Omega RSC-T-4-4-5 Retractable Thermocouple Sensor Cable, type T, SMP-M to SMP-F, 20'

Model: RSC-T-4-4-5

Omega RSC-T-4-4-5 Retractable Thermocouple Sensor Cable, type T, SMP-M to SMP-F, 20'-

Image is for reference only, refer to product info for complete details.

Omega RSC-T-4-4-5 Retractable Thermocouple Sensor Cable, type T, SMP-M to SMP-F, 20'

Model: RSC-T-4-4-5

Spring-coiled with a TPE jacket, this Type T retractable sensor cable extends up to 20' (6 m) and is rated for use over -22 to 220°F (-30 to 105°C). It has stranded 28 AWG conductors terminated SMP-M Connector to SMP-F Connector, color-coded to ANSI standard limits of error. Furthermore, it supports handheld and bench electronic indicators for portable temperature measurement.

Spring-coiled with a TPE jacket, this Type T retractable sensor cable extends up to 20' (6 m) and is rated for use over -22 to 220°F (-30 to 105°C). It has stranded 28 AWG conductors terminated SMP-M Connector to SMP-F Connector, color-coded to ANSI standard limits of error. Furthermore, it supports handheld and bench electronic indicators for portable temperature measurement.

Your Price $112.00 CAD
Availability 2 to 3 Weeks
Quantity

OMEGA RSC-T-4-4-5 Offers

OMEGA Retractable Sensor Cable is color coded and spring coiled, for use with thermocouples, RTDs and thermistors. To achieve a superior jacket construction, OMEGA has employed the latest in jacketing material: TPE (thermoplastic elastomer), a unique family of thermoplastics which exhibits characteristics previously found only in rubber compounds.

TPE is extremely tough and flexible, and has excellent abrasion resistance. Our special construction technique yields an expansion rate of up to 500%. OMEGA's retractable sensor cables are specifically recommended for use with electronic-type indicators, either panel, handheld or bench type models.

Features

  • Type T thermocouple calibration (J, K and E also available; 3-wire copper for RTDs and thermistors also available)
  • Expansion ratio up to 500% — 1' (30 cm) of cable stretches to 5' (150 cm)
  • TPE plastic jacket for indoor and outdoor use
  • Retracted coil length of 4' (120 cm) nominal with 6" (15 cm) straight ends (1', 2' and 3' also available)
  • Ideal for use with handheld and benchstand electronic indicators

Applications

  • Portable temperature measurement with handheld meters
  • Bench and panel electronic indicator connections
  • Connecting thermocouple and RTD probes to readouts without cable slack
  • Field and laboratory spot-check temperature measurement
  • Retractable sensor leads for test stations and carts

OMEGA RSC-T-4-4-5 Specifications

Series RSC (19 mm / 0.75" OD) / RSCM (16 mm / 0.63" OD)
Insulation TPE thermoplastic elastomer outer jacket
Inner conductors PFA
Calibrations ANSI Type J, K, T, E and 3-wire copper for RTDs and thermistors
Thermocouple wire conformity Standard limits of error, per ANSI MC 96.1 (1975)
Temperature rating -22 to 220°F (-30 to 105°C)
Construction 28 gauge stranded wire (7 strand x 36 gauge)
Expansion ratio Up to 500%
Length tolerance ±10%
Calibration Type T
Cable length 4' (122 cm) coiled, extends to 20' (6 m)
Termination SMP-M Connector to SMP-F Connector
Jacket color Blue
Positive wire color Blue
Negative wire color Red
Wire gauge 28 AWG
Dimensions Outside diameter: 0.75" (19 mm)

What's included with the OMEGA RSC-T-4-4-5

  • Omega RSC-T-4-4-5 Retractable Thermocouple Sensor Cable, type T, SMP-M to SMP-F, 20'

Click on a category to view a selection of compatible accessories with the Omega RSC-T-4-4-5 Retractable Thermocouple Sensor Cable, type T, SMP-M to SMP-F, 20'.

Omega SMP-T-M Miniature Thermocouple Connector, type T male, glass-filled nylon SMP-T-M
Rated for use over -20 to 356°F (-29 to 180°C), this Type T male miniature thermocouple connector has a glass-filled nylon body. It accepts stranded or solid thermocouple wire and uses ANSI/IEC color coding for fast, correct connections. Additionally, it is suited to connecting thermocouple wire and probes to extension wire and instruments.




Omega OST-T-M Standard Thermocouple Connector, type T male, glass-filled nylon OST-T-M
Built with a glass-filled nylon body, this Type T male standard thermocouple connector is rated for use over -20 to 356°F (-29 to 180°C). It accepts stranded or solid thermocouple wire and uses ANSI/IEC color coding for fast, correct connections. It is commonly used for connecting thermocouple wire and probes to extension wire and instruments.




Omega OST-T-F Standard Thermocouple Connector, type T female, glass-filled nylon OST-T-F
Made for field and panel wiring, this Type T female standard thermocouple connector has a glass-filled nylon body rated for use over -20 to 356°F (-29 to 180°C). It accepts stranded or solid thermocouple wire and uses ANSI/IEC color coding for fast, correct connections. Common uses include connecting thermocouple wire and probes to extension wire and instruments.




Omega SMP-T-F Miniature Thermocouple Connector, type T female, glass-filled nylon SMP-T-F
Made for field and panel wiring, this Type T female miniature thermocouple connector has a glass-filled nylon body rated for use over -20 to 356°F (-29 to 180°C). It accepts stranded or solid thermocouple wire and uses ANSI/IEC color coding for fast, correct connections. Common uses include connecting thermocouple wire and probes to extension wire and instruments.




Ask a question about Omega RSC-T-4-4-5 Retractable Thermocouple Sensor Cable, type T, SMP-M to SMP-F, 20'

Customer Reviews for the OMEGA RSC-T-4-4-5

OMEGA RSC-T-4-4-5 Offers

OMEGA Retractable Sensor Cable is color coded and spring coiled, for use with thermocouples, RTDs and thermistors. To achieve a superior jacket construction, OMEGA has employed the latest in jacketing material: TPE (thermoplastic elastomer), a unique family of thermoplastics which exhibits characteristics previously found only in rubber compounds.

TPE is extremely tough and flexible, and has excellent abrasion resistance. Our special construction technique yields an expansion rate of up to 500%. OMEGA's retractable sensor cables are specifically recommended for use with electronic-type indicators, either panel, handheld or bench type models.

Features

  • Type T thermocouple calibration (J, K and E also available; 3-wire copper for RTDs and thermistors also available)
  • Expansion ratio up to 500% — 1' (30 cm) of cable stretches to 5' (150 cm)
  • TPE plastic jacket for indoor and outdoor use
  • Retracted coil length of 4' (120 cm) nominal with 6" (15 cm) straight ends (1', 2' and 3' also available)
  • Ideal for use with handheld and benchstand electronic indicators

Applications

  • Portable temperature measurement with handheld meters
  • Bench and panel electronic indicator connections
  • Connecting thermocouple and RTD probes to readouts without cable slack
  • Field and laboratory spot-check temperature measurement
  • Retractable sensor leads for test stations and carts

OMEGA RSC-T-4-4-5 Specifications

Series RSC (19 mm / 0.75" OD) / RSCM (16 mm / 0.63" OD)
Insulation TPE thermoplastic elastomer outer jacket
Inner conductors PFA
Calibrations ANSI Type J, K, T, E and 3-wire copper for RTDs and thermistors
Thermocouple wire conformity Standard limits of error, per ANSI MC 96.1 (1975)
Temperature rating -22 to 220°F (-30 to 105°C)
Construction 28 gauge stranded wire (7 strand x 36 gauge)
Expansion ratio Up to 500%
Length tolerance ±10%
Calibration Type T
Cable length 4' (122 cm) coiled, extends to 20' (6 m)
Termination SMP-M Connector to SMP-F Connector
Jacket color Blue
Positive wire color Blue
Negative wire color Red
Wire gauge 28 AWG
Dimensions Outside diameter: 0.75" (19 mm)

What's included with the OMEGA RSC-T-4-4-5

  • Omega RSC-T-4-4-5 Retractable Thermocouple Sensor Cable, type T, SMP-M to SMP-F, 20'

Click on a category to view a selection of compatible accessories with the Omega RSC-T-4-4-5 Retractable Thermocouple Sensor Cable, type T, SMP-M to SMP-F, 20'.

Omega SMP-T-M Miniature Thermocouple Connector, type T male, glass-filled nylon SMP-T-M
Rated for use over -20 to 356°F (-29 to 180°C), this Type T male miniature thermocouple connector has a glass-filled nylon body. It accepts stranded or solid thermocouple wire and uses ANSI/IEC color coding for fast, correct connections. Additionally, it is suited to connecting thermocouple wire and probes to extension wire and instruments.




Omega OST-T-M Standard Thermocouple Connector, type T male, glass-filled nylon OST-T-M
Built with a glass-filled nylon body, this Type T male standard thermocouple connector is rated for use over -20 to 356°F (-29 to 180°C). It accepts stranded or solid thermocouple wire and uses ANSI/IEC color coding for fast, correct connections. It is commonly used for connecting thermocouple wire and probes to extension wire and instruments.




Omega OST-T-F Standard Thermocouple Connector, type T female, glass-filled nylon OST-T-F
Made for field and panel wiring, this Type T female standard thermocouple connector has a glass-filled nylon body rated for use over -20 to 356°F (-29 to 180°C). It accepts stranded or solid thermocouple wire and uses ANSI/IEC color coding for fast, correct connections. Common uses include connecting thermocouple wire and probes to extension wire and instruments.




Omega SMP-T-F Miniature Thermocouple Connector, type T female, glass-filled nylon SMP-T-F
Made for field and panel wiring, this Type T female miniature thermocouple connector has a glass-filled nylon body rated for use over -20 to 356°F (-29 to 180°C). It accepts stranded or solid thermocouple wire and uses ANSI/IEC color coding for fast, correct connections. Common uses include connecting thermocouple wire and probes to extension wire and instruments.




Ask a question about Omega RSC-T-4-4-5 Retractable Thermocouple Sensor Cable, type T, SMP-M to SMP-F, 20'

Customer Reviews for the OMEGA RSC-T-4-4-5

More OMEGA Products