A powerful handheld gas monitor that measures LEL, O2, H2S, CO, and VOCs, with benzene measurement up to 50/100 ppm. It also features two smart channels for PID, PPM, IR, or super-toxic sensors, and can read combustible gases in both PPM and % volume ranges.
A powerful handheld gas monitor that measures LEL, O2, H2S, CO, and VOCs, with benzene measurement up to 50/100 ppm. It also features two smart channels for PID, PPM, IR, or super-toxic sensors, and can read combustible gases in both PPM and % volume ranges.
The GX-6100 is a powerful hand-held instrument capable of simultaneously monitoring up to 6 gases. In addition to the standard 4 confined space gases which include combustibles, O2, CO, & H2S, the GX-6100 has 2 additional smart channels that accept PID, PPM, IR or super toxic sensors. The updated GX-6100 can measure combustible gases in PPM range and %volume in the same monitor.
Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6100 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. The GX-6100 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Choosing from the library is easy with a personalized favorites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s. A benzene-specific version is available using a pre-filter tube for detecting low levels of benzene. Four PID sensors are available, 10.0 eV, 10.6 eV (low or high range), and 11.7 eV. Any combination of two PID sensors can be installed. GX-6100 PID sensors are also resistant to humidity.
6 Operating Modes
Features
Applications
| PID Sensors | |
| 10.0 Lamp - Benzene Specific | Detection Range: 0 to 50 ppm Reading Increment: 0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 50 ppm) Alarm Set Points: No Alarms Accuracy: ±10% of reading, ±1 digit |
| 10.0 Lamp - 300 VOC’s | Detection Range: 0 to 100 ppm Reading Increment: 0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 100 ppm) Alarm Set Points: A1: 5 ppm A2: 10 ppm A3: 10 ppm Accuracy: ±10% of reading, ±1 digit |
| Electro Chemical R Sensor | |
| Oxygen (O2) | Detection Range: 0 to 40.0% Vol. Reading Increment: 0.1% Vol. Alarm Set Points: A1: 19.5 Vol A2: 18 Vol A3: 23.5 Vol Accuracy: ±0.5% O2 |
| Carbon Monoxide (CO) | Detection Range: 0 to 2,000 ppm Reading Increment: 1 ppm Alarm Set Points: A1: 25 ppm A2: 50 ppm A3: 1,200 ppm TWA: 25 ppm STEL: 200 ppm Accuracy: ±5% of reading or ±5 ppm |
| Hydrogen Sulfide (H2S) | Detection Range: 0 to 200 ppm Reading Increment: 0.5 ppm Alarm Set Points: A1: 5.0 ppm A2: 30.0 ppm A3: 100.0 ppm TWA: 1.0 ppm STEL: 5.0 ppm Accuracy: ±5% of reading or ±2 ppm |
| Smart Sensors NDIR | |
| Carbon Dioxide (CO2) NDIR | Detection Range: 0 to 10,000 ppm 0 to 10.00% Vol. Reading Increment: 20 ppm 0.02% Alarm Set Points (ppm): A1: 5,000 ppm TWA: 5,000 ppm Alarm Set Points (%Vol): A1: 0.50% Vol. A2: 3.00% Vol. A3: 3.00% Vol. STEL: 3.00% Vol. TWA: 0.50% Vol. Accuracy: ±5% of reading or ±2% of full scale |
| Methane NDIR | Detection Range: 0 to 100% LEL 0 to 100% Vol. Reading Increment: 1% LEL 0.5% Vol Alarm Set Points: A1: 10% LEL A2: 50% LEL A3: 50% LEL Accuracy: ±5% of reading or ±2% of full scale |
| Isobutane NDIR | Detection Range: 0 to 100% LEL 0 to 30% Vol. Reading Increment: 1% LEL 0.5% Vol Alarm Set Points: A1: 10% LEL A2: 50% LEL A3: 50% LEL Accuracy: ±5% of reading or ±2% of full scale |
| Smart Sensor (hot-wire semiconductor) MOS | |
| Methane | Detection Range: 0 to 5,000 ppm Reading Increment: 10 ppm Alarm Set Points: N/A Accuracy: N/A |
| Isobutane | Detection Range: 0 to 2,000 ppm Reading Increment: 10 ppm Alarm Set Points: N/A Accuracy: N/A |
| R Sensor (new ceramic type) | |
| Hydrocarbons (CH4, std) | Detection Range: 0 to 100% LEL Reading Increment: 1% LEL Alarm Set Points: A1: 10% LEL A2: 25% LEL A3: 50% LEL Accuracy: ±5% of reading or ±2% LEL |
| TE Sensor (thermal conductivity) | |
| Methane CH4 | Detection Range: 0 to 100 vol% Reading Increment: 1% vol% Alarm Set Points: N/A Accuracy: N/A |
| General Specifications | |
| Alarm Types | Gas alarm: Low and high adjustable Trouble: Low flow, Sensor connection, Low battery, Circuit error, Calibration failure Man Down Alarm Panic Alarm |
| Display | Digital LCD, autobacklight, peak bar display, auto display rotation, and customize order of gases |
| Communication | Bluetooth, IrDA |
| Audible Alarm | 95 dB at 1' (0.30 m) |
| Languages | English, Japanese, French, Spanish, Portuguese, Italian, German, Russian, Korean, Chinese (simplified), Chinese (traditional), Vietnamese, Slovak, Czech, Turkish, Polish |
| Continuous Operation | 28 hours on Lithium-ion battery pack. Complete recharge in 6 hours. 8 hours Alkaline battery pack (3 AA size in each pack) |
| Operating Temp. & Humidity | -4 to 122°F (-20 to 50°C), 0 to 95% RH non condensing |
| Case Material | Dust and water resistant with IP-67 approval (exclude sample hose and probe) |
| Warranty | Three years material (including R sensors) and workmanship 2 years for IR sensors and ESS (except Cl2) One year for TE, Cl2 and PID sensors (Two months for T1.7 eV lamp) |
| Dimensions | 2.6 x 7.9 x 2.2" (6.60 x 20.07 x 5.59 cm) |
| Weight | 17.6 oz (500 g) with lithium battery pack 16 oz (450 g) with alkaline batteries |
| PID Sensors | |
| 10.0 Lamp - Benzene Specific | Detection Range: 0 to 50 ppm Reading Increment: 0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 50 ppm) Alarm Set Points: No Alarms Accuracy: ±10% of reading, ±1 digit |
| 10.0 Lamp - 300 VOC’s | Detection Range: 0 to 100 ppm Reading Increment: 0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 100 ppm) Alarm Set Points: A1: 5 ppm A2: 10 ppm A3: 10 ppm Accuracy: ±10% of reading, ±1 digit |
| Electro Chemical R Sensor | |
| Oxygen (O2) | Detection Range: 0 to 40.0% Vol. Reading Increment: 0.1% Vol. Alarm Set Points: A1: 19.5 Vol A2: 18 Vol A3: 23.5 Vol Accuracy: ±0.5% O2 |
| Carbon Monoxide (CO) | Detection Range: 0 to 2,000 ppm Reading Increment: 1 ppm Alarm Set Points: A1: 25 ppm A2: 50 ppm A3: 1,200 ppm TWA: 25 ppm STEL: 200 ppm Accuracy: ±5% of reading or ±5 ppm |
| Hydrogen Sulfide (H2S) | Detection Range: 0 to 200 ppm Reading Increment: 0.5 ppm Alarm Set Points: A1: 5.0 ppm A2: 30.0 ppm A3: 100.0 ppm TWA: 1.0 ppm STEL: 5.0 ppm Accuracy: ±5% of reading or ±2 ppm |
| Smart Sensors NDIR | |
| Carbon Dioxide (CO2) NDIR | Detection Range: 0 to 10,000 ppm 0 to 10.00% Vol. Reading Increment: 20 ppm 0.02% Alarm Set Points (ppm): A1: 5,000 ppm TWA: 5,000 ppm Alarm Set Points (%Vol): A1: 0.50% Vol. A2: 3.00% Vol. A3: 3.00% Vol. STEL: 3.00% Vol. TWA: 0.50% Vol. Accuracy: ±5% of reading or ±2% of full scale |
| Methane NDIR | Detection Range: 0 to 100% LEL 0 to 100% Vol. Reading Increment: 1% LEL 0.5% Vol Alarm Set Points: A1: 10% LEL A2: 50% LEL A3: 50% LEL Accuracy: ±5% of reading or ±2% of full scale |
| Isobutane NDIR | Detection Range: 0 to 100% LEL 0 to 30% Vol. Reading Increment: 1% LEL 0.5% Vol Alarm Set Points: A1: 10% LEL A2: 50% LEL A3: 50% LEL Accuracy: ±5% of reading or ±2% of full scale |
| Smart Sensor (hot-wire semiconductor) MOS | |
| Methane | Detection Range: 0 to 5,000 ppm Reading Increment: 10 ppm Alarm Set Points: N/A Accuracy: N/A |
| Isobutane | Detection Range: 0 to 2,000 ppm Reading Increment: 10 ppm Alarm Set Points: N/A Accuracy: N/A |
| R Sensor (new ceramic type) | |
| Hydrocarbons (CH4, std) | Detection Range: 0 to 100% LEL Reading Increment: 1% LEL Alarm Set Points: A1: 10% LEL A2: 25% LEL A3: 50% LEL Accuracy: ±5% of reading or ±2% LEL |
| TE Sensor (thermal conductivity) | |
| Methane CH4 | Detection Range: 0 to 100 vol% Reading Increment: 1% vol% Alarm Set Points: N/A Accuracy: N/A |
| General Specifications | |
| Alarm Types | Gas alarm: Low and high adjustable Trouble: Low flow, Sensor connection, Low battery, Circuit error, Calibration failure Man Down Alarm Panic Alarm |
| Display | Digital LCD, autobacklight, peak bar display, auto display rotation, and customize order of gases |
| Communication | Bluetooth, IrDA |
| Audible Alarm | 95 dB at 1' (0.30 m) |
| Languages | English, Japanese, French, Spanish, Portuguese, Italian, German, Russian, Korean, Chinese (simplified), Chinese (traditional), Vietnamese, Slovak, Czech, Turkish, Polish |
| Continuous Operation | 28 hours on Lithium-ion battery pack. Complete recharge in 6 hours. 8 hours Alkaline battery pack (3 AA size in each pack) |
| Operating Temp. & Humidity | -4 to 122°F (-20 to 50°C), 0 to 95% RH non condensing |
| Case Material | Dust and water resistant with IP-67 approval (exclude sample hose and probe) |
| Warranty | Three years material (including R sensors) and workmanship 2 years for IR sensors and ESS (except Cl2) One year for TE, Cl2 and PID sensors (Two months for T1.7 eV lamp) |
| Dimensions | 2.6 x 7.9 x 2.2" (6.60 x 20.07 x 5.59 cm) |
| Weight | 17.6 oz (500 g) with lithium battery pack 16 oz (450 g) with alkaline batteries |