Omega OM-CP-RTDTEMP101A RTD Temperature Data Logger, 1 measurement

Model: OM-CP-RTDTEMP101A

Omega OM-CP-RTDTEMP101A RTD Temperature Data Logger, 1 measurement

Model: OM-CP-RTDTEMP101A

With NOMAD, Precision, Temperature, this rtd temperature data logger is used for precision temperature monitoring and environmental monitoring. It has temperature measurement range of -328 to 1562°F (-200 to 850°C).

With NOMAD, Precision, Temperature, this rtd temperature data logger is used for precision temperature monitoring and environmental monitoring. It has temperature measurement range of -328 to 1562°F (-200 to 850°C).

Your Price $469.00 CAD
Availability 2 to 3 Weeks
Quantity

OMEGA OM-CP-RTDTEMP101A Offers

The OM-CP-RTDTEMP101A is part of a new series of low cost, state-of-the-art data logging devices. The OM-CP-RTDTEMP101A offers a 10 year battery life, a multiple start/stop function, ultra-high speed download capability, 1,340,000 reading storage capacity, optional memory wrap, precision RTD sensing element, battery life indicator, optional password protection, programmable high-low alarms and more.

Features

  • 100 Ω pt RTD input
  • 10 year battery life
  • ±0.05°C (±0.09°F) accuracy
  • Multiple start/stop function
  • Ultra high speed download
  • 1,340,000 reading storage capacity
  • Memory wrap
  • Precision RTD sensing element
  • Battery life indicator
  • Optional password protection
  • Programmable high and low alarms
  • Field upgradeable

Applications

  • Precision temperature monitoring
  • Laboratory data logging
  • Environmental monitoring
  • Cold chain and storage monitoring
  • Industrial process temperature recording

OMEGA OM-CP-RTDTEMP101A Specifications

Series OM-CP-RTDTEMP101A
Type rtd temperature data logger
Configuration NOMAD
Configuration Precision
Configuration Temperature
Configuration 1 Measurement
Input RTD
Configuration 670K Max Samples
Configuration Battery
Configuration USB
Configuration 1 s
Temperature Sensor External 100 Ω Pt RTD, a = 0.00385
Temperature Measurement Range -328 to 1562°F (-200 to 850°C)
Temperature Resolution 0.0018°F (0.001°C)
Nominal Range 18 to 400 Ω
Resolution 0.0001 Ω
Calibrated Accuracy ±0.05°C (±0.09°F); ±0.015 Ω (0 to 200 Ω); ±0.01% of readings (200 to 400 Ω)
Input Connection Removable screw terminal; 2-, 3- or 4-wire
Temperature Effect on Span < 2 ppm/°C
Temperature Effect on Offset <10 ppm cumulative over entire range
Reading Rate 1 reading every second to 1 every 24 hours
Memory 1,340,000 readings; software configurable memory wrap 666,000 readings in multiple start/stop mode
Memory Wrap Around Yes
Start Modes Immediate start; Delay start up to 18 months; Multiple pushbutton start/stop
Stop Modes Manual through software; Timed (specific date and time)
Battery Type 3.6 V lithium battery (included); user replaceable
Battery Life 10 years typical, at a 15 minute rate
Data Format Date and time stamped °C, °F, K, °R
Time Accuracy ±1 minute/month at 68°F (20°C), stand alone data logging
Computer Interface USB (interface cable required); 115,200 baud
Software XP SP3/Vista and Windows®/7 and 8 (32 and 64-bit)
Operating Environment -40 to 176°F (-40 to 80°C), 0 to 95% RH non-condensing
Materials Data Logger: ABS Plastic
Alarm Programmable high and low limits; alarm is activated when temperature reaches or exceeds set limits
LED Functionality Green LED Blinks: 10 second rate to indicate logging; 15 second rate to indicate delay start mode. Red LED Blinks: 10 second rate to indicate low battery and/or full memory; 1 second rate to indicate an alarm condition
Password Protection An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password
Calibration Digital calibration through software
Calibration Date Automatically recorded within device
Waterbox Enclosure Material (optional OM-CP-WATERBOX101A) Black anodized aluminum
Dimensions Data Logger: 1.4 x 2.2 x 0.6" (36 x 56 x 16 mm)
Waterbox Enclosure Dimensions (optional OM-CP-WATERBOX101A) 74 H x 148 W x 1.54" (39 mm) D (2.9 x 5.8 x 1.5" (7.4 x 14.7 x 3.8 cm))
Weight 0.9 oz (24 g)

What's included with the OMEGA OM-CP-RTDTEMP101A

  • Omega OM-CP-RTDTEMP101A RTD Temperature Data Logger, 1 measurement

Ask a question about Omega OM-CP-RTDTEMP101A RTD Temperature Data Logger, 1 measurement

Customer Reviews for the OMEGA OM-CP-RTDTEMP101A

OMEGA OM-CP-RTDTEMP101A Offers

The OM-CP-RTDTEMP101A is part of a new series of low cost, state-of-the-art data logging devices. The OM-CP-RTDTEMP101A offers a 10 year battery life, a multiple start/stop function, ultra-high speed download capability, 1,340,000 reading storage capacity, optional memory wrap, precision RTD sensing element, battery life indicator, optional password protection, programmable high-low alarms and more.

Features

  • 100 Ω pt RTD input
  • 10 year battery life
  • ±0.05°C (±0.09°F) accuracy
  • Multiple start/stop function
  • Ultra high speed download
  • 1,340,000 reading storage capacity
  • Memory wrap
  • Precision RTD sensing element
  • Battery life indicator
  • Optional password protection
  • Programmable high and low alarms
  • Field upgradeable

Applications

  • Precision temperature monitoring
  • Laboratory data logging
  • Environmental monitoring
  • Cold chain and storage monitoring
  • Industrial process temperature recording

OMEGA OM-CP-RTDTEMP101A Specifications

Series OM-CP-RTDTEMP101A
Type rtd temperature data logger
Configuration NOMAD
Configuration Precision
Configuration Temperature
Configuration 1 Measurement
Input RTD
Configuration 670K Max Samples
Configuration Battery
Configuration USB
Configuration 1 s
Temperature Sensor External 100 Ω Pt RTD, a = 0.00385
Temperature Measurement Range -328 to 1562°F (-200 to 850°C)
Temperature Resolution 0.0018°F (0.001°C)
Nominal Range 18 to 400 Ω
Resolution 0.0001 Ω
Calibrated Accuracy ±0.05°C (±0.09°F); ±0.015 Ω (0 to 200 Ω); ±0.01% of readings (200 to 400 Ω)
Input Connection Removable screw terminal; 2-, 3- or 4-wire
Temperature Effect on Span < 2 ppm/°C
Temperature Effect on Offset <10 ppm cumulative over entire range
Reading Rate 1 reading every second to 1 every 24 hours
Memory 1,340,000 readings; software configurable memory wrap 666,000 readings in multiple start/stop mode
Memory Wrap Around Yes
Start Modes Immediate start; Delay start up to 18 months; Multiple pushbutton start/stop
Stop Modes Manual through software; Timed (specific date and time)
Battery Type 3.6 V lithium battery (included); user replaceable
Battery Life 10 years typical, at a 15 minute rate
Data Format Date and time stamped °C, °F, K, °R
Time Accuracy ±1 minute/month at 68°F (20°C), stand alone data logging
Computer Interface USB (interface cable required); 115,200 baud
Software XP SP3/Vista and Windows®/7 and 8 (32 and 64-bit)
Operating Environment -40 to 176°F (-40 to 80°C), 0 to 95% RH non-condensing
Materials Data Logger: ABS Plastic
Alarm Programmable high and low limits; alarm is activated when temperature reaches or exceeds set limits
LED Functionality Green LED Blinks: 10 second rate to indicate logging; 15 second rate to indicate delay start mode. Red LED Blinks: 10 second rate to indicate low battery and/or full memory; 1 second rate to indicate an alarm condition
Password Protection An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password
Calibration Digital calibration through software
Calibration Date Automatically recorded within device
Waterbox Enclosure Material (optional OM-CP-WATERBOX101A) Black anodized aluminum
Dimensions Data Logger: 1.4 x 2.2 x 0.6" (36 x 56 x 16 mm)
Waterbox Enclosure Dimensions (optional OM-CP-WATERBOX101A) 74 H x 148 W x 1.54" (39 mm) D (2.9 x 5.8 x 1.5" (7.4 x 14.7 x 3.8 cm))
Weight 0.9 oz (24 g)

What's included with the OMEGA OM-CP-RTDTEMP101A

  • Omega OM-CP-RTDTEMP101A RTD Temperature Data Logger, 1 measurement

Ask a question about Omega OM-CP-RTDTEMP101A RTD Temperature Data Logger, 1 measurement

Customer Reviews for the OMEGA OM-CP-RTDTEMP101A