This is a high-performance handheld meter that offers true RMS voltage/current measurement, VFD measurement capability, temperature and frequency measurements, ideal for electrical troubleshooting, automation, and maintenance applications.
This is a high-performance handheld meter that offers true RMS voltage/current measurement, VFD measurement capability, temperature and frequency measurements, ideal for electrical troubleshooting, automation, and maintenance applications.
The AVO415 multimeter is for professional electricians, technicians, service personnel and engineers that require high reliability, build quality and performance in a compact, tough design. Suitable for applications where more than the basic digital multimeter functions are needed.
The AVO415 is a True RMS digital multimeter with variable frequency drive VDF voltage measurement. With a 6000 count high resolution display, IP67 rating for wet and dusty environments, and a CAT III 1000 V, CAT IV 600 V safety rating, it is designed for use in the most demanding applications.
Features
| Maximum Voltage | Between any terminal and earth ground: 1000 V |
| F1 Fuse Protection for A Inputs | 10 A, 1000 V, 30 kA |
| F2 Fuse Protection for mA Input | 800 mA, 1000 V, 30 kA |
| Battery Type | 9 V Alkaline, NEDA 1604A/IEC 6LR6 |
| Display | 6000 counts, backlit liquid crystal |
| Altitude | 6561.68 (2000 m) maximum |
| Operating Temperature | 41 to 104°F (5 to 40°C) |
| Storage Temperature | -4 to 140°F (20 to 60°C) |
| Operating Humidity | Max 80% up to 87°F (31°C), decreasing linearly to 50% at 104°F (40°C) |
| Storage Humidity | 50% at 104 °F (40 °C) |
| Safety | IEC 61010-1: Pollution Degree 2; IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V |
| EMC | IEC 61326-1: Portable Electromagnetic Environment, CISPR 11 Group 1, Class A, IEC 61326-2-2 Enclosure; Double moulded, IP67 rating |
| Shock (Drop Test) | 6.5' (2 m) |
| Continuity Check | Audible signal if resistance < 50 Ω; test current ≈0.35 mA |
| Diode Test | Test current 0 to 0.9 mA max; open circuit voltage 3.2 V DC typical |
| PEAK | Captures peaks > 1 ms |
| Temperature Sensor | Requires Type K thermocouple |
| Input Impedance | > 10 MΩ V DC and >10 MΩ V AC |
| Crest Factor | ≤3 at full scale up to 500 V, decreasing linearly to ≤ 1.5 at 1000 V |
| AC Response | True RMS |
| AC True RMS | The term stands for "Root-Mean-Square," which represents the method of calculation of the voltage or current value. Average responding multimeters are calibrated to read correctly only on sine waves, and they will read inaccurately on non-sine wave or distorted signals. True RMS meters read accurately on either type of signal. |
| ACV Bandwidth | 45 Hz to 1 kHz |
| Overrange Indication | OL is displayed |
| Auto Power OFF | 15 minutes (approximately) with disable feature |
| Polarity | Automatic (no indication for positive); Minus (-) sign for negative |
| Low Battery Indication | Battery low warning |
| Measurement Rate | 2 times per second |
| Dimensions | 7.09 x 3.23 x 2.17" (180 x 82 x 55 mm) |
| Weight | 0.88 lbs (397 g) without battery; 0.94 lbs (427 g) with battery |
| Maximum Voltage | Between any terminal and earth ground: 1000 V |
| F1 Fuse Protection for A Inputs | 10 A, 1000 V, 30 kA |
| F2 Fuse Protection for mA Input | 800 mA, 1000 V, 30 kA |
| Battery Type | 9 V Alkaline, NEDA 1604A/IEC 6LR6 |
| Display | 6000 counts, backlit liquid crystal |
| Altitude | 6561.68 (2000 m) maximum |
| Operating Temperature | 41 to 104°F (5 to 40°C) |
| Storage Temperature | -4 to 140°F (20 to 60°C) |
| Operating Humidity | Max 80% up to 87°F (31°C), decreasing linearly to 50% at 104°F (40°C) |
| Storage Humidity | 50% at 104 °F (40 °C) |
| Safety | IEC 61010-1: Pollution Degree 2; IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V |
| EMC | IEC 61326-1: Portable Electromagnetic Environment, CISPR 11 Group 1, Class A, IEC 61326-2-2 Enclosure; Double moulded, IP67 rating |
| Shock (Drop Test) | 6.5' (2 m) |
| Continuity Check | Audible signal if resistance < 50 Ω; test current ≈0.35 mA |
| Diode Test | Test current 0 to 0.9 mA max; open circuit voltage 3.2 V DC typical |
| PEAK | Captures peaks > 1 ms |
| Temperature Sensor | Requires Type K thermocouple |
| Input Impedance | > 10 MΩ V DC and >10 MΩ V AC |
| Crest Factor | ≤3 at full scale up to 500 V, decreasing linearly to ≤ 1.5 at 1000 V |
| AC Response | True RMS |
| AC True RMS | The term stands for "Root-Mean-Square," which represents the method of calculation of the voltage or current value. Average responding multimeters are calibrated to read correctly only on sine waves, and they will read inaccurately on non-sine wave or distorted signals. True RMS meters read accurately on either type of signal. |
| ACV Bandwidth | 45 Hz to 1 kHz |
| Overrange Indication | OL is displayed |
| Auto Power OFF | 15 minutes (approximately) with disable feature |
| Polarity | Automatic (no indication for positive); Minus (-) sign for negative |
| Low Battery Indication | Battery low warning |
| Measurement Rate | 2 times per second |
| Dimensions | 7.09 x 3.23 x 2.17" (180 x 82 x 55 mm) |
| Weight | 0.88 lbs (397 g) without battery; 0.94 lbs (427 g) with battery |