Veris HD3XVSTD Deluxe Duct Humidity Sensor, 3%, 0 to 5 V/0 to 10 VDC

Model: HD3XVSTD

Veris HD3XVSTD Deluxe Duct Humidity Sensor, 3%, 0 to 5 V/0 to 10 VDC

Model: HD3XVSTD

The humidity monitoring deluxe duct sensor is encased in die-cast metal housing for extra strength.

The humidity monitoring deluxe duct sensor is encased in die-cast metal housing for extra strength.

Discontinued!

This product has been discontinued and is no longer available.
This is the direct replacement:

Veris HD2XA2D Duct Relative Humidity Sensor-

Veris HD2XA2D Duct Relative Humidity Sensor

Model: HD2XA2D

The HD2XA2D is an all-in-one device combining humidity and temperature sensing. Intended for duct mount applications, the device ensures a building’s optimum temperature and humidity levels, resulting in greater energy efficiency.


Veris HD3XVSTD Offers

The humidity monitoring deluxe duct sensor is encased in die-cast metal housing for extra strength.

Features

  • Thin-film polymer capacitive sensor element recovers from 100% saturation
  • Replace element in the field to maintain accuracy and minimize downtime
  • Sensor element can be serviced without disturbing conduit
  • Polarity insensitive analog output provides flexible systems compatibility to save time in the field, and to stock fewer devices
  • HS element is microprocessor profiled with on-board nonvolatile memory

Applications

  • Managing Energy Systems
  • Controlling HVAC/R Systems for Improved Comfort and Energy Savings
  • Museums, Schools, Printing Shops and Other Locations Requiring Humidity Control
  • Facilitating Compliance with ASHRAE Standards for Environmental Control and Indoor Air Quality

Veris HD3XVSTD Specifications

HS Element Digitally profiled thin-film capacitive (32-bit mathematics) U.S. Patent 5,844,138
Accuracy ±1% (multi-point calibration, NIST traceable) at 77°F (25°C) from 10 to 80% RH
Reset Rate 24 hours
Stability ±1% at 68°F (20°C) annually, for 2 years
Operating Humidity Range 0 to 100% RH (non-condensing)
Hysteresis 1.5% typical
Temperature Effect ±0.1% RH/°C above or below 77°F (25°C) (typical)
Analog Output 4 to 20 mA mode: 2-wire, polarity insensitive (clipped and capped)
Scaling 0 to 100% RH
Operating Temperature Range -40 to 122°F (-40 to 50°C)
Input Power Loop powered 12 to 30 VDC only, 30 mA max
Temperature Transmitter Output Digital, 4 to 20 mA (clipped and capped) or 0 to 5 V/0 to 10 V output; accuracy ±1°F (±0.5°C) typical
Click here for complete specifications on the Veris HD3XVSTD

What's included with the Veris HD3XVSTD

  • Veris HD3XVSTD Deluxe Duct Humidity Sensor, 3%, 0 to 5 V/0 to 10 VDC

Ask a question about Veris HD3XVSTD Deluxe Duct Humidity Sensor, 3%, 0 to 5 V/0 to 10 VDC

Customer Reviews for the Veris HD3XVSTD

Veris HD3XVSTD Offers

The humidity monitoring deluxe duct sensor is encased in die-cast metal housing for extra strength.

Features

  • Thin-film polymer capacitive sensor element recovers from 100% saturation
  • Replace element in the field to maintain accuracy and minimize downtime
  • Sensor element can be serviced without disturbing conduit
  • Polarity insensitive analog output provides flexible systems compatibility to save time in the field, and to stock fewer devices
  • HS element is microprocessor profiled with on-board nonvolatile memory

Applications

  • Managing Energy Systems
  • Controlling HVAC/R Systems for Improved Comfort and Energy Savings
  • Museums, Schools, Printing Shops and Other Locations Requiring Humidity Control
  • Facilitating Compliance with ASHRAE Standards for Environmental Control and Indoor Air Quality

Veris HD3XVSTD Specifications

HS Element Digitally profiled thin-film capacitive (32-bit mathematics) U.S. Patent 5,844,138
Accuracy ±1% (multi-point calibration, NIST traceable) at 77°F (25°C) from 10 to 80% RH
Reset Rate 24 hours
Stability ±1% at 68°F (20°C) annually, for 2 years
Operating Humidity Range 0 to 100% RH (non-condensing)
Hysteresis 1.5% typical
Temperature Effect ±0.1% RH/°C above or below 77°F (25°C) (typical)
Analog Output 4 to 20 mA mode: 2-wire, polarity insensitive (clipped and capped)
Scaling 0 to 100% RH
Operating Temperature Range -40 to 122°F (-40 to 50°C)
Input Power Loop powered 12 to 30 VDC only, 30 mA max
Temperature Transmitter Output Digital, 4 to 20 mA (clipped and capped) or 0 to 5 V/0 to 10 V output; accuracy ±1°F (±0.5°C) typical