This compact autoranging True RMS clamp meter is capable of measuring AC/DC current and voltage, resistance, frequency, capacitance, duty cycle and temperature. Featuring a 50,000 count backlit LCD display, double molded plastic housing, the R5030 includes diode check and continuity functions and a non-contact voltage detector built into the clamp tip.
This product includes a Traceable Calibration Certificate with full Data and Uncertainties.
Features
| AC/DC Current | |
| Range | 50, 500A |
| Accuracy | AC: ±(2.8% rdg. +30 dgt.) DC: ±(2.5% rdg. +30 dgt.) |
| Resolution | 0.01, 0.1, 1A |
| AC/DC Voltage | |
| Range | AC: 500mV, 5, 50, 500, 750V DC: 500mV, 5, 50, 500, 1000V |
| Accuracy | AC: ±(1.0% rdg. +30 dgt.) DC: ±(0.1% rdg. +4 dgt.) |
| Resolution | AC/DC: 0.1mV, 0.001, 0.01, 0.1, 1V |
| Resistance | |
| Range | 500Ω, 5, 50, 500kΩ, 5, 50MΩ |
| Accuracy | ±(1.0% rdg. +4 dgt.) 0.1Ω, 0.001, 0.01, 0.1kΩ, 0.001, 0.01MΩ |
| Capacitance | |
| Range | 500, 5000nF, 50, 500µF, 5mF |
| Accuracy | ±(3.5% rdg. +10 dgt.) |
| Resolution | 0.01, 0.1nF, 0.01, 0.1μF, 0.1mF |
| Frequency | |
| Range | 10kHz |
| Accuracy | ±(0.5% rdg. +10 dgt.) |
| Resolution | 0.001Hz |
| Temperature | |
| Range | -148 to 1832°F (-100 to 1000°C) |
| Accuracy | ±(1.0% rdg. + 4.5°F) ±(1.0% rdg. + 2.5°C) |
| Resolution | 1°F, 1°C |
| General Specifications | |
| Range Selection | Autoranging / Manual |
| True RMS | Yes |
| Display | 50,000 count LCD display |
| Display Hold | Yes |
| Relative Mode | Yes |
| Diode Test | Yes |
| Backlit Display | Yes |
| Continuity Check | Audible signal if resistance <35Ω |
| Duty Cycle | Yes |
| Non-Contact Voltage Detector | Yes |
| Autoshut off | Yes (after 15 mins) |
| Power Supply | 2 x AAA |
| Low Battery Indicator | Yes |
| Jaw Opening | 1.2" (30mm), up to 350 MCM |
| Overvoltage Category | CAT. III 600V |
| Product Certifications | CE |
| Operating Temperature | 32 to 122°F (0 to 50°C) |
| Storage Temperature | -4 to 140°F (-20 to 60°C) |
| Dimensions | 7.9 x 2.6 x 1.5" (200 x 66 x 37 mm) |
| Weight | 8.1oz (230g) |
Industrial maintenance teams performing scheduled and preventative maintenance on electro-mechanical equipment and systems.
Facilities, building maintenance and electricians looking to troubleshoot electrical equipment installation problems.
Click on a category to view a selection of compatible accessories with the REED R5030 500A AC/DC Clamp Meter with Temperature and Non-Contact Voltage Detector, True RMS, .
| AC/DC Current | |
| Range | 50, 500A |
| Accuracy | AC: ±(2.8% rdg. +30 dgt.) DC: ±(2.5% rdg. +30 dgt.) |
| Resolution | 0.01, 0.1, 1A |
| AC/DC Voltage | |
| Range | AC: 500mV, 5, 50, 500, 750V DC: 500mV, 5, 50, 500, 1000V |
| Accuracy | AC: ±(1.0% rdg. +30 dgt.) DC: ±(0.1% rdg. +4 dgt.) |
| Resolution | AC/DC: 0.1mV, 0.001, 0.01, 0.1, 1V |
| Resistance | |
| Range | 500Ω, 5, 50, 500kΩ, 5, 50MΩ |
| Accuracy | ±(1.0% rdg. +4 dgt.) 0.1Ω, 0.001, 0.01, 0.1kΩ, 0.001, 0.01MΩ |
| Capacitance | |
| Range | 500, 5000nF, 50, 500µF, 5mF |
| Accuracy | ±(3.5% rdg. +10 dgt.) |
| Resolution | 0.01, 0.1nF, 0.01, 0.1μF, 0.1mF |
| Frequency | |
| Range | 10kHz |
| Accuracy | ±(0.5% rdg. +10 dgt.) |
| Resolution | 0.001Hz |
| Temperature | |
| Range | -148 to 1832°F (-100 to 1000°C) |
| Accuracy | ±(1.0% rdg. + 4.5°F) ±(1.0% rdg. + 2.5°C) |
| Resolution | 1°F, 1°C |
| General Specifications | |
| Range Selection | Autoranging / Manual |
| True RMS | Yes |
| Display | 50,000 count LCD display |
| Display Hold | Yes |
| Relative Mode | Yes |
| Diode Test | Yes |
| Backlit Display | Yes |
| Continuity Check | Audible signal if resistance <35Ω |
| Duty Cycle | Yes |
| Non-Contact Voltage Detector | Yes |
| Autoshut off | Yes (after 15 mins) |
| Power Supply | 2 x AAA |
| Low Battery Indicator | Yes |
| Jaw Opening | 1.2" (30mm), up to 350 MCM |
| Overvoltage Category | CAT. III 600V |
| Product Certifications | CE |
| Operating Temperature | 32 to 122°F (0 to 50°C) |
| Storage Temperature | -4 to 140°F (-20 to 60°C) |
| Dimensions | 7.9 x 2.6 x 1.5" (200 x 66 x 37 mm) |
| Weight | 8.1oz (230g) |
Industrial maintenance teams performing scheduled and preventative maintenance on electro-mechanical equipment and systems.
Facilities, building maintenance and electricians looking to troubleshoot electrical equipment installation problems.
Click on a category to view a selection of compatible accessories with the REED R5030 500A AC/DC Clamp Meter with Temperature and Non-Contact Voltage Detector, True RMS, .