Megger 220005 5kV DC DielectricTest Set

Model: 220005

Megger 220005 5kV DC DielectricTest Set

Model: 220005

5 kV DC DielectricTest Set; 2.5 & 5 kV; 5 mA.

5 kV DC DielectricTest Set; 2.5 & 5 kV; 5 mA.

Regular Price $5788.00 CAD
Availability 2 to 3 Weeks
Quantity

Megger's 220005 5-kV Megohmmeter

Dielectric test sets measure leakage current while applying a dc voltage at or above the insulation system's operating level. This measurement aids in determining the insulation system's ability to withstand overvoltages such as lightning strikes and switching surges.


Applications

Megger portable dc dielectric test sets check the electrical insulation quality of motors, power cables, switchgear, insulators, transformers and capacitors. Typical applications include acceptance and maintenance testing of critical equipment used by electrical utility substations and industrial plant distribution systems. Power apparatus manufacturers may also use the equipment to perform QA/QC production tests.

The test sets can be used to perform step-voltage and proof tests which, when incorporated into a routine maintenance program, can aid in predicting potential failure before breakdown occurs.

Megger's 220005, a 5-kV unit for testing equipment is rated for 2.5 kV and below, and is suitable for testing power cable, switchgear and rotating machinery in accordance with IEEE, ICEA, NEMA and ANSI guidelines.

Because Megger dc dielectric test sets act like full-wave rectified units, they also are suitable for applications involving vacuum bottles.


DC vs AC High-potential Testing

Direct current high-potential testing provides several advantages over alternating current. Direct current test equipment uses far less power, provides fast charging of highly capacitive test samples, can be easily transported to the test site and costs less. Additionally, the dc test can detect incipient breakdown without the possibility of damage to good insulation.


What's Included

  • Ground connection cable, 10 ft [3 m]
  • kV/MΩ test record graph paper (100-sheet pad)
  • Power cord, Cat. No. 220015
  • Instruction manual

Key Features

  • Compact and portable
  • Air insulated, uses no oil
  • ±2% accuracy
  • Leakage current measurement as low as 0.1 mA
  • Continuously variable test voltage with zero-start safety interlock
  • Fast charging of high-capacitance samples
  • Current guard circuit for highly accurate measurements
  • Strip chart recorder for hard copies (optionally available)

Safety and Reliability

  • Input and output line circuit breaker
  • Output current overload relay
  • Zero-start interlock for high-voltage output
  • Switch control and indicating lights for high-voltage ON/OFF on the 15-kV model
  • Full circuit breaker protection

Specifications

Input 120 Vac, 50/60 Hz
Output Voltage: 0 to 15 kVdc, negative with respect to ground Current: 2 mA continuous Short Circuit: 12 mA max., limited by circuit breaker
Metering Kilovoltmeter: 4-in. (102-mm) taut band with two ranges, 0 to 7.5 and 0 to 15.0 kV Current Meter: 4-in. (102-mm) taut band with four ranges, 0 to 5/50/500 µA and 5 mA
Accuracy ±2% of full scale
Temperature Range 0 to 122° F (-17.7 to +50° C) operating

What's included with the Megger 220005

  • Megger 220005 5kV DC DielectricTest Set

Click on a category to view a selection of compatible accessories with the Megger 220005 5kV DC DielectricTest Set.

Megger CB101 Calibrated Check Box for 5 kV Megger Insulation Testers CB101
Suitable for checking the accuracy of insulation testers, this calibrated check box can measure a wide range of values with four resistors connected to the unit to check resistance readings with test voltages up to 5 kV DC. Get a calibration certificate with each check box showing the actual value of each resistance checkpoint.




Ask a question about Megger 220005 5kV DC DielectricTest Set

Customer Reviews for the Megger 220005

Megger's 220005 5-kV Megohmmeter

Dielectric test sets measure leakage current while applying a dc voltage at or above the insulation system's operating level. This measurement aids in determining the insulation system's ability to withstand overvoltages such as lightning strikes and switching surges.


Applications

Megger portable dc dielectric test sets check the electrical insulation quality of motors, power cables, switchgear, insulators, transformers and capacitors. Typical applications include acceptance and maintenance testing of critical equipment used by electrical utility substations and industrial plant distribution systems. Power apparatus manufacturers may also use the equipment to perform QA/QC production tests.

The test sets can be used to perform step-voltage and proof tests which, when incorporated into a routine maintenance program, can aid in predicting potential failure before breakdown occurs.

Megger's 220005, a 5-kV unit for testing equipment is rated for 2.5 kV and below, and is suitable for testing power cable, switchgear and rotating machinery in accordance with IEEE, ICEA, NEMA and ANSI guidelines.

Because Megger dc dielectric test sets act like full-wave rectified units, they also are suitable for applications involving vacuum bottles.


DC vs AC High-potential Testing

Direct current high-potential testing provides several advantages over alternating current. Direct current test equipment uses far less power, provides fast charging of highly capacitive test samples, can be easily transported to the test site and costs less. Additionally, the dc test can detect incipient breakdown without the possibility of damage to good insulation.


What's Included

  • Ground connection cable, 10 ft [3 m]
  • kV/MΩ test record graph paper (100-sheet pad)
  • Power cord, Cat. No. 220015
  • Instruction manual

Key Features

  • Compact and portable
  • Air insulated, uses no oil
  • ±2% accuracy
  • Leakage current measurement as low as 0.1 mA
  • Continuously variable test voltage with zero-start safety interlock
  • Fast charging of high-capacitance samples
  • Current guard circuit for highly accurate measurements
  • Strip chart recorder for hard copies (optionally available)

Safety and Reliability

  • Input and output line circuit breaker
  • Output current overload relay
  • Zero-start interlock for high-voltage output
  • Switch control and indicating lights for high-voltage ON/OFF on the 15-kV model
  • Full circuit breaker protection

Specifications

Input 120 Vac, 50/60 Hz
Output Voltage: 0 to 15 kVdc, negative with respect to ground Current: 2 mA continuous Short Circuit: 12 mA max., limited by circuit breaker
Metering Kilovoltmeter: 4-in. (102-mm) taut band with two ranges, 0 to 7.5 and 0 to 15.0 kV Current Meter: 4-in. (102-mm) taut band with four ranges, 0 to 5/50/500 µA and 5 mA
Accuracy ±2% of full scale
Temperature Range 0 to 122° F (-17.7 to +50° C) operating

What's included with the Megger 220005

  • Megger 220005 5kV DC DielectricTest Set

Click on a category to view a selection of compatible accessories with the Megger 220005 5kV DC DielectricTest Set.

Megger CB101 Calibrated Check Box for 5 kV Megger Insulation Testers CB101
Suitable for checking the accuracy of insulation testers, this calibrated check box can measure a wide range of values with four resistors connected to the unit to check resistance readings with test voltages up to 5 kV DC. Get a calibration certificate with each check box showing the actual value of each resistance checkpoint.




Ask a question about Megger 220005 5kV DC DielectricTest Set

Customer Reviews for the Megger 220005

More Megger Products