Configured for Tension/Compression, ± 0.03 %, 50 lbf (222.41 N), this load cell suits low-range tension and compression testing and industrial weighing. It has output of 3 mV/V ± 0.25% full scale.
Configured for Tension/Compression, ± 0.03 %, 50 lbf (222.41 N), this load cell suits low-range tension and compression testing and industrial weighing. It has output of 3 mV/V ± 0.25% full scale.
The LCCE S-Beam load cells are designed with mechanical overload protection to 500% of FS in both tension and compression. This unique design gives you an extra level of protection and functionality that is typically an extra cost option on most load cells. When overloaded, the load cell is protected by a unique locking design; when the overload is removed, the load cell unlocks and returns to normal function.
Features
Applications
| Series | LCCE Series |
| Type | load cell |
| Configuration | Tension/Compression |
| Accuracy | ± 0.03 % |
| Configuration | 50 lbf (222.41 N) |
| Configuration | 3 mV/V |
| Cable | 20' (6.1 m) Cable |
| Configuration | 1.9" (4.8 cm) (L) |
| Configuration | 0.65" (16.5 mm) (W) |
| Configuration | 2.5" (6.3 cm) (H) |
| Configuration | Low Range |
| Excitation | 10 V DC, 15 V maximum |
| Output | 3 mV/V ± 0.25% full scale |
| Standard Calibration | 5 point NIST traceable in tension 0%, 50%, 100%, 50%, 0% |
| Linearity | ± 0.03% full scale |
| Hysteresis | ± 0.05% full scale |
| Repeatability | ± 0.01% full scale |
| Zero Balance | ± 1% full scale |
| Creep in 20 minutes | ± 0.03% full scale |
| Operating Temperature | 0 to 150°F (-18 to 65°C) |
| Compensated Temperature | 0 to 150°F (-18 to 65°C) |
| Thermal Effects Zero | ± 0.0027% FS/°C |
| Thermal Effects Span | ± 0.0014% rdg/°C |
| Safe Overload | 500% capacity |
| Ultimate Overload | 500% capacity |
| Bridge Resistance | 350 Ω nominal |
| Protection Level | IP67 |
| Material | 17-4 PH SS element, aluminum side cover |
| Electrical Connection | 20' (6 m) 4-conductor 24 AWG jacketed cable |
| Capacity | 25 to 750 lb (11 to 340 kg) |
| Series | LCCE Series |
| Type | load cell |
| Configuration | Tension/Compression |
| Accuracy | ± 0.03 % |
| Configuration | 50 lbf (222.41 N) |
| Configuration | 3 mV/V |
| Cable | 20' (6.1 m) Cable |
| Configuration | 1.9" (4.8 cm) (L) |
| Configuration | 0.65" (16.5 mm) (W) |
| Configuration | 2.5" (6.3 cm) (H) |
| Configuration | Low Range |
| Excitation | 10 V DC, 15 V maximum |
| Output | 3 mV/V ± 0.25% full scale |
| Standard Calibration | 5 point NIST traceable in tension 0%, 50%, 100%, 50%, 0% |
| Linearity | ± 0.03% full scale |
| Hysteresis | ± 0.05% full scale |
| Repeatability | ± 0.01% full scale |
| Zero Balance | ± 1% full scale |
| Creep in 20 minutes | ± 0.03% full scale |
| Operating Temperature | 0 to 150°F (-18 to 65°C) |
| Compensated Temperature | 0 to 150°F (-18 to 65°C) |
| Thermal Effects Zero | ± 0.0027% FS/°C |
| Thermal Effects Span | ± 0.0014% rdg/°C |
| Safe Overload | 500% capacity |
| Ultimate Overload | 500% capacity |
| Bridge Resistance | 350 Ω nominal |
| Protection Level | IP67 |
| Material | 17-4 PH SS element, aluminum side cover |
| Electrical Connection | 20' (6 m) 4-conductor 24 AWG jacketed cable |
| Capacity | 25 to 750 lb (11 to 340 kg) |