Made for inline water flow measurement, this indicating flow meter reads 1 to 15 GPM (3.8 to 56.8 LPM) and provides an analog output for remote monitoring. It is rated to 3500 psi (241 bar) at up to 240°F (116°C) and measures to ±2% through a 1/2" NPT connection. Works great for machine-tool and circulation flow monitoring.
Made for inline water flow measurement, this indicating flow meter reads 1 to 15 GPM (3.8 to 56.8 LPM) and provides an analog output for remote monitoring. It is rated to 3500 psi (241 bar) at up to 240°F (116°C) and measures to ±2% through a 1/2" NPT connection. Works great for machine-tool and circulation flow monitoring.
Available in 1/2" (13 mm), 3/4" (19 mm), and 11/4" (32 mm) sizes with anodized aluminum or brass. Comes with 15' (4.5 m) of stripped end integral cable. In the field, integral cable can be extended up to 1000' (300 m) with shielded copper cable.
Units are securely protected in a sturdy cast aluminum enclosure, and are easy to install and mount in any position, vertical or horizontal. Capable of monitoring fluids to 150 GPM or pneumatic lines to 1000 SCFM.
Features
Applications
| Temperature range | -20°F to 240°F (-29°C to 116°C) |
| Maximum pressure | 3500 psig (liquids); 1000 psig (gases) |
| Power requirement, 0 to 5 Vdc output | 10 to 30 Vdc @ 0.75 W maximum |
| Power requirement, 0 to 10 Vdc output | 12 to 30 Vdc @ 0.75 W maximum |
| Power requirement, 4 to 20 mA output | Loop-powered, 30 Vdc maximum |
| Power consumption | 25 mA maximum |
| Circuit protection | Reverse polarity and current limit |
| Repeatability | ±0.5% |
| Non-linearity | ±0.05% |
| Isolation | Inherently isolated from the piping system |
| Display | Fixed or toggle modes of operation for rate and totalizer display. 8-digit, 0.70" high numeric display for rate and total 8-digit 0.35" high alphanumeric display for units and setup |
| Response time | 1.0 sec |
| Temperature drift | 0.05% of span per °C maximum |
| Analog outputs | 4 to 20 mA into 1KΩ maximum; 0 to 5 Vdc into 10KΩ minimum; 0 to 10 Vdc into 10KΩ minimum |
| User connections | 15' pig-tail (standard) |
| Transmission distance, 4 to 20 mA | Limited by cable resistance |
| Transmission distance, 0 to 5 Vdc | 300 m (1000') maximum |
| Transmission distance, 0 to 10 Vdc | 300 m (1000') maximum |
| Enclosure material | Anodized and epoxy powder-coated aluminum with polycarbonate lens |
| Enclosure seals | Silicone gasket between enclosure and lens/cover FKM O-rings between enclosure and flow meter body |
| Enclosure connection | 4-pin connection (standard) |
| Enclosure fasteners | T303 SS |
| Enclosure rating | NEMA 12 and 13 (IP52/54) |
| Spider plate | T316 SS |
| Spring | T302 SS |
| Fasteners | T303 SS |
| Pressure seals | FKM |
| Lens | Polycarbonate |
| Internal magnet | PPS/ceramic |
| Enclosure seal | Silicone gasket |
| Flow range | 1 to 15 GPM |
| Medium | Water |
| NPT port size | 1/2 |
| Body | Brass |
| Retaining ring | T316 SS |
| Retaining spring | ST316 SS |
| Dimensions | 6.60" (168 mm) C Length: 5.27" (134 mm) D Length: 6.41" (163 mm) E Width: 6.00" (152 mm) F Width: 3.23" (82 mm) G Width: 3.00" (76 mm) H Width: 4.20" (107 mm) I Depth: 2.94" (75 mm) J Offset: 1.51" (38 mm) K Hole Dia.: 0.31" (8 mm) |
| Temperature range | -20°F to 240°F (-29°C to 116°C) |
| Maximum pressure | 3500 psig (liquids); 1000 psig (gases) |
| Power requirement, 0 to 5 Vdc output | 10 to 30 Vdc @ 0.75 W maximum |
| Power requirement, 0 to 10 Vdc output | 12 to 30 Vdc @ 0.75 W maximum |
| Power requirement, 4 to 20 mA output | Loop-powered, 30 Vdc maximum |
| Power consumption | 25 mA maximum |
| Circuit protection | Reverse polarity and current limit |
| Repeatability | ±0.5% |
| Non-linearity | ±0.05% |
| Isolation | Inherently isolated from the piping system |
| Display | Fixed or toggle modes of operation for rate and totalizer display. 8-digit, 0.70" high numeric display for rate and total 8-digit 0.35" high alphanumeric display for units and setup |
| Response time | 1.0 sec |
| Temperature drift | 0.05% of span per °C maximum |
| Analog outputs | 4 to 20 mA into 1KΩ maximum; 0 to 5 Vdc into 10KΩ minimum; 0 to 10 Vdc into 10KΩ minimum |
| User connections | 15' pig-tail (standard) |
| Transmission distance, 4 to 20 mA | Limited by cable resistance |
| Transmission distance, 0 to 5 Vdc | 300 m (1000') maximum |
| Transmission distance, 0 to 10 Vdc | 300 m (1000') maximum |
| Enclosure material | Anodized and epoxy powder-coated aluminum with polycarbonate lens |
| Enclosure seals | Silicone gasket between enclosure and lens/cover FKM O-rings between enclosure and flow meter body |
| Enclosure connection | 4-pin connection (standard) |
| Enclosure fasteners | T303 SS |
| Enclosure rating | NEMA 12 and 13 (IP52/54) |
| Spider plate | T316 SS |
| Spring | T302 SS |
| Fasteners | T303 SS |
| Pressure seals | FKM |
| Lens | Polycarbonate |
| Internal magnet | PPS/ceramic |
| Enclosure seal | Silicone gasket |
| Flow range | 1 to 15 GPM |
| Medium | Water |
| NPT port size | 1/2 |
| Body | Brass |
| Retaining ring | T316 SS |
| Retaining spring | ST316 SS |
| Dimensions | 6.60" (168 mm) C Length: 5.27" (134 mm) D Length: 6.41" (163 mm) E Width: 6.00" (152 mm) F Width: 3.23" (82 mm) G Width: 3.00" (76 mm) H Width: 4.20" (107 mm) I Depth: 2.94" (75 mm) J Offset: 1.51" (38 mm) K Hole Dia.: 0.31" (8 mm) |