Reliable for field testing, get accurate voltage and current measurements with this hipot AC tester designed to test insulating booms on work platforms and bucket trucks. Additionally, this tester features a high-voltage divider, a triple-range current meter, a guard circuit, and a fast-acting circuit breaker for safety.
Our rentals come fully calibrated to traceable standards. Have your own instrument? We also offer calibration services for this model (CERTIFL1).
Reliable for field testing, get accurate voltage and current measurements with this hipot AC tester designed to test insulating booms on work platforms and bucket trucks. Additionally, this tester features a high-voltage divider, a triple-range current meter, a guard circuit, and a fast-acting circuit breaker for safety.
Our rentals come fully calibrated to traceable standards. Have your own instrument? We also offer calibration services for this model (CERTIFL1).
This product exceeds standard shipping dimensions/weight, as such it does not qualify for free shipping. We will contact you with your shipping costs.
The HVT Series of AC Hipot Testers are an economical solution to field-testing of bucket trucks, aerial platforms, vacuum interrupters, breakers, switchgear, and other electrical apparatus. Each model includes a handcart for portability and is complete with an input line cord, interconnecting cable and ground leads.
This model is specifically designed for ANSI/SIA A92.2 specification procedures for testing insulating booms on work platforms and bucket trucks. The HVT series assures accurate voltage and current measurements using a high voltage divider and triple range current meter in the return leg of the high voltage transformer. A guard circuit prevents stray or surface leakage from being measured by the current meter. To ensure safe operation the unit is equipped with a fast acting circuit breaker, zero start interlock and provision for an external interlock.
Features
Applications
System Output (V) | 0 to 50 kV AC 0 to 100 kV AC |
System Output (A) | 50 mA (100 kV Tap) 100 mA (50 kV Tap) |
Meter | Voltage: 0 to 25/50/100 kV Current: 0 to 1/10/100 mA Accuracy: ±2% of full scale |
Voltage Divider Location | External |
Input Voltage and Frequency | In the model number, designate 'A' for 120 V/60 Hz input or 'B' for 230 V/50 Hz input |
Duty Cycle | 5 minutes ON/5 minutes OFF repeated maximum of 6 times, then OFF for 2 hrs |
Dimensions | 17.4 x 31.9 x 14.5" (44.2 x 36.8 x 81 cm) including handcart |
Weight | 240 lbs (109 kg) Shipping: 306 lbs (139 kg) |
System Output (V) | 0 to 50 kV AC 0 to 100 kV AC |
System Output (A) | 50 mA (100 kV Tap) 100 mA (50 kV Tap) |
Meter | Voltage: 0 to 25/50/100 kV Current: 0 to 1/10/100 mA Accuracy: ±2% of full scale |
Voltage Divider Location | External |
Input Voltage and Frequency | In the model number, designate 'A' for 120 V/60 Hz input or 'B' for 230 V/50 Hz input |
Duty Cycle | 5 minutes ON/5 minutes OFF repeated maximum of 6 times, then OFF for 2 hrs |
Dimensions | 17.4 x 31.9 x 14.5" (44.2 x 36.8 x 81 cm) including handcart |
Weight | 240 lbs (109 kg) Shipping: 306 lbs (139 kg) |