This advanced multifunction tester can perform all the testing required by IEC 364-6-61with one single instrument.
This advanced multifunction tester can perform all the testing required by IEC 364-6-61with one single instrument.
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
Features
Continuity and Insulation Testing
Loop and RCD Testing
| Continuity Testing | |
|---|---|
| Measuring Ranges | 20/200 Ω Autoranging |
| Open Circuit Voltage | 4 V |
| Short Circuit Current | 200 mA DC |
| Accuracy | ±(3%rdg+3dgt) |
| Insulation Testing | |
| Measuring Ranges | 20/200 Ω Autoranging |
| Test Voltage | 500V DC |
| Output Voltage on Open Circuit | 570 V DC ±6% |
| Rated Current | 1 mA |
| Accuracy | ±(3%rdg+3dgt) |
| Loop Impedance Testing | |
| Rated Voltage | 230V AC ±10% @ 50 Hz |
| Voltage Measuring Range | 100 to 250 V @ 50 Hz |
| Impedance Ranges | 20/2000 Ω |
| Nominal Test Current | 20 Ω Range: 24 A 2000 Ω Range: 15 mA |
| Accuracy | 20 Ω Range: ±(3%rdg+8dgt) 2000 Ω Range: ±(3%rdg+8dgt) |
| RCD Testing | |
| Rated Voltage | 230V AC ±10% @ 50 Hz |
| Trip Current Settings | RCD x 1/2: 5, 15, 50, 150, 250 mA RCD x 1: 10, 30,100,300,500 mA RCD Fast: 150 mA |
| Trip Current Duration | RCD x 1/2 x 1: 2000 ms RCD fast: 40 ms |
| Trip Current | ±3% of test current at 230 V |
| Trip time | ±(3%rdg+3dgt) |
| General Specifications | |
| Safety Standard | IEC 61010-1 CAT.Ⅲ 300V Pollution degree 2 |
| Withstand Voltage | 3700V AC for one minute |
| Continuity Testing | |
|---|---|
| Measuring Ranges | 20/200 Ω Autoranging |
| Open Circuit Voltage | 4 V |
| Short Circuit Current | 200 mA DC |
| Accuracy | ±(3%rdg+3dgt) |
| Insulation Testing | |
| Measuring Ranges | 20/200 Ω Autoranging |
| Test Voltage | 500V DC |
| Output Voltage on Open Circuit | 570 V DC ±6% |
| Rated Current | 1 mA |
| Accuracy | ±(3%rdg+3dgt) |
| Loop Impedance Testing | |
| Rated Voltage | 230V AC ±10% @ 50 Hz |
| Voltage Measuring Range | 100 to 250 V @ 50 Hz |
| Impedance Ranges | 20/2000 Ω |
| Nominal Test Current | 20 Ω Range: 24 A 2000 Ω Range: 15 mA |
| Accuracy | 20 Ω Range: ±(3%rdg+8dgt) 2000 Ω Range: ±(3%rdg+8dgt) |
| RCD Testing | |
| Rated Voltage | 230V AC ±10% @ 50 Hz |
| Trip Current Settings | RCD x 1/2: 5, 15, 50, 150, 250 mA RCD x 1: 10, 30,100,300,500 mA RCD Fast: 150 mA |
| Trip Current Duration | RCD x 1/2 x 1: 2000 ms RCD fast: 40 ms |
| Trip Current | ±3% of test current at 230 V |
| Trip time | ±(3%rdg+3dgt) |
| General Specifications | |
| Safety Standard | IEC 61010-1 CAT.Ⅲ 300V Pollution degree 2 |
| Withstand Voltage | 3700V AC for one minute |