Compatible with any oscilloscope having a high-impedance BNC input, this AC/DC probe has high bandwidth, accurate waveform capture, measurement accuracy of up to 1%, and low circuit insertion loss. Ideal for design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
Compatible with any oscilloscope having a high-impedance BNC input, this AC/DC probe has high bandwidth, accurate waveform capture, measurement accuracy of up to 1%, and low circuit insertion loss. Ideal for design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
Powered by an external universal power supply and a set of universal plug adaptors.
Features
Applications
| Bandwidth (-3 dB) | DC to 100 MHz |
| Continuous Maximum Input | 30 A RMS |
| Maximum Peak Input (≤10 µs) | 50 A peak |
| Ranges | 5 to 30 A |
| Overload | 30 to ≥50 A |
| Current Transfer Ratio | 5 A: 1 V/A 30 A: 0.1 V/A |
| Oscilloscope Input Scaling | 5 A: x 1 30 A: x 10 |
| Minimum Measurable Current | 5 A: 1 mA 30 A: 10 mA |
| Amplitude Accuracy (DC, 45 to 66 Hz) | 5 A: ±1%, ±1 mA 30 A: ±1%, ±10 mA |
| Maximum Measurement Conductor Diameter | 0.2" (5 mm) |
| Power Supply | DC 12 V/1 A (supplied) |
| Temperature and Humidity | Operating: 0 to 104°F (0 to 40°C), ≤80% Storage: 14 to 122°F (-10 to 50°C), ≤80% |
| Dimensions | Probe head: 6.93 x 1.56 x 0.71" (176 x 39.5 x 18 mm) Probe head to control box cable length: 3.28' (1 m) |
| Weight | 0.52 lbs (235 g) |
| Bandwidth (-3 dB) | DC to 100 MHz |
| Continuous Maximum Input | 30 A RMS |
| Maximum Peak Input (≤10 µs) | 50 A peak |
| Ranges | 5 to 30 A |
| Overload | 30 to ≥50 A |
| Current Transfer Ratio | 5 A: 1 V/A 30 A: 0.1 V/A |
| Oscilloscope Input Scaling | 5 A: x 1 30 A: x 10 |
| Minimum Measurable Current | 5 A: 1 mA 30 A: 10 mA |
| Amplitude Accuracy (DC, 45 to 66 Hz) | 5 A: ±1%, ±1 mA 30 A: ±1%, ±10 mA |
| Maximum Measurement Conductor Diameter | 0.2" (5 mm) |
| Power Supply | DC 12 V/1 A (supplied) |
| Temperature and Humidity | Operating: 0 to 104°F (0 to 40°C), ≤80% Storage: 14 to 122°F (-10 to 50°C), ≤80% |
| Dimensions | Probe head: 6.93 x 1.56 x 0.71" (176 x 39.5 x 18 mm) Probe head to control box cable length: 3.28' (1 m) |
| Weight | 0.52 lbs (235 g) |