With a powerful fixed system controller for two points of gas detection, this two-channel wall mount controller is capable of connecting directly to sensors for LEL level combustibles, oxygen, hydrogen sulfide, or carbon monoxide.
With a powerful fixed system controller for two points of gas detection, this two-channel wall mount controller is capable of connecting directly to sensors for LEL level combustibles, oxygen, hydrogen sulfide, or carbon monoxide.
With a corrosion resistant build and weather-tight seal, this two channel wall mount controller has a compact wall mount design.
Features
Applications
| Temperature | Operating: -4 to 122°F (-20 to 50°C) Storage: -4 to 158°F (-20 to 70°C) |
| Enclosure Rating | NEMA 4X enclosure, waterproof, chemical, and weather resistant Suitable for indoor and outdoor installations |
| Conduit Connection | ¾" (1.9 cm) NPT conduit hubs 3 provided: 2 for sensor wiring and 1 for power & relay wiring |
| Wiring Termination | Screw type terminal block, 14 gauge maximum |
| Display | Alphanumeric display with backlighting. 20 characters per line (4 lines each) |
| Audio | Built-in audible alarm: 94 dB (mounted on enclosure) Coded output: pulsing = gas alarm, steady = fail |
| Visual | 4 LED’s on the front cover for alarm status indication, pilot, and malfunction |
| Power | 100 to 240 V AC or 24 V DC standard |
| Controls | 4 internal push buttons for setup, programming, and calibration 1 external push button for alarm reset |
| Sampling Methods | Accepts diffusion or sample draw heads |
| Approvals | CSA Certified to CSA C22.2 No. 1010 ANSI/ISA S82.01 |
| Dimensions | 10.5 x 8.5 x 6.3" (267 x 216 x 158 mm) |
| Temperature | Operating: -4 to 122°F (-20 to 50°C) Storage: -4 to 158°F (-20 to 70°C) |
| Enclosure Rating | NEMA 4X enclosure, waterproof, chemical, and weather resistant Suitable for indoor and outdoor installations |
| Conduit Connection | ¾" (1.9 cm) NPT conduit hubs 3 provided: 2 for sensor wiring and 1 for power & relay wiring |
| Wiring Termination | Screw type terminal block, 14 gauge maximum |
| Display | Alphanumeric display with backlighting. 20 characters per line (4 lines each) |
| Audio | Built-in audible alarm: 94 dB (mounted on enclosure) Coded output: pulsing = gas alarm, steady = fail |
| Visual | 4 LED’s on the front cover for alarm status indication, pilot, and malfunction |
| Power | 100 to 240 V AC or 24 V DC standard |
| Controls | 4 internal push buttons for setup, programming, and calibration 1 external push button for alarm reset |
| Sampling Methods | Accepts diffusion or sample draw heads |
| Approvals | CSA Certified to CSA C22.2 No. 1010 ANSI/ISA S82.01 |
| Dimensions | 10.5 x 8.5 x 6.3" (267 x 216 x 158 mm) |