Features

  • Developed for use in general industry and OEM applications, where versatility and economy are requirements
  • Compact stainless steel construction with ceramic sensor
  • Wide range of mechanical and electrical connections
  • ±0.5% accuracy
  • NEMA 4X / IP65 and IP67
  • CE, CSA and RoHS compliant
  • Approved for outdoor use
  • Customizable

Applications

  • HVAC/R
  • Refrigeration
  • Process and automation control
  • Hydraulics and pneumatic sensing
  • Pump and compressor monitoring

Winters LE360 Specifications

Range 0 to 60 psi
Over-Pressure 145 psi
Burst Pressure 218 psi
Output Signal Standard 2-wire: 4-20 mA / Vs = 8 to 32 V DC
Optional 3-wire: 0 to 10 V / Vs = 14-30 V DC
Optional 3-wire ratiometric: Vsig = 0.5-4.5 Vs / Vs = 5 ±0.5 V DC
Accuracy ±0.5% FSO
Permissible Load 2-wire: Rmax = [(Vs - Vs min) / 0.02] Ω
3-wire: Rmin = 10 kΩ
Influence Effects Supply: 0.05% FSO / 10 V
Load: 0.05% FSO / kΩ
Response Time 2-wire: <10 ms
3-wire: <3 ms
Measuring Rate 1 kHz
Thermal Error <±0.5% FSO / 10K
Permissible Temperatures Medium: -13 to 257°F (-25 to 125°C)
Electronics environment: -13 to 185°F (-25 to 85°C)
Storage: -40 to 185°F (-40 to 85°C)
Short-circuit Protection Permanent
3-wire ratiometric: None
Reverse Polarity Protection No damage. No function.
Electromagnetic Protection Emission and immunity according to EN 61326
Stability Vibration: 10 g, 25 Hz to 2 kHz according to DIN EN 60068-2-6
Shock: 500 g / 1 ms according to DIN EN 60068-2-27
Pollution Degree 4, electrical equipment for outdoor use
Pressure Port / Housing 304 SS
Current Consumption 2-wire: 25 mA max
3-wire voltage: 5 mA (short-circuit current 20 mA)
3-wire ratiometric: 1.5 mA
Long-term Stability <±0.3% FSO/year at reference conditions
Operation Life >100 x 106 cycles
Wetted Parts Seals: FKM
Diaphragm: Ceramic AI2 O3 96%
CE Conformity EMC directive: 2004/108/EC
Pressure equipment directive: 97/23/EC (module A)
Valid for devices with max permissible overpressure <3000 psi
Weight 0.2 lbs (120 g)
Click here for complete specifications on the Winters LE360

What's included with the Winters LE360

  • General Purpose Transmitter
  • 5-Year Warranty

Ask a question about Winters LE360 General Purpose Transmitter, 0 to 60 psi

Customer Reviews for the Winters LE360

Winters LE360 Offers

Features

  • Developed for use in general industry and OEM applications, where versatility and economy are requirements
  • Compact stainless steel construction with ceramic sensor
  • Wide range of mechanical and electrical connections
  • ±0.5% accuracy
  • NEMA 4X / IP65 and IP67
  • CE, CSA and RoHS compliant
  • Approved for outdoor use
  • Customizable

Applications

  • HVAC/R
  • Refrigeration
  • Process and automation control
  • Hydraulics and pneumatic sensing
  • Pump and compressor monitoring

Winters LE360 Specifications

Range 0 to 60 psi
Over-Pressure 145 psi
Burst Pressure 218 psi
Output Signal Standard 2-wire: 4-20 mA / Vs = 8 to 32 V DC
Optional 3-wire: 0 to 10 V / Vs = 14-30 V DC
Optional 3-wire ratiometric: Vsig = 0.5-4.5 Vs / Vs = 5 ±0.5 V DC
Accuracy ±0.5% FSO
Permissible Load 2-wire: Rmax = [(Vs - Vs min) / 0.02] Ω
3-wire: Rmin = 10 kΩ
Influence Effects Supply: 0.05% FSO / 10 V
Load: 0.05% FSO / kΩ
Response Time 2-wire: <10 ms
3-wire: <3 ms
Measuring Rate 1 kHz
Thermal Error <±0.5% FSO / 10K
Permissible Temperatures Medium: -13 to 257°F (-25 to 125°C)
Electronics environment: -13 to 185°F (-25 to 85°C)
Storage: -40 to 185°F (-40 to 85°C)
Short-circuit Protection Permanent
3-wire ratiometric: None
Reverse Polarity Protection No damage. No function.
Electromagnetic Protection Emission and immunity according to EN 61326
Stability Vibration: 10 g, 25 Hz to 2 kHz according to DIN EN 60068-2-6
Shock: 500 g / 1 ms according to DIN EN 60068-2-27
Pollution Degree 4, electrical equipment for outdoor use
Pressure Port / Housing 304 SS
Current Consumption 2-wire: 25 mA max
3-wire voltage: 5 mA (short-circuit current 20 mA)
3-wire ratiometric: 1.5 mA
Long-term Stability <±0.3% FSO/year at reference conditions
Operation Life >100 x 106 cycles
Wetted Parts Seals: FKM
Diaphragm: Ceramic AI2 O3 96%
CE Conformity EMC directive: 2004/108/EC
Pressure equipment directive: 97/23/EC (module A)
Valid for devices with max permissible overpressure <3000 psi
Weight 0.2 lbs (120 g)
Click here for complete specifications on the Winters LE360

What's included with the Winters LE360

  • General Purpose Transmitter
  • 5-Year Warranty

Ask a question about Winters LE360 General Purpose Transmitter, 0 to 60 psi