Omega OM-CP-RFTCTEMP2000A Wireless Thermocouple Temperature Data Logger with LCD, 1 measurement

Model: OM-CP-RFTCTEMP2000A

Omega OM-CP-RFTCTEMP2000A Wireless Thermocouple Temperature Data Logger with LCD, 1 measurement

Model: OM-CP-RFTCTEMP2000A

Configured for temperature, 1 measurement, thermocouple, this wireless thermocouple temperature data logger suits monitoring perishable goods and chemicals monitoring. It has internal channel temperature range of -4 to 140°F (-20 to 60°C).

Configured for temperature, 1 measurement, thermocouple, this wireless thermocouple temperature data logger suits monitoring perishable goods and chemicals monitoring. It has internal channel temperature range of -4 to 140°F (-20 to 60°C).

Your Price $814.00 CAD
Availability 2 to 3 Weeks
Quantity

OMEGA OM-CP-RFTCTEMP2000A Offers

The OM-CP-RFTCTEMP2000A is a wireless thermocouple based data logger with digital display. The device measures ambient temperatures, as well as remote temperature via a thermocouple (sold separately), making it ideal for monitoring perishable goods, vaccine storage, chemicals and more.

Features

  • Wireless 2-way communication
  • Ambient and thermocouple temperature monitoring
  • View data in real-time
  • 3 year battery life
  • Battery life indicator
  • Field upgradeable
  • Audible and led alarm indicators
  • Trigger settings
  • Cumulative alarm delay

Applications

  • Monitoring perishable goods
  • Vaccine storage
  • Chemicals monitoring
  • Ambient temperature monitoring
  • Remote thermocouple temperature monitoring

OMEGA OM-CP-RFTCTEMP2000A Specifications

Series OM-CP-RFTCTEMP2000A
Type wireless thermocouple temperature data logger
Configuration Temperature
Configuration 1 Measurement
Input Thermocouple
Configuration 16128 Max Samples
Configuration LCD Display
Configuration Battery
Configuration Wireless 2.4GHz IEEE802.15.4
Configuration 1 s
Internal Channel Temperature Range -4 to 140°F (-20 to 60°C)
Internal Channel Temperature Resolution 0.18°F (0.1°C)
Internal Channel Calibrated Accuracy ±0.10°C (±0.18°F) 32 to 131°F (0 to 55°C)
Internal Channel Response Time 10 minutes free air
Remote Channel Thermocouple Connection Female subminiature (SMP) connector
Remote Channel Cold Junction Compensation Automatic based on internal channel
Maximum Thermocouple Resistance 100 Ω
Remote Channel Response Time 2 minutes to 63% of change
RF Frequency 2.45 GHz IEEE 802.15.4 ultra-low power wireless transceiver with fully bi-directional communication
Band ISM band 2.405-2.48 GHz
Output Power +0 dBm typical
Receiver Sensitivity (OM-CP-RFC1000-EXT) -95 dBm typical
Range 2000' (610 m) maximum outdoors (line of sight unobstructed); 500' (152 m) maximum indoors (typical urban)
Reading Rate One reading every second up to one every 24 hours
Memory 16,128 per channel
Memory Wrap Around Yes
Start Modes Immediate start
Battery Type 9 V lithium battery (included); user replaceable
Battery Life 3 years typical at 1 minute reading rate
Data Format For Display: °C or °F; For Software: Date and time stamped °C, K, °F, or °R
Time Accuracy ±1 minute/month maximum
Computer Interface USB to mini USB, 250,000 baud for standalone operation or OM-CP-RFC1000-EXT required for wireless operation
Software XP SP3/Vista/7/8 (32 and 64-bit)
Operating Environment -4 to 140°F (-20 to 60°C), 0 to 95% RH non-condensing
Enclosure Material ABS plastic
Alarm Programmable high and low limits for temperature and humidity. Alarm is activated when temperature or humidity reaches or exceeds set limits.
Alarm Delay A cumulative alarm delay may be set in which the device will activate the alarm (via LED) only when the device has recorded a user specified time duration of data.
Audible Alarm Functionality 1 beep per second for reading above/below threshold
LED Functionality Green LED blinks every 5 seconds to indicate unit is logging; Blue LED blinks every 15 seconds to indicate unit is in wireless mode; Red LED blinks every 1 second to indicate alarm condition
Calibration Digital calibration through software
Calibration Date Automatically recorded within device
Remote Thermocouple Range/Resolution/Accuracy, Type J -346 to 1400°F (-210 to 760°C), 0.1°C, ±0.5°C
Remote Thermocouple Range/Resolution/Accuracy, Type K -454 to 2498°F (-270 to 1370°C), 0.1°C, ±0.5°C
Remote Thermocouple Range/Resolution/Accuracy, Type T -454 to 752°F (-270 to 400°C), 0.1°C, ±0.5°C
Remote Thermocouple Range/Resolution/Accuracy, Type E -454 to 1796°F (-270 to 980°C), 0.1°C, ±0.5°C
Remote Thermocouple Range/Resolution/Accuracy, Type R -58 to 3200°F (-50 to 1760°C), 0.5°C, ±2.0°C
Remote Thermocouple Range/Resolution/Accuracy, Type S -58 to 3200°F (-50 to 1760°C), 0.5°C, ±2.0°C
Remote Thermocouple Range/Resolution/Accuracy, Type B 122 to 3308°F (50 to 1820°C), 0.5°C, ±2.0°C
Remote Thermocouple Range/Resolution/Accuracy, Type N -454 to 2372°F (-270 to 1300°C), 0.1°C, ±0.5°C
Dimensions 3.0 x 3.5 x 0.95" (76.2 x 88.9 x 24.1 mm)
Weight 4.1 oz (116 g)

What's included with the OMEGA OM-CP-RFTCTEMP2000A

  • Omega OM-CP-RFTCTEMP2000A Wireless Thermocouple Temperature Data Logger with LCD, 1 measurement

Ask a question about Omega OM-CP-RFTCTEMP2000A Wireless Thermocouple Temperature Data Logger with LCD, 1 measurement

Customer Reviews for the OMEGA OM-CP-RFTCTEMP2000A

OMEGA OM-CP-RFTCTEMP2000A Offers

The OM-CP-RFTCTEMP2000A is a wireless thermocouple based data logger with digital display. The device measures ambient temperatures, as well as remote temperature via a thermocouple (sold separately), making it ideal for monitoring perishable goods, vaccine storage, chemicals and more.

Features

  • Wireless 2-way communication
  • Ambient and thermocouple temperature monitoring
  • View data in real-time
  • 3 year battery life
  • Battery life indicator
  • Field upgradeable
  • Audible and led alarm indicators
  • Trigger settings
  • Cumulative alarm delay

Applications

  • Monitoring perishable goods
  • Vaccine storage
  • Chemicals monitoring
  • Ambient temperature monitoring
  • Remote thermocouple temperature monitoring

OMEGA OM-CP-RFTCTEMP2000A Specifications

Series OM-CP-RFTCTEMP2000A
Type wireless thermocouple temperature data logger
Configuration Temperature
Configuration 1 Measurement
Input Thermocouple
Configuration 16128 Max Samples
Configuration LCD Display
Configuration Battery
Configuration Wireless 2.4GHz IEEE802.15.4
Configuration 1 s
Internal Channel Temperature Range -4 to 140°F (-20 to 60°C)
Internal Channel Temperature Resolution 0.18°F (0.1°C)
Internal Channel Calibrated Accuracy ±0.10°C (±0.18°F) 32 to 131°F (0 to 55°C)
Internal Channel Response Time 10 minutes free air
Remote Channel Thermocouple Connection Female subminiature (SMP) connector
Remote Channel Cold Junction Compensation Automatic based on internal channel
Maximum Thermocouple Resistance 100 Ω
Remote Channel Response Time 2 minutes to 63% of change
RF Frequency 2.45 GHz IEEE 802.15.4 ultra-low power wireless transceiver with fully bi-directional communication
Band ISM band 2.405-2.48 GHz
Output Power +0 dBm typical
Receiver Sensitivity (OM-CP-RFC1000-EXT) -95 dBm typical
Range 2000' (610 m) maximum outdoors (line of sight unobstructed); 500' (152 m) maximum indoors (typical urban)
Reading Rate One reading every second up to one every 24 hours
Memory 16,128 per channel
Memory Wrap Around Yes
Start Modes Immediate start
Battery Type 9 V lithium battery (included); user replaceable
Battery Life 3 years typical at 1 minute reading rate
Data Format For Display: °C or °F; For Software: Date and time stamped °C, K, °F, or °R
Time Accuracy ±1 minute/month maximum
Computer Interface USB to mini USB, 250,000 baud for standalone operation or OM-CP-RFC1000-EXT required for wireless operation
Software XP SP3/Vista/7/8 (32 and 64-bit)
Operating Environment -4 to 140°F (-20 to 60°C), 0 to 95% RH non-condensing
Enclosure Material ABS plastic
Alarm Programmable high and low limits for temperature and humidity. Alarm is activated when temperature or humidity reaches or exceeds set limits.
Alarm Delay A cumulative alarm delay may be set in which the device will activate the alarm (via LED) only when the device has recorded a user specified time duration of data.
Audible Alarm Functionality 1 beep per second for reading above/below threshold
LED Functionality Green LED blinks every 5 seconds to indicate unit is logging; Blue LED blinks every 15 seconds to indicate unit is in wireless mode; Red LED blinks every 1 second to indicate alarm condition
Calibration Digital calibration through software
Calibration Date Automatically recorded within device
Remote Thermocouple Range/Resolution/Accuracy, Type J -346 to 1400°F (-210 to 760°C), 0.1°C, ±0.5°C
Remote Thermocouple Range/Resolution/Accuracy, Type K -454 to 2498°F (-270 to 1370°C), 0.1°C, ±0.5°C
Remote Thermocouple Range/Resolution/Accuracy, Type T -454 to 752°F (-270 to 400°C), 0.1°C, ±0.5°C
Remote Thermocouple Range/Resolution/Accuracy, Type E -454 to 1796°F (-270 to 980°C), 0.1°C, ±0.5°C
Remote Thermocouple Range/Resolution/Accuracy, Type R -58 to 3200°F (-50 to 1760°C), 0.5°C, ±2.0°C
Remote Thermocouple Range/Resolution/Accuracy, Type S -58 to 3200°F (-50 to 1760°C), 0.5°C, ±2.0°C
Remote Thermocouple Range/Resolution/Accuracy, Type B 122 to 3308°F (50 to 1820°C), 0.5°C, ±2.0°C
Remote Thermocouple Range/Resolution/Accuracy, Type N -454 to 2372°F (-270 to 1300°C), 0.1°C, ±0.5°C
Dimensions 3.0 x 3.5 x 0.95" (76.2 x 88.9 x 24.1 mm)
Weight 4.1 oz (116 g)

What's included with the OMEGA OM-CP-RFTCTEMP2000A

  • Omega OM-CP-RFTCTEMP2000A Wireless Thermocouple Temperature Data Logger with LCD, 1 measurement

Ask a question about Omega OM-CP-RFTCTEMP2000A Wireless Thermocouple Temperature Data Logger with LCD, 1 measurement

Customer Reviews for the OMEGA OM-CP-RFTCTEMP2000A

More OMEGA Products