Omega HH520 Thermometer, TC input, 4-channel

Model: HH520

Omega HH520 Thermometer, TC input, 4-channel

Model: HH520

This thermometer is configured for TC-Type, Battery, 4-CH. It has measurement range (type j) of -328 to 1832°F (-200 to 1000°C). It suits multi-channel temperature monitoring and hvac and refrigeration testing.

This thermometer is configured for TC-Type, Battery, 4-CH. It has measurement range (type j) of -328 to 1832°F (-200 to 1000°C). It suits multi-channel temperature monitoring and hvac and refrigeration testing.

Your Price $863.00 CAD
Availability 2 to 3 Weeks
Quantity

OMEGA HH520 Offers

The HH520 is a 4 channel handheld data logger/thermometer that accepts Types J, K, T and E thermocouples. Measurement settings and results are shown on the backlit LCD display. Data can be stored in the data logger and then downloaded to the computer or directly saved on the computer through the USB interface in real time.

Features

  • Measures types j, k, t, e thermocouples
  • Large backlit display shows all channels
  • USB interface -- pc software included
  • High accuracy, fast response
  • T1-t2 function
  • Temperature alarm function
  • Data hold function
  • Adjustable auto power off timer
  • Min/max/avg recording of all channels
  • Data logging up to 16,000 points for each channel
  • Recall function to instantly read-out up to 100 sets of manually saved data

Applications

  • Multi-channel temperature monitoring
  • Differential temperature measurement
  • HVAC and refrigeration testing
  • Laboratory and process temperature logging
  • Field engineering temperature measurement

OMEGA HH520 Specifications

Series HH520
Type thermometer
Configuration TC-Type
Configuration Battery
Channels 4-CH
Measurement Range (Type J) -328 to 1832°F (-200 to 1000°C)
Measurement Range (Type K) -328 to 2501°F (-200 to 1372°C)
Measurement Range (Type T) -328 to 752°F (-200 to 400°C)
Measurement Range (Type E) -328 to 1382°F (-200 to 750°C)
Accuracy ±(0.1% rdg + 0.7°C)/±(0.1% rdg + 1.4°F) between 64 to 82°F (18 to 28°C); ±(0.4% rdg + 0.7°C)/±(0.4% rdg + 1.4°F) below -148°F (-100°C) (Does Not Include Thermocouple Sensor Error)
Resolution 0.1°C <600°C (0.1°F <1000°F); 1.0°C ≥ 600°C (1.0°F ≥ 1000°F)
Temperature Coefficient 0.01% of reading + 0.05°C per °C (<18 or >28°C)
Input Protection 30 Vrms maximum
Sample Rate 2 samples/sec
Power Four 1.5 V "AAA" batteries (included); external power through USB interface
Battery Life 100 hrs approx (alkaline batteries)
Operating Environment 32 to 122°F (0 to 50°C); 10 to 90% RH non-condensing
Storage Environment -4 to 140°F (-20 to 60°C); 10 to 75% RH
Software Windows XP/Vista/7/8/10
Inputs Types J, K, T, E Thermocouples
Data Logging Up to 16,000 points for each channel; USB interface, PC software included
Dimensions 7.36 x 2.95 x 1.14" (187 H x 75 W x 1.14" (29 mm) D)
Weight 10.2 oz (290 g)

What's included with the OMEGA HH520

  • Omega HH520 Thermometer, TC input, 4-channel

Ask a question about Omega HH520 Thermometer, TC input, 4-channel

Customer Reviews for the OMEGA HH520

OMEGA HH520 Offers

The HH520 is a 4 channel handheld data logger/thermometer that accepts Types J, K, T and E thermocouples. Measurement settings and results are shown on the backlit LCD display. Data can be stored in the data logger and then downloaded to the computer or directly saved on the computer through the USB interface in real time.

Features

  • Measures types j, k, t, e thermocouples
  • Large backlit display shows all channels
  • USB interface -- pc software included
  • High accuracy, fast response
  • T1-t2 function
  • Temperature alarm function
  • Data hold function
  • Adjustable auto power off timer
  • Min/max/avg recording of all channels
  • Data logging up to 16,000 points for each channel
  • Recall function to instantly read-out up to 100 sets of manually saved data

Applications

  • Multi-channel temperature monitoring
  • Differential temperature measurement
  • HVAC and refrigeration testing
  • Laboratory and process temperature logging
  • Field engineering temperature measurement

OMEGA HH520 Specifications

Series HH520
Type thermometer
Configuration TC-Type
Configuration Battery
Channels 4-CH
Measurement Range (Type J) -328 to 1832°F (-200 to 1000°C)
Measurement Range (Type K) -328 to 2501°F (-200 to 1372°C)
Measurement Range (Type T) -328 to 752°F (-200 to 400°C)
Measurement Range (Type E) -328 to 1382°F (-200 to 750°C)
Accuracy ±(0.1% rdg + 0.7°C)/±(0.1% rdg + 1.4°F) between 64 to 82°F (18 to 28°C); ±(0.4% rdg + 0.7°C)/±(0.4% rdg + 1.4°F) below -148°F (-100°C) (Does Not Include Thermocouple Sensor Error)
Resolution 0.1°C <600°C (0.1°F <1000°F); 1.0°C ≥ 600°C (1.0°F ≥ 1000°F)
Temperature Coefficient 0.01% of reading + 0.05°C per °C (<18 or >28°C)
Input Protection 30 Vrms maximum
Sample Rate 2 samples/sec
Power Four 1.5 V "AAA" batteries (included); external power through USB interface
Battery Life 100 hrs approx (alkaline batteries)
Operating Environment 32 to 122°F (0 to 50°C); 10 to 90% RH non-condensing
Storage Environment -4 to 140°F (-20 to 60°C); 10 to 75% RH
Software Windows XP/Vista/7/8/10
Inputs Types J, K, T, E Thermocouples
Data Logging Up to 16,000 points for each channel; USB interface, PC software included
Dimensions 7.36 x 2.95 x 1.14" (187 H x 75 W x 1.14" (29 mm) D)
Weight 10.2 oz (290 g)

What's included with the OMEGA HH520

  • Omega HH520 Thermometer, TC input, 4-channel

Ask a question about Omega HH520 Thermometer, TC input, 4-channel