Built for remote temperature monitoring, this RTD temperature transmitter pairs a Pt100 element at Class A tolerance with a measuring range of -58 to 932°F (-50 to 500°C) in a 0.25 x 6" probe with M12 connector.
Built for remote temperature monitoring, this RTD temperature transmitter pairs a Pt100 element at Class A tolerance with a measuring range of -58 to 932°F (-50 to 500°C) in a 0.25 x 6" probe with M12 connector.
The M12TX 100 Ω RTD sensor with built-in transmitter is programmable by a computer. This unique probe is ideal for areas with space limitations where traditional head connections are too large to fit.
The M12 thread design offers a secure industrial connection. The temperature transmitter is designed with mineral insulated cable probe (MgO) which allows the probe to have a minimum bend radius of three times the diameter.
Features
Applications
| Series | M12TX Series |
| Type | RTD Temperature Transmitter |
| Sensing element | Pt100 platinum RTD |
| Nominal resistance | 100 Ω at 0°C |
| Accuracy | Class A per IEC 60751 |
| Temperature range | -58 to 932°F (-50 to 500°C) |
| Sheath material | 316 SS |
| Connection | M12 Connector |
| Output | 4 to 20 mA (2-wire transmitter) |
| Body | Thermoplastic material |
| Probe Type | Compact mineral insulated cable AISI 316L SS |
| Probe Minimum Bending Radius | Three-times the outer diameter [except the sensing tip which length is 1.2" (30 mm)] |
| Range | -58 to 932°F (-50 to 500°C) |
| Tmax. Electronic | 176°F (80°C) |
| Transmitter Accuracy | Maximum of ±0.2°C or ±0.2% of span |
| Temperature Influence [Deviation from 20°C (68°F)] | Maximum of ±0.3°C/77°F (25°C) or ±0.3% of span/77°F (25°C) |
| Supply Voltage Influence | Negligible |
| Isolation In-Out | Non-isolated |
| Power Supply | 8.5 to 32 V DC (polarity protected) |
| Permissible Load | 700 @ 24 V DC [RLo= (Vsupply-8.5)/0.020] |
| Environment Conditions Temperature | -40 to 176°F (-40 to 80°C) for plastic body |
| Relative Humidity | 0 to 100% |
| EMC | In accordance to EN 61326 |
| Degree of Protection | IP65 and IP67 in accordance to IEC60529 |
| Zero Adjustments | Any value between -58 to 122°F (-50 to 50°C) |
| Minimum Span | 122°F (50°C) [if the zero value is set between one of these values: -40°F (-40°C), -4°F (-20°C), 32°F (0°C), 68°F (20°C), 104°F (40°C), the minimum span is 68°F (20°C) rather than 122°F (50°C)] |
| Sensor Break Monitoring | Selectable: Upscale (>21.0 mA) or downscale (<3.6 mA) action |
| Sensor Short-Circuit | Fixed to downscale (<3.6 mA) action |
| Sensor Error Compensation | Over 2 points (maximum 1% of span) |
| Factory Setting | 32 to 302°F (0 to 150°C)/sensor break >21 mA (upscale) |
| Signal | 4 to 20 mA |
| Factory Default | 4 to 20 mA = 32 to 302°F (0 to 150°C) |
| Range Configurations | Possible to set the input temperature range (span) by the M12TX-CONFIG-SET configuration kit (PC with OS Windows required) |
| Response Time (90%) | <50 ms |
| Response Time (in water to IEC751) | Diameter 0.12" (3 mm) <3.5 second, diameter 0.24" (6 mm) <13 second (time for reaching 63.2% of instantaneous temperature change) |
| Configurable Parameters | Temperature range (-58 to 1472°F (-50 to 800°C)), measure unit (+°C/°F/°K), sensor break monitoring (up scale/down scale), identifying name of the transmitter (16 alphanumeric characters), input sensor error compensation over one or two points |
| Probe dimensions | 0.25 x 6" (6.3 mm x 15.2 cm) |
| Dimensions | M12x1; Ø0.59" (15 mm); Ø0.23" (6 mm) diameter; 2.36" (60 mm) |
Click on a category to view a selection of compatible accessories with the Omega M12TX Series RTD Temperature Transmitter, Pt100, class A, 0.25 x 6" probe, M12 connector.
| Series | M12TX Series |
| Type | RTD Temperature Transmitter |
| Sensing element | Pt100 platinum RTD |
| Nominal resistance | 100 Ω at 0°C |
| Accuracy | Class A per IEC 60751 |
| Temperature range | -58 to 932°F (-50 to 500°C) |
| Sheath material | 316 SS |
| Connection | M12 Connector |
| Output | 4 to 20 mA (2-wire transmitter) |
| Body | Thermoplastic material |
| Probe Type | Compact mineral insulated cable AISI 316L SS |
| Probe Minimum Bending Radius | Three-times the outer diameter [except the sensing tip which length is 1.2" (30 mm)] |
| Range | -58 to 932°F (-50 to 500°C) |
| Tmax. Electronic | 176°F (80°C) |
| Transmitter Accuracy | Maximum of ±0.2°C or ±0.2% of span |
| Temperature Influence [Deviation from 20°C (68°F)] | Maximum of ±0.3°C/77°F (25°C) or ±0.3% of span/77°F (25°C) |
| Supply Voltage Influence | Negligible |
| Isolation In-Out | Non-isolated |
| Power Supply | 8.5 to 32 V DC (polarity protected) |
| Permissible Load | 700 @ 24 V DC [RLo= (Vsupply-8.5)/0.020] |
| Environment Conditions Temperature | -40 to 176°F (-40 to 80°C) for plastic body |
| Relative Humidity | 0 to 100% |
| EMC | In accordance to EN 61326 |
| Degree of Protection | IP65 and IP67 in accordance to IEC60529 |
| Zero Adjustments | Any value between -58 to 122°F (-50 to 50°C) |
| Minimum Span | 122°F (50°C) [if the zero value is set between one of these values: -40°F (-40°C), -4°F (-20°C), 32°F (0°C), 68°F (20°C), 104°F (40°C), the minimum span is 68°F (20°C) rather than 122°F (50°C)] |
| Sensor Break Monitoring | Selectable: Upscale (>21.0 mA) or downscale (<3.6 mA) action |
| Sensor Short-Circuit | Fixed to downscale (<3.6 mA) action |
| Sensor Error Compensation | Over 2 points (maximum 1% of span) |
| Factory Setting | 32 to 302°F (0 to 150°C)/sensor break >21 mA (upscale) |
| Signal | 4 to 20 mA |
| Factory Default | 4 to 20 mA = 32 to 302°F (0 to 150°C) |
| Range Configurations | Possible to set the input temperature range (span) by the M12TX-CONFIG-SET configuration kit (PC with OS Windows required) |
| Response Time (90%) | <50 ms |
| Response Time (in water to IEC751) | Diameter 0.12" (3 mm) <3.5 second, diameter 0.24" (6 mm) <13 second (time for reaching 63.2% of instantaneous temperature change) |
| Configurable Parameters | Temperature range (-58 to 1472°F (-50 to 800°C)), measure unit (+°C/°F/°K), sensor break monitoring (up scale/down scale), identifying name of the transmitter (16 alphanumeric characters), input sensor error compensation over one or two points |
| Probe dimensions | 0.25 x 6" (6.3 mm x 15.2 cm) |
| Dimensions | M12x1; Ø0.59" (15 mm); Ø0.23" (6 mm) diameter; 2.36" (60 mm) |