1 to 16 bar |
| Temperature Measuring Range | 14 to 140°F (-10 to 60°C) |
| Display Range | 0 to 14,000 l/min, 0 to 100.8 m/s, 0 to 840 m³/h |
| Resolution | 10 l/min, 0.1 m/s, 0.5 m³/h |
| Inputs and Outputs | |
| Output Signal | 2x analog, 4 to 20 mA (scalable) |
| Maximum Load | 500 Ω |
| Operating Voltage | 18 to 30 V DC (per EN 50178 SELV/PELV) |
| Current Consumption | < 80 mA |
| General Specifications | |
| Display | Color display, 1.44", 128 x 128 pixel resolution |
| Ambient Temperature | 32 to 140°F (0 to 60°C) |
| Storage Temperature | -4 to 185°F (-20 to 85°C) |
| Humidity | < 90% RH (maximum permitted) |
| Protection Class | IP65; IP67 |
| Housing Material | PBT+PC-GF30, PPS GF40, stainless steel 1.4301/1.4305, galvanized steel 1.5523, brass 2.0401 (CW614N), FKM |
| Product Features | |
| Diameter | DN50 |
| Process Connection | Thread connection R 2" (5.08 cm) |
| Measurement Parameters | |
| Measuring Range (Flow-Through) | 40 to 11,670 l/min, 0.3 to 84 m/s, 2.5 to 700 m³/h |
| Temperature Coefficient | ±0.07% of measured value per K |
| Accuracy | Class 141: ±(2% of m.v. + 0.5% of f.v.); class 344: ±(6% of m.v. + 0.6% of f.v.); per ISO 8573-1:2010, at medium temperature 73°F (23°C) |
| Repeat Accuracy | 0.8% of m.v. + 0.2% of f.v. |
| Pressure Measuring Range | -1 to 16 bar |
| Temperature Measuring Range | 14 to 140°F (-10 to 60°C) |
| Display Range | 0 to 14,000 l/min, 0 to 100.8 m/s, 0 to 840 m³/h |
| Resolution | 10 l/min, 0.1 m/s, 0.5 m³/h |
| Inputs and Outputs | |
| Output Signal | 2x analog, 4 to 20 mA (scalable) |
| Maximum Load | 500 Ω |
| Operating Voltage | 18 to 30 V DC (per EN 50178 SELV/PELV) |
| Current Consumption | < 80 mA |
| General Specifications | |
| Display | Color display, 1.44", 128 x 128 pixel resolution |
| Ambient Temperature | 32 to 140°F (0 to 60°C) |
| Storage Temperature | -4 to 185°F (-20 to 85°C) |
| Humidity | < 90% RH (maximum permitted) |
| Protection Class | IP65; IP67 |
| Housing Material | PBT+PC-GF30, PPS GF40, stainless steel 1.4301/1.4305, galvanized steel 1.5523, brass 2.0401 (CW614N), FKM |