Engineered for advanced copper and fiber certification, this complete bundle includes the LanTEK IV-S 3000 MHz certifier with Permanent Link and Channel Adapters, capable of Cat8.2 testing and Cat6A certification in just 7 seconds. Additionally, it also features the FiberTEK IV MM LED and SM laser kit, FiberMASTER Quad OTDR, a video inspection probe, launch cables, and Sapphire Care Plan.
Engineered for advanced copper and fiber certification, this complete bundle includes the LanTEK IV-S 3000 MHz certifier with Permanent Link and Channel Adapters, capable of Cat8.2 testing and Cat6A certification in just 7 seconds. Additionally, it also features the FiberTEK IV MM LED and SM laser kit, FiberMASTER Quad OTDR, a video inspection probe, launch cables, and Sapphire Care Plan.
LanTEK IV-S
The LanTEK IV-S copper and fiber data cable certifier is the future of cable certification and testing. Saving you time it will test and save a Cat6A link in 7 seconds and certifies links up to Cat8.1 and Cat8.2, including TCL and Resistance Unbalance measurements.
FiberTEK IV
FiberTEK IV adapters are used with LanTEK IV-S for fast and simple certification of high bandwidth single-mode and multimode fiber optic cabling including support for encircled flux testing.
FiberMASTER OTDR
The OTDRs feature both high dynamic range and small dead zones providing the precision required for installation and troubleshooting alike.
Sapphire Care Plan
The Sapphire Care Plan is designed to help minimise down time, reduce the cost of ownership and protect against unforeseen repair bills.
LanTEK IV-S | |
Battery | Lithium-ion, 7.4 V DC, 6.6Ah (48.84 Wh typical) Input: 12 V/2 A DC Typical operating time: 8 hours (new battery running a Cat6 test every 20 seconds, full backlight) Charge time: <4 hours quick charge with battery removed from handset, <8 hours inside handset Input power: Handset DC 12 to 15 V, 2A |
Line/Mains Power Adapters | Input: AC 110 to 240 V, 50/60 Hz Output: 12 - 2500mA, 5.5mm x 2.5mm x 12mm, center positive |
Display | IPS, 480x854 pixels, 5” diagonal, capacitive touch LCD, scratch-resistant acrylic screen |
Connectivity | Test module port: 120 pin ultra-low crosstalk module interface USC C (USB 2.0), USB A (USB 2.0), 3.5 mm talk set jack, power/charging jack, integrated Wi-Fi (2.4/5 GHz bands) 802.11a/b/g/n (model available with Wi-Fi disabled) |
Input Methods | Capacitive touchscreen, USB keyboard, USB mouse |
Frequency Range | 1 to 3000 MHz |
CPU Module (Main Handset) | CPU: 1.0 GHz, 32-bit Cortex™ A9 processor, Dual-core ARM7 System memory: 1024 MB RAM System storage: 16 GB eMMC Flash |
CPU Module (Remote Handset) | CPU: 900 MHz, 32-bit Cortex™ A7 processor, Single-core ARM7 System memory: 128 MB RAM System storage: 8 GB eMMC Flash |
Test Storage | Non-volatile flash, capacity for 5000 tests with graphs |
Data Transfer | Network transfer to cloud via Wi-Fi Export to USB flash drive (supports up to 256 GB, FAT32 format required) |
Measurements | Twisted pair copper cable: Wire map, DC loop resistance length, capacitance, NEXT, insertion loss, ACR-N, return loss, average impedance, propagation delay, delay skew, power sum NEXT, power sum ACR-N, ACR-F, power sum ACR-F, TCL (Transverse Conversion Loss), ELTCTL (EqualLevel Transverse Conversion Transfer Loss, DC loop resistance, DC resistance unbalance (pair-to-pair/intra-pair),Time Domain NEXT and Time Domain Return Loss fault finding identifies the location of NEXT and RL events Fibre optic cabling (optional FiberTEK IV test modules): Dual-wavelength insertion loss (each fiber), length Supported wavelengths: Multimode 850/1300nm, Single-mode 1310/1550 nm Fault location with integrated laser visual fault locator |
Supported Cable Types | ANSI/TIA Category 3, 4, 5, 5E, 6, 6A and 8: 100Ω ANSI/SCTE Series 59, 6 and 11: 75 Ω, RG-58: 50 Ω ISO/IEC Class C, D, E, EA, F, FA and 8: 100Ω OM1-OM5 multimode and OS1-OS2 single-mode fibre optic cable OM1–OM5 multimode and OS1–OS2 single-mode fiber |
Test Interface | 120-pin ultra-low crosstalk connector |
Supported Connectors | TIA Cat 6/6A, ISO Class E/EA RJ-45 permanent link adapters TIA Cat 8.1, ISO Class I/II RJ-45 permanent link adapters TIA Cat 6/6A, ISO Class E/EA RJ-45 channel adapters TIA Cat 8.1, ISO Class I/II RJ-45 channel adapters TERA/GG45/EC7 (MMCPRO3000) Cat 8.2 universal adapters for channel and permanent link testing M12-X, 4-pair Cat 6A universal adapters for channel and permanent link testing M12-D, 2-pair Cat 5e universal adapters for channel and permanent link testing Coaxial adapters for 50/75-ohm cable with female BNC connector. Tests to 500 MHz with LanTEK IV-S 500, or 3000 MHz with LanTEK IV-S 3000 depending on selected standard. BNC to F-type adapter included. SC/FC/ST fibre optic connectors included with FiberTEK IV kits. LC adapter kit optional (sold separately) |
Test Times | Copper: 7 seconds to 1000 MHz 23 seconds to 3000 MHz Including required/optional tests Fiber: 14 seconds dual-wavelength, one direction 28 seconds, dual-wavelength, bi-directional |
Wiremap Distance to Fault Display Resolution | 3.9" (10 cm) |
Length Measurement | Copper: 0 to 1960' (0 to 600 m) Fiber: 0 to 32,808' (0 to 10 km) Display resolution: 1' (0.1 m) |
DC Resistance | Range: 0.02 to 200 ohms Display resolution: 0.1 ohms |
Propagation Delay | Measurement range: 1 ns to 1 s Display resolution: 1 ns |
RF Measurement | Accuracy: ISO/IEC 61935-1 Ed 5, ANSI/TIA-1152-A Display resolution: 0.1 dB |
Operating Temperature | 32 to 113°F (0 to 45°C), non-condensing |
Storage Temperature | -4 to 158°F (-20 to 70°C), non-condensing |
Shock/Vibration | MIL-PRF-28800F, Class 3 (design-compliant) |
User Interface Languages | Chinese, English, French, German, Italian, Portuguese, Russian, Spanish |
Accuracy Certification | ETL Verified: ANSI/TIA-1152-A Level 2G, IEC 61935-1 Level VI |
PC Software | TREND AnyWARE Cloud Web client – requires HTML 5 compatible browser TREND AnyWARE Desktop software Requirements: Microsoft Windows 10 or higher, 2 GB RAM, 500 MB hard disk + 1 GB for every 1,500 Category 6 tests |
Conformance | IEC 61010-1:2010 Ed 3 - Safety requirements for electrical equipment for measurement, control and laboratory use. EN61326-1:2013 – Electrical equipment for measurement, control and laboratory use. EMC requirements. EN55011:2009 + A2:2010 – Industrial, scientific and medical equipment. Radio frequency disturbance characteristics. ENGl000-4-2:2009 - Electrostatic Discharge Immunity Test EN61000-4-3:2006+A2:2010 - Radiated, radio-frequency, electromagnetic field immunity test EN61000-4-4:2004+Al:2010 - Electrical Fast Transient / Burst Immunity Test ENGl000-4-5:2006 - Surge Immunity Test EN61000-4-6:2009 - Immunity to conducted disturbances, induced by radiofrequency fields EN61000-4-11:2004 - Voltage dips, short interruptions and voltage variations immunity tests Instrument: CE, C-Tick, FCC Part 15, Class A Battery: DOT 49 CFR 173.185, UN Part IV – section 38.3 |
Warranty | Instrument: one (1) year from date of delivery Accessories: one (1) year from date of delivery Batteries: six (6) months from date of delivery |
Dimensions | 10 x 5 x 2.1" (25.4 x 12.7 x 5.3 cm) |
Weight (with battery) |
Display: 2.35 lbs (1.1 kg) Remote: 2.30 lbs (1.0 kg) |
FiberTEK IV | |
Optical Characteristics | Typical output power: -20 dBm at 850 nm -15 dBm at 1300 nm -7 dBm at 1310/1550 nm Receiver sensitivity: 60 dBm (loss measurement) -45 dBm (loss and length measurement) Encircled flux test cord insertion loss: <3.0 dB each |
FiberMASTER OTDR | |
Safety (FDA/CDRH and IEC-825-1) |
Class 1 |
Number of Data Points | Up to 128,000 |
Display Range | Up to 160 miles (256 km) |
Minimum Sampling Resolution | 2.36" (6 cm) |
Distance Accuracy | ±[29.5" (0.75 m) + 0.005% × Distance + Sampling Resolution] |
Attenuation | Resolution: 0.001 dB Linearity: ±0.03 dB/dB |
850/1300 ±20 nm | RMS dynamic range: 29/30 dB Pulse widths: 5 ns to 1 μs Event dead zone: 1 m Attenuation dead zone: 5 m |
1310/1550 ±20 nm | RMS dynamic range: 37/38 dB Pulse widths: 5 ns to 20 μs Event dead zone: 1 m Attenuation dead zone: 5 m |
1625 ±20 nm | RMS dynamic range: 36 dB Pulse widths: 5 ns to 20 μs Event dead zone: 1 m Attenuation dead zone: 5 m |
Connector Styles | SC/UPC (SC/APC on PON model), ST/FC optional |
Light Source | Wavelengths (QUAD): 850, 1300, 1310, 1550 nm Wavelengths (PON): 1310, 1550, 1625 nm Output power: 0 dBm Modulation: CW, 270 Hz, 1000 Hz, 2000 Hz |
VFL (Visual Fault Locator) | Wavelength: 650 nm ±5 nm Connector: 2.5 mm universal Output power: 1 mW maximum |
Power Meter | Connector styles: LC, SC, FC, ST, 2.5 mm universal, 1.25 mm universal Dynamic range: +5 dBm to -77 dBm Calibrated wavelengths: 850, 1300, 1310, 1490, 1550, 1625 nm Power meter uncertainty: ±0.18 dB under reference conditions ±0.25 dB from 0 to -65 dBm ±0.35 dB from 0 to +5 dBm and -65 to -77 dBm Units of measurement: dBm, dB Resolution: 0.01 dB |
Display | 3.5" (8.9 cm) color resistive touchscreen Resolution: 240 × 320 |
Communication interfaces | Micro USB, Bluetooth |
Storage | Up to 40,000 records depending on file size |
Battery | 30 Wh, rechargeable lithium-polymer, up to 10 hours of operation |
Power supply | Input: 100 to 250 V AC, 50/60 Hz Output: USB 5 V DC, 2 A |
Safety | OTDR: Class 1 (FDA/IEC-825-1) VFL: Class 2 |
Dimensions | 6.69 x 4.17 x 1.97" (170 x 106 x 50 mm) |
Weight | 1.5 lbs (700 g) |
Click on a category to view a selection of compatible accessories with the TREND Networks LT4-3000FOS-3Y Cable Certifier Bundle includes LanTEK IV-S 3000 MHz + FiberTEK IV + FiberMASTER OTDR + Accessories + Sapphire 3 Years.
LanTEK IV-S | |
Battery | Lithium-ion, 7.4 V DC, 6.6Ah (48.84 Wh typical) Input: 12 V/2 A DC Typical operating time: 8 hours (new battery running a Cat6 test every 20 seconds, full backlight) Charge time: <4 hours quick charge with battery removed from handset, <8 hours inside handset Input power: Handset DC 12 to 15 V, 2A |
Line/Mains Power Adapters | Input: AC 110 to 240 V, 50/60 Hz Output: 12 - 2500mA, 5.5mm x 2.5mm x 12mm, center positive |
Display | IPS, 480x854 pixels, 5” diagonal, capacitive touch LCD, scratch-resistant acrylic screen |
Connectivity | Test module port: 120 pin ultra-low crosstalk module interface USC C (USB 2.0), USB A (USB 2.0), 3.5 mm talk set jack, power/charging jack, integrated Wi-Fi (2.4/5 GHz bands) 802.11a/b/g/n (model available with Wi-Fi disabled) |
Input Methods | Capacitive touchscreen, USB keyboard, USB mouse |
Frequency Range | 1 to 3000 MHz |
CPU Module (Main Handset) | CPU: 1.0 GHz, 32-bit Cortex™ A9 processor, Dual-core ARM7 System memory: 1024 MB RAM System storage: 16 GB eMMC Flash |
CPU Module (Remote Handset) | CPU: 900 MHz, 32-bit Cortex™ A7 processor, Single-core ARM7 System memory: 128 MB RAM System storage: 8 GB eMMC Flash |
Test Storage | Non-volatile flash, capacity for 5000 tests with graphs |
Data Transfer | Network transfer to cloud via Wi-Fi Export to USB flash drive (supports up to 256 GB, FAT32 format required) |
Measurements | Twisted pair copper cable: Wire map, DC loop resistance length, capacitance, NEXT, insertion loss, ACR-N, return loss, average impedance, propagation delay, delay skew, power sum NEXT, power sum ACR-N, ACR-F, power sum ACR-F, TCL (Transverse Conversion Loss), ELTCTL (EqualLevel Transverse Conversion Transfer Loss, DC loop resistance, DC resistance unbalance (pair-to-pair/intra-pair),Time Domain NEXT and Time Domain Return Loss fault finding identifies the location of NEXT and RL events Fibre optic cabling (optional FiberTEK IV test modules): Dual-wavelength insertion loss (each fiber), length Supported wavelengths: Multimode 850/1300nm, Single-mode 1310/1550 nm Fault location with integrated laser visual fault locator |
Supported Cable Types | ANSI/TIA Category 3, 4, 5, 5E, 6, 6A and 8: 100Ω ANSI/SCTE Series 59, 6 and 11: 75 Ω, RG-58: 50 Ω ISO/IEC Class C, D, E, EA, F, FA and 8: 100Ω OM1-OM5 multimode and OS1-OS2 single-mode fibre optic cable OM1–OM5 multimode and OS1–OS2 single-mode fiber |
Test Interface | 120-pin ultra-low crosstalk connector |
Supported Connectors | TIA Cat 6/6A, ISO Class E/EA RJ-45 permanent link adapters TIA Cat 8.1, ISO Class I/II RJ-45 permanent link adapters TIA Cat 6/6A, ISO Class E/EA RJ-45 channel adapters TIA Cat 8.1, ISO Class I/II RJ-45 channel adapters TERA/GG45/EC7 (MMCPRO3000) Cat 8.2 universal adapters for channel and permanent link testing M12-X, 4-pair Cat 6A universal adapters for channel and permanent link testing M12-D, 2-pair Cat 5e universal adapters for channel and permanent link testing Coaxial adapters for 50/75-ohm cable with female BNC connector. Tests to 500 MHz with LanTEK IV-S 500, or 3000 MHz with LanTEK IV-S 3000 depending on selected standard. BNC to F-type adapter included. SC/FC/ST fibre optic connectors included with FiberTEK IV kits. LC adapter kit optional (sold separately) |
Test Times | Copper: 7 seconds to 1000 MHz 23 seconds to 3000 MHz Including required/optional tests Fiber: 14 seconds dual-wavelength, one direction 28 seconds, dual-wavelength, bi-directional |
Wiremap Distance to Fault Display Resolution | 3.9" (10 cm) |
Length Measurement | Copper: 0 to 1960' (0 to 600 m) Fiber: 0 to 32,808' (0 to 10 km) Display resolution: 1' (0.1 m) |
DC Resistance | Range: 0.02 to 200 ohms Display resolution: 0.1 ohms |
Propagation Delay | Measurement range: 1 ns to 1 s Display resolution: 1 ns |
RF Measurement | Accuracy: ISO/IEC 61935-1 Ed 5, ANSI/TIA-1152-A Display resolution: 0.1 dB |
Operating Temperature | 32 to 113°F (0 to 45°C), non-condensing |
Storage Temperature | -4 to 158°F (-20 to 70°C), non-condensing |
Shock/Vibration | MIL-PRF-28800F, Class 3 (design-compliant) |
User Interface Languages | Chinese, English, French, German, Italian, Portuguese, Russian, Spanish |
Accuracy Certification | ETL Verified: ANSI/TIA-1152-A Level 2G, IEC 61935-1 Level VI |
PC Software | TREND AnyWARE Cloud Web client – requires HTML 5 compatible browser TREND AnyWARE Desktop software Requirements: Microsoft Windows 10 or higher, 2 GB RAM, 500 MB hard disk + 1 GB for every 1,500 Category 6 tests |
Conformance | IEC 61010-1:2010 Ed 3 - Safety requirements for electrical equipment for measurement, control and laboratory use. EN61326-1:2013 – Electrical equipment for measurement, control and laboratory use. EMC requirements. EN55011:2009 + A2:2010 – Industrial, scientific and medical equipment. Radio frequency disturbance characteristics. ENGl000-4-2:2009 - Electrostatic Discharge Immunity Test EN61000-4-3:2006+A2:2010 - Radiated, radio-frequency, electromagnetic field immunity test EN61000-4-4:2004+Al:2010 - Electrical Fast Transient / Burst Immunity Test ENGl000-4-5:2006 - Surge Immunity Test EN61000-4-6:2009 - Immunity to conducted disturbances, induced by radiofrequency fields EN61000-4-11:2004 - Voltage dips, short interruptions and voltage variations immunity tests Instrument: CE, C-Tick, FCC Part 15, Class A Battery: DOT 49 CFR 173.185, UN Part IV – section 38.3 |
Warranty | Instrument: one (1) year from date of delivery Accessories: one (1) year from date of delivery Batteries: six (6) months from date of delivery |
Dimensions | 10 x 5 x 2.1" (25.4 x 12.7 x 5.3 cm) |
Weight (with battery) |
Display: 2.35 lbs (1.1 kg) Remote: 2.30 lbs (1.0 kg) |
FiberTEK IV | |
Optical Characteristics | Typical output power: -20 dBm at 850 nm -15 dBm at 1300 nm -7 dBm at 1310/1550 nm Receiver sensitivity: 60 dBm (loss measurement) -45 dBm (loss and length measurement) Encircled flux test cord insertion loss: <3.0 dB each |
FiberMASTER OTDR | |
Safety (FDA/CDRH and IEC-825-1) |
Class 1 |
Number of Data Points | Up to 128,000 |
Display Range | Up to 160 miles (256 km) |
Minimum Sampling Resolution | 2.36" (6 cm) |
Distance Accuracy | ±[29.5" (0.75 m) + 0.005% × Distance + Sampling Resolution] |
Attenuation | Resolution: 0.001 dB Linearity: ±0.03 dB/dB |
850/1300 ±20 nm | RMS dynamic range: 29/30 dB Pulse widths: 5 ns to 1 μs Event dead zone: 1 m Attenuation dead zone: 5 m |
1310/1550 ±20 nm | RMS dynamic range: 37/38 dB Pulse widths: 5 ns to 20 μs Event dead zone: 1 m Attenuation dead zone: 5 m |
1625 ±20 nm | RMS dynamic range: 36 dB Pulse widths: 5 ns to 20 μs Event dead zone: 1 m Attenuation dead zone: 5 m |
Connector Styles | SC/UPC (SC/APC on PON model), ST/FC optional |
Light Source | Wavelengths (QUAD): 850, 1300, 1310, 1550 nm Wavelengths (PON): 1310, 1550, 1625 nm Output power: 0 dBm Modulation: CW, 270 Hz, 1000 Hz, 2000 Hz |
VFL (Visual Fault Locator) | Wavelength: 650 nm ±5 nm Connector: 2.5 mm universal Output power: 1 mW maximum |
Power Meter | Connector styles: LC, SC, FC, ST, 2.5 mm universal, 1.25 mm universal Dynamic range: +5 dBm to -77 dBm Calibrated wavelengths: 850, 1300, 1310, 1490, 1550, 1625 nm Power meter uncertainty: ±0.18 dB under reference conditions ±0.25 dB from 0 to -65 dBm ±0.35 dB from 0 to +5 dBm and -65 to -77 dBm Units of measurement: dBm, dB Resolution: 0.01 dB |
Display | 3.5" (8.9 cm) color resistive touchscreen Resolution: 240 × 320 |
Communication interfaces | Micro USB, Bluetooth |
Storage | Up to 40,000 records depending on file size |
Battery | 30 Wh, rechargeable lithium-polymer, up to 10 hours of operation |
Power supply | Input: 100 to 250 V AC, 50/60 Hz Output: USB 5 V DC, 2 A |
Safety | OTDR: Class 1 (FDA/IEC-825-1) VFL: Class 2 |
Dimensions | 6.69 x 4.17 x 1.97" (170 x 106 x 50 mm) |
Weight | 1.5 lbs (700 g) |
Click on a category to view a selection of compatible accessories with the TREND Networks LT4-3000FOS-3Y Cable Certifier Bundle includes LanTEK IV-S 3000 MHz + FiberTEK IV + FiberMASTER OTDR + Accessories + Sapphire 3 Years.