The Si-RM450 is a digital manifold gauge set used by HVAC/R technicians to measure, diagnose, and service refrigerant systems (air conditioners, heat pumps, refrigeration units). The smart digital assistant Sauermann Pilot mobile application guides the operator to help them commission and service all types of refrigerant-based installations. Includes Si-RM450 4-way manifold, two Si-RT7 wireless temperature clamps, one Si-RV4 wireless vacuum probe, hard plastic case, batteries and adjusting certificate.
The Si-RM450 is a digital manifold gauge set used by HVAC/R technicians to measure, diagnose, and service refrigerant systems (air conditioners, heat pumps, refrigeration units). The smart digital assistant Sauermann Pilot mobile application guides the operator to help them commission and service all types of refrigerant-based installations. Includes Si-RM450 4-way manifold, two Si-RT7 wireless temperature clamps, one Si-RV4 wireless vacuum probe, hard plastic case, batteries and adjusting certificate.
The Si-RM450 replaces traditional analog gauges with digital sensors and software that deliver faster, more accurate readings and more advanced diagnostics. It automatically calculates key system values such as high- and low-side pressure, temperature when used with clamp probes, superheat, subcooling, and saturation temperature based on the selected refrigerant, making it easy to view overall system performance at a glance. The unit also connects wirelessly to temperature clamps and a refrigerant scale, while the Sauermann Pilot mobile app supports data logging, live monitoring, and job report creation. In addition, it is compatible with a wide range of A1, A2L, and A3 refrigerants and automatically applies the correct pressure/temperature relationships for the refrigerant in use.
Features
Applications
| Pressure Valves | 4 valves |
| Measuring Range | -1 to 60 bar (-14 to 870 psi) |
| Pressure Accuracy | ±0.50% of full scale |
| Available Units | bar, psi, kPa, MPa |
| Resolution | 0.01 bar/0.1 psi/1 kPa/01 MPa |
| Overload | 65 bar (943 psi) |
| Burst Pressure | 150 bar (2175 psi) |
| Max Hose Pressure | 55 bar (800 psi) |
| Power Supply | 4 x LR6 or AA 1.5 V batteries. Alternative power supply: USB-C |
| Battery Life | 300 hours |
| Memory | Up to 600,000 points and 9 days of recording |
| Display | Graphic screen 240 x 128 pixel |
| Pressure Connectors | 3 x 1/4 MFL male + 3/8 MFL male |
| Temperature Connectors | 2 x wired jack (NTC) |
| Wireless Frequency Range | From 2402 MHz to 2480 MHz with a transmission power of 8 dBm |
| Wireless Range | Up to 328' (100 m) between manifold and wireless probes |
| Superheat and Subcooling | Smartphone minimum required versions: Android 11.0, iOS 15, BLE 5.0 Port USB-C |
| Refrigerant Database | Automatically calculated by the device |
| Operating Temperature | R11, R113, R114, R115, R1150, R116, R12, R123, R124, R125, R1270, R13, R134a, R13b1, R14, R141b, R142b, R143a, R152a, R161, R170, R218, R22, R227, R23, R236ea, R236fa, R245ca, R245fa, R290, R32, R600, R600a, R601, R601a, R718, R744, R744a, R50, R41, R1233zd(E), R1234yf, R1234zeE, R1234zeZ, R401A, R401B, R401C, R402A, R402B, R403A, R403B, R404A, R405A, R406A, R407A, R407B, R407C, R407D, R407E, R407F, R407H, R408A, R409A, R409B, R410A, R410B, R411A, R411B, R412A, R413A, R414A, R414B, R416A, R417A, R417B, R417C, R418A, R419A, R419B, R420A, R421A, R421B, R422A, R422B, R422C, R422D, R422E, R423A, R424A, R425A, R426A, R427A, R428A, R434A, R437A, R438A, R439A, R440A, R441A, R442A, R443A, R444A, R444B, R445A, R446A, R447A, R448A, R449A, R450A, R452A, R452B, R453A, R454A, R454B, R454C, R455A, R456A, R458A, R466A, R469A, R500, R501, R502, R503, R504, R507A, R508A, R508B, R509A, R511A, R513A |
| Dimensions | -4 to 122°F (-20 to 50°C) |
| Weight | 6-13/32 x 2-1/16 x 6 19/32" (162 x 68 x 168 mm) |
| Pressure Valves | 4 valves |
| Measuring Range | -1 to 60 bar (-14 to 870 psi) |
| Pressure Accuracy | ±0.50% of full scale |
| Available Units | bar, psi, kPa, MPa |
| Resolution | 0.01 bar/0.1 psi/1 kPa/01 MPa |
| Overload | 65 bar (943 psi) |
| Burst Pressure | 150 bar (2175 psi) |
| Max Hose Pressure | 55 bar (800 psi) |
| Power Supply | 4 x LR6 or AA 1.5 V batteries. Alternative power supply: USB-C |
| Battery Life | 300 hours |
| Memory | Up to 600,000 points and 9 days of recording |
| Display | Graphic screen 240 x 128 pixel |
| Pressure Connectors | 3 x 1/4 MFL male + 3/8 MFL male |
| Temperature Connectors | 2 x wired jack (NTC) |
| Wireless Frequency Range | From 2402 MHz to 2480 MHz with a transmission power of 8 dBm |
| Wireless Range | Up to 328' (100 m) between manifold and wireless probes |
| Superheat and Subcooling | Smartphone minimum required versions: Android 11.0, iOS 15, BLE 5.0 Port USB-C |
| Refrigerant Database | Automatically calculated by the device |
| Operating Temperature | R11, R113, R114, R115, R1150, R116, R12, R123, R124, R125, R1270, R13, R134a, R13b1, R14, R141b, R142b, R143a, R152a, R161, R170, R218, R22, R227, R23, R236ea, R236fa, R245ca, R245fa, R290, R32, R600, R600a, R601, R601a, R718, R744, R744a, R50, R41, R1233zd(E), R1234yf, R1234zeE, R1234zeZ, R401A, R401B, R401C, R402A, R402B, R403A, R403B, R404A, R405A, R406A, R407A, R407B, R407C, R407D, R407E, R407F, R407H, R408A, R409A, R409B, R410A, R410B, R411A, R411B, R412A, R413A, R414A, R414B, R416A, R417A, R417B, R417C, R418A, R419A, R419B, R420A, R421A, R421B, R422A, R422B, R422C, R422D, R422E, R423A, R424A, R425A, R426A, R427A, R428A, R434A, R437A, R438A, R439A, R440A, R441A, R442A, R443A, R444A, R444B, R445A, R446A, R447A, R448A, R449A, R450A, R452A, R452B, R453A, R454A, R454B, R454C, R455A, R456A, R458A, R466A, R469A, R500, R501, R502, R503, R504, R507A, R508A, R508B, R509A, R511A, R513A |
| Dimensions | -4 to 122°F (-20 to 50°C) |
| Weight | 6-13/32 x 2-1/16 x 6 19/32" (162 x 68 x 168 mm) |