Teledyne LeCroy MS-500 500 MHz Mixed Signal Oscilloscope Option

Model: MS-500

Teledyne LeCroy MS-500 500 MHz Mixed Signal Oscilloscope Option

Model: MS-500

Designed to capture long records of the fastest digital signals the MS-500 has a maximum input frequency of 500 MHz. The long memory of 50 Mpts/Ch means that these fast signals can be captured for up to 25 ms at up to 2 GS/s sampling rate.

Designed to capture long records of the fastest digital signals the MS-500 has a maximum input frequency of 500 MHz. The long memory of 50 Mpts/Ch means that these fast signals can be captured for up to 25 ms at up to 2 GS/s sampling rate.

Sale Price $10161.62 CAD
Regular Price $10369.00 CAD
Availability 2 to 3 Weeks
Quantity

Teledyne LeCroy MS-500 Offers

The MS-500 is ideally suited for embedded controller testing where there is a proliferation of analog signals coincident with digital signals.

Features

  • Trigger and decode serial data signals such as I2C, SPI, UART, RS-232, and LIN
  • Use cursors to read hexadecimal bus values or make manual timing measurements
  • Automatic measurement parameters like period, frequency and duty cycle work on digital lines just as they would on oscilloscope channels
  • Analog bandwidths from 200 MHz to 2 GHz with sampling rates up to 10 GS/s
  • Up to 50 Mpts/Ch digital memory provides very long capture times of all your digital signals, with sampling rates up to 2 GS/s
  • Long oscilloscope memory enables capturing long records of analog signals while maintaining high sample rate for fast edges
  • Complete analog/digital cross triggering
  • Sampling rate of 2 GS/s on digital lines

Teledyne LeCroy MS-500 Specifications

Maximum Input Frequency 500 MHz
Sample Rate 2 GS/s
Acquisition Memory (Per Channel) 50 Mpts/Ch (10 Mpts/Ch max. memory when used with WaveSurfer Xs and WaveSurfer MXs)
Number of Digital Channels 18
Threshold Groupings D0-D8, D9-D17
Threshold Levels TTL, eCL, CMOS (2.5 V, 3.3 V, 5 V), PeCL, LVDS or User Defined
Trigger Types edge, Width, Pattern, Glitch, Interval, Dropout
Serial Data Triggers (Optional) I2C, SPI, UART, RS-232, LIN
Trigger Sources C1-C4, D0-D17, eXT
Dimensions 4.25 x 8.375 x 1.5" (10.8 x 21.3 x 3.8 cm)
Net Weight 1.7 lbs (0.775 kg)
Lead Set Length 16" (40.65 cm)
Click here for complete specifications on the Teledyne LeCroy MS-500

What's included with the Teledyne LeCroy MS-500

  • Teledyne LeCroy MS-500 500 MHz Mixed Signal Oscilloscope Option

Click on a category to view a selection of compatible accessories with the Teledyne LeCroy MS-500 500 MHz Mixed Signal Oscilloscope Option.

Teledyne LeCroy MSO-DLS-18 18 Channel Lead Set Replacement (D0-D17) MSO-DLS-18
16" 18 Channel Digital Lead Set.




Ask a question about Teledyne LeCroy MS-500 500 MHz Mixed Signal Oscilloscope Option

Customer Reviews for the Teledyne LeCroy MS-500

Teledyne LeCroy MS-500 Offers

The MS-500 is ideally suited for embedded controller testing where there is a proliferation of analog signals coincident with digital signals.

Features

  • Trigger and decode serial data signals such as I2C, SPI, UART, RS-232, and LIN
  • Use cursors to read hexadecimal bus values or make manual timing measurements
  • Automatic measurement parameters like period, frequency and duty cycle work on digital lines just as they would on oscilloscope channels
  • Analog bandwidths from 200 MHz to 2 GHz with sampling rates up to 10 GS/s
  • Up to 50 Mpts/Ch digital memory provides very long capture times of all your digital signals, with sampling rates up to 2 GS/s
  • Long oscilloscope memory enables capturing long records of analog signals while maintaining high sample rate for fast edges
  • Complete analog/digital cross triggering
  • Sampling rate of 2 GS/s on digital lines

Teledyne LeCroy MS-500 Specifications

Maximum Input Frequency 500 MHz
Sample Rate 2 GS/s
Acquisition Memory (Per Channel) 50 Mpts/Ch (10 Mpts/Ch max. memory when used with WaveSurfer Xs and WaveSurfer MXs)
Number of Digital Channels 18
Threshold Groupings D0-D8, D9-D17
Threshold Levels TTL, eCL, CMOS (2.5 V, 3.3 V, 5 V), PeCL, LVDS or User Defined
Trigger Types edge, Width, Pattern, Glitch, Interval, Dropout
Serial Data Triggers (Optional) I2C, SPI, UART, RS-232, LIN
Trigger Sources C1-C4, D0-D17, eXT
Dimensions 4.25 x 8.375 x 1.5" (10.8 x 21.3 x 3.8 cm)
Net Weight 1.7 lbs (0.775 kg)
Lead Set Length 16" (40.65 cm)
Click here for complete specifications on the Teledyne LeCroy MS-500

What's included with the Teledyne LeCroy MS-500

  • Teledyne LeCroy MS-500 500 MHz Mixed Signal Oscilloscope Option

Click on a category to view a selection of compatible accessories with the Teledyne LeCroy MS-500 500 MHz Mixed Signal Oscilloscope Option.

Teledyne LeCroy MSO-DLS-18 18 Channel Lead Set Replacement (D0-D17) MSO-DLS-18
16" 18 Channel Digital Lead Set.




Ask a question about Teledyne LeCroy MS-500 500 MHz Mixed Signal Oscilloscope Option

Customer Reviews for the Teledyne LeCroy MS-500

More Teledyne LeCroy Products