Built for ambient temperature monitoring, this thermocouple data logger is supplied with NOMAD, 2 Measurements, TC. It has internal channel temperature range of -40 to 176°F (-40 to 80°C). It also suits industrial process temperature recording.

Built for ambient temperature monitoring, this thermocouple data logger is supplied with NOMAD, 2 Measurements, TC. It has internal channel temperature range of -40 to 176°F (-40 to 80°C). It also suits industrial process temperature recording.

Your Price $374.00 CAD
Availability 2 to 3 Weeks
Quantity

OMEGA OM-CP-TC101A Offers

The OM-CP-TC101A is a state-of-the-art low-cost battery powered thermocouple data logger. The OM-CP-TC101A offers a 10 year battery life, 1 second reading rate, a multiple start/stop function, ultra-high speed download capability, 1,000,000 reading storage capacity, optional memory wrap, battery life indicator, optional password protection, programmable high-low alarms and more.

Features

  • Dual channel/ambient and remote
  • 10 year battery life
  • 1 second reading rate
  • Multiple start/stop function
  • Accepts thermocouple types j, k, t, e, r, s, b, n
  • Ultra high speed download
  • Memory: 1,000,000 readings
  • Memory wrap around
  • Battery life indicator
  • Programmable high and low alarms

Applications

  • Ambient temperature monitoring
  • Remote thermocouple temperature monitoring
  • Industrial process temperature recording
  • Environmental monitoring
  • Laboratory data logging

OMEGA OM-CP-TC101A Specifications

Series OM-CP-TC101A
Type thermocouple data logger
Configuration NOMAD
Configuration 2 Measurements
Configuration TC
Configuration 1M Max Samples
Configuration Battery
Configuration USB
Configuration 1 s
Internal Channel Temperature Range -40 to 176°F (-40 to 80°C)
Internal Channel Temperature Resolution 0.018°F (0.1°C)
Internal Channel Calibrated Accuracy ±0.9°F (0.5°C)
Remote Channel Thermocouple Types J, K, T, E, R, S, B, N
Remote Channel Thermocouple Connection Female subminiature (SMP) connector
Remote Channel Cold Junction Compensation Automatic based on internal channel
Maximum Thermocouple Resistance 100 Ω
Reading Rate 1 reading every second to 1 every 24 hours
Memory 1,000,000 readings; software configurable memory wrap 500,000 readings in multiple start/stop mode or trigger settings mode
Memory Wrap Around Yes (software configurable)
Start Modes Immediate start; Delay start up to 18 months; Multiple pushbutton start/stop
Stop Modes Manual through software; Timed (specific date and time)
Battery Type 3.6 V lithium battery (included); user replaceable
Battery Life 10 years typical at a 15 minute reading rate
Data Format Date and time stamped °C, °F, K, °R, μV, mV, V
Time Accuracy ±1 minute/month at 68°F (20°C) stand alone data logging
Computer Interface USB (interface cable required); 115,200 baud
Software Windows® XP SP3/Vista/7 and 8 (32-bit and 64-bit)
Operating Environment -40 to 176°F (-40 to 80°C), 0 to 95% RH non-condensing
Materials Data Logger: ABS plastic
Alarm Programmable high and low limits; alarm is activated when temperature reaches or exceeds set limits
Alarm Delay A cumulative alarm delay may be set in which the device will activate that alarm (via LED) only when the device has recorded a user specified time duration of data
Trigger Settings High and low limits may be set for the thermocouple channel. Once data meets or exceeds sets limits, the device will record to memory. Bi-level start and stop triggers can also be programmed. Users can specify the number or readings to take after the device triggers.
LED Functionality Green LED Blinks: 10 second rate to indicate logging; 15 second rate to indicate delay start mode. Red LED Blinks: 10 second rate to indicate low battery and/or full memory; 1 second rate to indicate an alarm condition
Password Protection An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password
Waterbox Enclosure Material (optional OM-CP-WATERBOX101A) Black anodized aluminum
Remote Thermocouple Range/Resolution/Accuracy, Type J -346 to 1400°F (-210 to 760°C), 0.1°C, ±0.5°C
Remote Thermocouple Range/Resolution/Accuracy, Type K -454 to 2498°F (-270 to 1370°C), 0.1°C, ±0.5°C
Remote Thermocouple Range/Resolution/Accuracy, Type T -454 to 752°F (-270 to 400°C), 0.1°C, ±0.5°C
Remote Thermocouple Range/Resolution/Accuracy, Type E -454 to 1796°F (-270 to 980°C), 0.1°C, ±0.5°C
Remote Thermocouple Range/Resolution/Accuracy, Type R -58 to 3200°F (-50 to 1760°C), 0.5°C, ±2.0°C
Remote Thermocouple Range/Resolution/Accuracy, Type S -58 to 3200°F (-50 to 1760°C), 0.5°C, ±2.0°C
Remote Thermocouple Range/Resolution/Accuracy, Type B -58 to 3308°F (-50 to 1820°C), 0.5°C, ±2.0°C
Remote Thermocouple Range/Resolution/Accuracy, Type N -454 to 2372°F (-270 to 1300°C), 0.1°C, ±0.5°C
Dimensions Data Logger: 1.4 x 2.2 x 0.6" (36 x 56 x 16 mm)
Waterbox Enclosure Dimensions (optional OM-CP-WATERBOX101A) 74 H x 148 W x 1.54" (39 mm) D (2.9 x 5.8 x 1.5" (7.4 x 14.7 x 3.8 cm))
Weight 0.9 oz (24 g)

What's included with the OMEGA OM-CP-TC101A

  • Omega OM-CP-TC101A Thermocouple Data Logger, 2 measurements

Ask a question about Omega OM-CP-TC101A Thermocouple Data Logger, 2 measurements

Customer Reviews for the OMEGA OM-CP-TC101A

OMEGA OM-CP-TC101A Offers

The OM-CP-TC101A is a state-of-the-art low-cost battery powered thermocouple data logger. The OM-CP-TC101A offers a 10 year battery life, 1 second reading rate, a multiple start/stop function, ultra-high speed download capability, 1,000,000 reading storage capacity, optional memory wrap, battery life indicator, optional password protection, programmable high-low alarms and more.

Features

  • Dual channel/ambient and remote
  • 10 year battery life
  • 1 second reading rate
  • Multiple start/stop function
  • Accepts thermocouple types j, k, t, e, r, s, b, n
  • Ultra high speed download
  • Memory: 1,000,000 readings
  • Memory wrap around
  • Battery life indicator
  • Programmable high and low alarms

Applications

  • Ambient temperature monitoring
  • Remote thermocouple temperature monitoring
  • Industrial process temperature recording
  • Environmental monitoring
  • Laboratory data logging

OMEGA OM-CP-TC101A Specifications

Series OM-CP-TC101A
Type thermocouple data logger
Configuration NOMAD
Configuration 2 Measurements
Configuration TC
Configuration 1M Max Samples
Configuration Battery
Configuration USB
Configuration 1 s
Internal Channel Temperature Range -40 to 176°F (-40 to 80°C)
Internal Channel Temperature Resolution 0.018°F (0.1°C)
Internal Channel Calibrated Accuracy ±0.9°F (0.5°C)
Remote Channel Thermocouple Types J, K, T, E, R, S, B, N
Remote Channel Thermocouple Connection Female subminiature (SMP) connector
Remote Channel Cold Junction Compensation Automatic based on internal channel
Maximum Thermocouple Resistance 100 Ω
Reading Rate 1 reading every second to 1 every 24 hours
Memory 1,000,000 readings; software configurable memory wrap 500,000 readings in multiple start/stop mode or trigger settings mode
Memory Wrap Around Yes (software configurable)
Start Modes Immediate start; Delay start up to 18 months; Multiple pushbutton start/stop
Stop Modes Manual through software; Timed (specific date and time)
Battery Type 3.6 V lithium battery (included); user replaceable
Battery Life 10 years typical at a 15 minute reading rate
Data Format Date and time stamped °C, °F, K, °R, μV, mV, V
Time Accuracy ±1 minute/month at 68°F (20°C) stand alone data logging
Computer Interface USB (interface cable required); 115,200 baud
Software Windows® XP SP3/Vista/7 and 8 (32-bit and 64-bit)
Operating Environment -40 to 176°F (-40 to 80°C), 0 to 95% RH non-condensing
Materials Data Logger: ABS plastic
Alarm Programmable high and low limits; alarm is activated when temperature reaches or exceeds set limits
Alarm Delay A cumulative alarm delay may be set in which the device will activate that alarm (via LED) only when the device has recorded a user specified time duration of data
Trigger Settings High and low limits may be set for the thermocouple channel. Once data meets or exceeds sets limits, the device will record to memory. Bi-level start and stop triggers can also be programmed. Users can specify the number or readings to take after the device triggers.
LED Functionality Green LED Blinks: 10 second rate to indicate logging; 15 second rate to indicate delay start mode. Red LED Blinks: 10 second rate to indicate low battery and/or full memory; 1 second rate to indicate an alarm condition
Password Protection An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password
Waterbox Enclosure Material (optional OM-CP-WATERBOX101A) Black anodized aluminum
Remote Thermocouple Range/Resolution/Accuracy, Type J -346 to 1400°F (-210 to 760°C), 0.1°C, ±0.5°C
Remote Thermocouple Range/Resolution/Accuracy, Type K -454 to 2498°F (-270 to 1370°C), 0.1°C, ±0.5°C
Remote Thermocouple Range/Resolution/Accuracy, Type T -454 to 752°F (-270 to 400°C), 0.1°C, ±0.5°C
Remote Thermocouple Range/Resolution/Accuracy, Type E -454 to 1796°F (-270 to 980°C), 0.1°C, ±0.5°C
Remote Thermocouple Range/Resolution/Accuracy, Type R -58 to 3200°F (-50 to 1760°C), 0.5°C, ±2.0°C
Remote Thermocouple Range/Resolution/Accuracy, Type S -58 to 3200°F (-50 to 1760°C), 0.5°C, ±2.0°C
Remote Thermocouple Range/Resolution/Accuracy, Type B -58 to 3308°F (-50 to 1820°C), 0.5°C, ±2.0°C
Remote Thermocouple Range/Resolution/Accuracy, Type N -454 to 2372°F (-270 to 1300°C), 0.1°C, ±0.5°C
Dimensions Data Logger: 1.4 x 2.2 x 0.6" (36 x 56 x 16 mm)
Waterbox Enclosure Dimensions (optional OM-CP-WATERBOX101A) 74 H x 148 W x 1.54" (39 mm) D (2.9 x 5.8 x 1.5" (7.4 x 14.7 x 3.8 cm))
Weight 0.9 oz (24 g)

What's included with the OMEGA OM-CP-TC101A