Small and portable, this VLF/DC hipot tester features an integrated Tan Delta measurement system to perform an advanced diagnostic on cable insulation and shield conditions. Moreover, this tester includes a communication system via USB or Bluetooth for transferring results to the TD Control Center reporting software.
Our rentals come fully calibrated to traceable standards. Have your own instrument? We also offer calibration services for this model (CERTIVLF1).
Small and portable, this VLF/DC hipot tester features an integrated Tan Delta measurement system to perform an advanced diagnostic on cable insulation and shield conditions. Moreover, this tester includes a communication system via USB or Bluetooth for transferring results to the TD Control Center reporting software.
Our rentals come fully calibrated to traceable standards. Have your own instrument? We also offer calibration services for this model (CERTIVLF1).
This product exceeds standard shipping dimensions/weight, as such it does not qualify for free shipping. We will contact you with your shipping costs.
The provided technology is highly valuable for conducting in-depth diagnostics on cable systems, as it offers crucial insights into the state of the cable insulation and shield. Additionally, test results can conveniently be transferred to a USB memory stick or wirelessly transmitted via Bluetooth to a computer for future analysis and reporting. The package includes a top-notch reporting software called TD Control Center, along with a calibration certificate, corona protection shields, a Bluetooth dongle, and an accessories tote.
Features
Input Voltage | 100 to 240 V, 50/60 Hz (400 VA) |
Output Voltage | Sinusoidal: 0 to 30 kV peak/21 kV rms DC: ±0 to 28 kV Squarewave: 28 kV Accuracy: ±1% Resolution: 0.1 kV |
Output Current | 0 to 20 mA (Resolution 1 μA) accuracy: ±1% |
Resistance Range | 0.1 MW to 5GW |
VLF Output Frequency | 0.01 to 0.1Hz in steps of 0.01 Hz (default 0.1 Hz) -auto frequency selection |
Output Load | 0.5 μF @ 0.1 Hz @ 20kV rms 5 μF @ 0.01 @ 20kV rms 10.0 μF maximum capacitance* |
Output Models | AC (VLF) symmetrical and load independent across full range, DC (positive or negative polarity), burn-/fault condition or fault trip mode, jacket/sheath testing |
Sheath Test/Sheath Fault Location | KV: 0 to 10 kV Trip current: 0.1 to 5 mA Pulse/period: Variable |
Safety | 50/60 Hz - 12 kV feedback protection/dual discharge device (internal) |
Memory | 50 test records stored (internal) |
Metering | Voltage and current (true rms and/or peak), tan delta, capacitance, resistance, time, flashover voltage |
Tan Delta Measurement Resolution | ±1 x 10 |
Duty Cycle | Continuous |
HV Cable | 16.5' (5m) with alligator clamps |
Software | TD control center |
Computer Interfaces | Bluetooth: Standard USB: Standard |
Environmental Conditions | Storage: -25to 75°C/-13 to 167°F Operating: -5 to 45°C/23 to 113°F |
Dimensions | 16.9 x 9.4 x 13.4" (430 x 240 x 340 mm) |
Weight | 31 lbs (14 kg) |
Input Voltage | 100 to 240 V, 50/60 Hz (400 VA) |
Output Voltage | Sinusoidal: 0 to 30 kV peak/21 kV rms DC: ±0 to 28 kV Squarewave: 28 kV Accuracy: ±1% Resolution: 0.1 kV |
Output Current | 0 to 20 mA (Resolution 1 μA) accuracy: ±1% |
Resistance Range | 0.1 MW to 5GW |
VLF Output Frequency | 0.01 to 0.1Hz in steps of 0.01 Hz (default 0.1 Hz) -auto frequency selection |
Output Load | 0.5 μF @ 0.1 Hz @ 20kV rms 5 μF @ 0.01 @ 20kV rms 10.0 μF maximum capacitance* |
Output Models | AC (VLF) symmetrical and load independent across full range, DC (positive or negative polarity), burn-/fault condition or fault trip mode, jacket/sheath testing |
Sheath Test/Sheath Fault Location | KV: 0 to 10 kV Trip current: 0.1 to 5 mA Pulse/period: Variable |
Safety | 50/60 Hz - 12 kV feedback protection/dual discharge device (internal) |
Memory | 50 test records stored (internal) |
Metering | Voltage and current (true rms and/or peak), tan delta, capacitance, resistance, time, flashover voltage |
Tan Delta Measurement Resolution | ±1 x 10 |
Duty Cycle | Continuous |
HV Cable | 16.5' (5m) with alligator clamps |
Software | TD control center |
Computer Interfaces | Bluetooth: Standard USB: Standard |
Environmental Conditions | Storage: -25to 75°C/-13 to 167°F Operating: -5 to 45°C/23 to 113°F |
Dimensions | 16.9 x 9.4 x 13.4" (430 x 240 x 340 mm) |
Weight | 31 lbs (14 kg) |