UEi C165+NOILKIT Residential/Commercial Combustion Analyzer Kit with NOx sensor and smoke pump test kit, 32 to 1112°F, 2000 ppm

Model: C165+NOILKIT | UPC: 053533509229

UEi C165+NOILKIT Residential/Commercial Combustion Analyzer Kit with NOx sensor and smoke pump test kit, 32 to 1112°F, 2000 ppm

Model: C165+NOILKIT | UPC: 053533509229

Ideal for combustion analysis, this flue gas analyzer with NOx sensor offers essential information for installing and maintaining gas/oil-fired appliances, and the LINK feature connects wireless probes. This kit includes a flue probe, wireless pipe clamp probes, K-type thermocouples, a smoke pump test kit, and an IR thermal printer.

Ideal for combustion analysis, this flue gas analyzer with NOx sensor offers essential information for installing and maintaining gas/oil-fired appliances, and the LINK feature connects wireless probes. This kit includes a flue probe, wireless pipe clamp probes, K-type thermocouples, a smoke pump test kit, and an IR thermal printer.

Discontinued!

This product has been discontinued and is no longer available.

There is no direct replacement, however we recommend the:

Kane KANE458SNOOILKIT Flue Gas Analyzer with NOX and oil service kit-

Kane KANE458SNOOILKIT Flue Gas Analyzer with NOX and oil service kit

Model: KANE458SNOOILKIT

Capable of testing domestic gas, oil, biomass, and some commercial appliances, this flue gas analyzer kit comes with a NO sensor and oil service kit. In addition, it comes with the latest upgradeable sensor technology and has a protective rubber cover with magnets for "hands-free" operation.


Not what you're looking for? Let’s do a search and help you find what you need.


Recommended Accessories

UEi AC509 Hard Carrying Case-

UEi C165+NOILKIT Offers

Features

  • Large 6-line backlit display
  • LINK to wireless probes
  • Wireless flow and return probes
  • NOx filtered and H2 compensated CO sensor (10,000 ppm range)
  • Over-range protection pump
  • NOx filtered CO sensor
  • Room CO test
  • Differential pressure
  • Heat exchanger test
  • Four types of sensor protection
  • Low flow detection to protect reading accuracy
  • High altitude compensation
  • Temperature differential with K-type probe inputs
  • Protective water trap
  • Wireless connection to a free printer App (iOS® and Android™ compatible)
  • Eight pre-programmed fuels
  • Protective rubber boot with magnet
  • DMM-style rotary dial

Functions

  • Measures: Flue gas smoke, NO, CO (10,000 ppm H2 compensated), CO2, differential pressure, flue and inlet temperature
  • Calculates: Differential temperature, efficiency (net, gross), excess air

Applications

  • Residential and commercial combustion analysis
  • Installing and maintaining gas/oil-fired applicances

UEi C165+NOILKIT Specifications

Temperature Measurement
Flue Temperature Range: 32 to 1112°F (0 to 600°C)
Resolution: 0.1°F (0.1°C)
Accuracy: ±(0.3% rdg +3.6°F [2°C])
Inlet Temperature (Internal Sensor) Range: 32 to 122°F (0 to 50°C)
Resolution: 0.1°F (0.1°C)
Accuracy: +1.8°C +0.3% rdg
Inlet Temperature (External Sensor) Range: 32 to 1112°F (0 to 600°C)
Resolution: 0.1° (0.1°C)
Accuracy: +3.6°F +0.3% rdg
Flue Gas Measurement
Oxygen Range: 0 to 21%
Resolution: 0.1%
Accuracy: +0.3% volume
Carbon Monoxide Range: 0 to 2000 ppm; 2000 to 9999 ppm; above 9999 pm
Resolution: 1 ppm
Accuracy: ±3 ppm or ±5% rdg; ±10% of rdg; unspecified
Carbon Dioxide Range: 0 to 20%
Resolution: 0.1%
Accuracy: 0.3% rdg
Efficiency (Net or Gross) Range: 0 to 99.9%
Resolution: 0.1%
Accuracy: +1% rdg
Efficiency High (C) Range: 0 to 119.9%
Resolution: 0.1%
Accuracy: +1% rdg
Excess Air Range: 0 to 250%
Resolution: 0.1%
Accuracy: +0.2% rdg
CO/CO2 Ratio Range: 0 to 0.9999%
Resolution: 0.0001
Accuracy: +5% rdg
Nitric Oxide Sensor Range: 0 to 100 ppm; overrange to 1500 ppm
Resolution: 1 ppm
Accuracy: + 2 ppm <30 ppm; +5 ppm <100 ppm; +5% reading >100 ppm
Pressure (Differential)
Range ±80 mbar
Resolution 0.1 mbar
Accuracy ±0.5% FSD
General Specifications
Pre-Programmed Fuels Natural gas, propane, butane, LPG, light oils (28/35 seconds), wood pellets, town gas, coke
Environmental Conditions Operating temperature: 32 to 112°F (0 to 45°C)
Storage temperature: 0 to 120°F (-18 to 50°C)
Humidity: 10 to 90% RH
Certification CE Conformity, RoHS, REACH Compliant, AHRI 1260 standard, FCC
Dimensions 7.87 x 1.77 x 3.5" (200 x 44.9 x 88.9 mm)
Weight 1.38 lbs (0.63 kg)
Click here for complete specifications on the UEi C165+NOILKIT

What's included with the UEi C165+NOILKIT

  • Combustion Analyzer
  • Flue Gas Probe
  • 2 x Wireless Pipe Clamp Probes
  • 2 x K-Type Thermocouples
  • Smoke Pump Test Kit
  • IR Thermal Printer
  • Spare Printer Paper Roll
  • Particle Filter
  • Tubing with Connector
  • Carrying Case
  • 3 x AA Rechargeable Batteries
  • USB Charging Cable
  • Quick Start Guide
  • 10-Year Warranty

Click on a category to view a selection of compatible accessories with the UEi C165+NOILKIT Residential/Commercial Combustion Analyzer Kit with NOx sensor and smoke pump test kit, 32 to 1112°F, 2000 ppm.

UEi AC509 Hard Carrying Case AC509
UEi AC509 hard sided blow-molded case for the eagle & eagle x combustion analyzers protective compartment for analyzer, printer and accessories flue probe storage separated from analyzer to protect the instrument size 19"w x 14"h x 3-1/2"d. It can work with C125, C127, C155, C157.




UEi 16646 Thermal Paper for Select Infrared Thermal Printers 16646
Place this thermal paper into your compatible infrared thermal printer and begin recording data.




Ask a question about UEi C165+NOILKIT Residential/Commercial Combustion Analyzer Kit with NOx sensor and smoke pump test kit, 32 to 1112°F, 2000 ppm

Customer Reviews for the UEi C165+NOILKIT

UEi C165+NOILKIT Offers

Features

  • Large 6-line backlit display
  • LINK to wireless probes
  • Wireless flow and return probes
  • NOx filtered and H2 compensated CO sensor (10,000 ppm range)
  • Over-range protection pump
  • NOx filtered CO sensor
  • Room CO test
  • Differential pressure
  • Heat exchanger test
  • Four types of sensor protection
  • Low flow detection to protect reading accuracy
  • High altitude compensation
  • Temperature differential with K-type probe inputs
  • Protective water trap
  • Wireless connection to a free printer App (iOS® and Android™ compatible)
  • Eight pre-programmed fuels
  • Protective rubber boot with magnet
  • DMM-style rotary dial

Functions

  • Measures: Flue gas smoke, NO, CO (10,000 ppm H2 compensated), CO2, differential pressure, flue and inlet temperature
  • Calculates: Differential temperature, efficiency (net, gross), excess air

Applications

  • Residential and commercial combustion analysis
  • Installing and maintaining gas/oil-fired applicances

UEi C165+NOILKIT Specifications

Temperature Measurement
Flue Temperature Range: 32 to 1112°F (0 to 600°C)
Resolution: 0.1°F (0.1°C)
Accuracy: ±(0.3% rdg +3.6°F [2°C])
Inlet Temperature (Internal Sensor) Range: 32 to 122°F (0 to 50°C)
Resolution: 0.1°F (0.1°C)
Accuracy: +1.8°C +0.3% rdg
Inlet Temperature (External Sensor) Range: 32 to 1112°F (0 to 600°C)
Resolution: 0.1° (0.1°C)
Accuracy: +3.6°F +0.3% rdg
Flue Gas Measurement
Oxygen Range: 0 to 21%
Resolution: 0.1%
Accuracy: +0.3% volume
Carbon Monoxide Range: 0 to 2000 ppm; 2000 to 9999 ppm; above 9999 pm
Resolution: 1 ppm
Accuracy: ±3 ppm or ±5% rdg; ±10% of rdg; unspecified
Carbon Dioxide Range: 0 to 20%
Resolution: 0.1%
Accuracy: 0.3% rdg
Efficiency (Net or Gross) Range: 0 to 99.9%
Resolution: 0.1%
Accuracy: +1% rdg
Efficiency High (C) Range: 0 to 119.9%
Resolution: 0.1%
Accuracy: +1% rdg
Excess Air Range: 0 to 250%
Resolution: 0.1%
Accuracy: +0.2% rdg
CO/CO2 Ratio Range: 0 to 0.9999%
Resolution: 0.0001
Accuracy: +5% rdg
Nitric Oxide Sensor Range: 0 to 100 ppm; overrange to 1500 ppm
Resolution: 1 ppm
Accuracy: + 2 ppm <30 ppm; +5 ppm <100 ppm; +5% reading >100 ppm
Pressure (Differential)
Range ±80 mbar
Resolution 0.1 mbar
Accuracy ±0.5% FSD
General Specifications
Pre-Programmed Fuels Natural gas, propane, butane, LPG, light oils (28/35 seconds), wood pellets, town gas, coke
Environmental Conditions Operating temperature: 32 to 112°F (0 to 45°C)
Storage temperature: 0 to 120°F (-18 to 50°C)
Humidity: 10 to 90% RH
Certification CE Conformity, RoHS, REACH Compliant, AHRI 1260 standard, FCC
Dimensions 7.87 x 1.77 x 3.5" (200 x 44.9 x 88.9 mm)
Weight 1.38 lbs (0.63 kg)
Click here for complete specifications on the UEi C165+NOILKIT

What's included with the UEi C165+NOILKIT

  • Combustion Analyzer
  • Flue Gas Probe
  • 2 x Wireless Pipe Clamp Probes
  • 2 x K-Type Thermocouples
  • Smoke Pump Test Kit
  • IR Thermal Printer
  • Spare Printer Paper Roll
  • Particle Filter
  • Tubing with Connector
  • Carrying Case
  • 3 x AA Rechargeable Batteries
  • USB Charging Cable
  • Quick Start Guide
  • 10-Year Warranty

Click on a category to view a selection of compatible accessories with the UEi C165+NOILKIT Residential/Commercial Combustion Analyzer Kit with NOx sensor and smoke pump test kit, 32 to 1112°F, 2000 ppm.

UEi AC509 Hard Carrying Case AC509
UEi AC509 hard sided blow-molded case for the eagle & eagle x combustion analyzers protective compartment for analyzer, printer and accessories flue probe storage separated from analyzer to protect the instrument size 19"w x 14"h x 3-1/2"d. It can work with C125, C127, C155, C157.




UEi 16646 Thermal Paper for Select Infrared Thermal Printers 16646
Place this thermal paper into your compatible infrared thermal printer and begin recording data.




Ask a question about UEi C165+NOILKIT Residential/Commercial Combustion Analyzer Kit with NOx sensor and smoke pump test kit, 32 to 1112°F, 2000 ppm

Customer Reviews for the UEi C165+NOILKIT

More UEi Products