Omega FL7000 Series Variable Area Flow Meter, air, 3 to 30 SCFH, 1/4" NPT female

Model: FL7215

Omega FL7000 Series Variable Area Flow Meter, air, 3 to 30 SCFH, 1/4" NPT female

Model: FL7215

This variable area flow meter measures air flow from 3 to 30 SCFH at ±6% accuracy. It has a 1/4" (6.3 mm) NPT Female connection rated to 100 psi (6.89 bar) and 100°F (38°C). It suits water flow measurement and oem equipment integration.

This variable area flow meter measures air flow from 3 to 30 SCFH at ±6% accuracy. It has a 1/4" (6.3 mm) NPT Female connection rated to 100 psi (6.89 bar) and 100°F (38°C). It suits water flow measurement and oem equipment integration.

Your Price $173.00 CAD
Availability 2 to 3 Weeks
Quantity

OMEGA FL7215 Offers

FL7000 OEM-style variable area flow meter are precisely machined from solid acrylic blocks. They are available in 50, 75, 100, 127, and 250 mm scale lengths (1.97, 2.96, 3.94, 5, and 9.85") and have accuracies between 2 and 6%.

Features

  • 50, 75, 100, 127, and 250 mm (1.97, 2.96, 3.94, 5, and 9.85") scale lengths
  • Floats are rod-guided in most models
  • Direct-reading scales

Applications

  • Water flow measurement
  • Air flow measurement
  • OEM equipment integration
  • Process flow indication
  • Laboratory flow monitoring

OMEGA FL7215 Specifications

Series FL7000 Series
Type variable area flow meter
Media Air
Flow range 3 to 30 SCFH
Accuracy ±6% full scale
Maximum pressure 100 psi (6.89 bar)
Process connection 1/4" (6.3 mm) NPT Female
Maximum temperature 100°F (38°C)
Construction Acrylic tube, 316 SS float and guide rod (no guide rod for FL7211 through FL7215 air meters), PVC end fittings (brass on FL7200 series), EPR O-rings
Maximum Pressure/Temperature (Water Ranges) 125 psig (8.6 bar) at 70°F (21°C); 130°F (54°C) at 0 psig
Maximum Pressure/Temperature (Air Ranges) 100 psig (6.9 bar) at 70°F (21°C); 100°F (38°C) at 0 psig
Capacities Water: 6.5 GPH to 20 GPM; Air: 2 SCFH to 62 SCFM
Scale Lengths 50, 75, 100, 127, and 250 mm (1.97, 2.96, 3.94, 5, and 9.85" (5, 7.5, 10, 12.7, and 25 cm))
Shipping Weights FL7200, 7300, 7500: 1 lb (0.45 kg); FL7400: 1.75 lb (0.79 kg); FL7600: 2.75 lb (1.25 kg)
Max Pressure/Temperature (Water Ranges) 125 psig (8.62 bar) at 70°F (21°C); 130°F (54°C) at 0 psig (0 bar)
Max Pressure/Temperature (Air Ranges) 100 psig (6.89 bar) at 70°F (21°C); 100°F (38°C) @ 0 psig (0 bar)
Full Scale Accuracy/Repeatability FL7200: 6/2%; FL7300: 6/1%; FL7400: 4/1%; FL7500: 3/1/2%; FL7600: 2/1/2%
Connection Size FL7200: 1/4 FNPT; FL7300: 1/2 FNPT; FL7400: 1 FNPT; FL7500: 1/2 FNPT; FL7600: 3/4 FNPT

What's included with the OMEGA FL7215

  • Omega FL7000 Series Variable Area Flow Meter, air, 3 to 30 SCFH, 1/4" NPT female

Ask a question about Omega FL7000 Series Variable Area Flow Meter, air, 3 to 30 SCFH, 1/4" NPT female

Customer Reviews for the OMEGA FL7215

OMEGA FL7215 Offers

FL7000 OEM-style variable area flow meter are precisely machined from solid acrylic blocks. They are available in 50, 75, 100, 127, and 250 mm scale lengths (1.97, 2.96, 3.94, 5, and 9.85") and have accuracies between 2 and 6%.

Features

  • 50, 75, 100, 127, and 250 mm (1.97, 2.96, 3.94, 5, and 9.85") scale lengths
  • Floats are rod-guided in most models
  • Direct-reading scales

Applications

  • Water flow measurement
  • Air flow measurement
  • OEM equipment integration
  • Process flow indication
  • Laboratory flow monitoring

OMEGA FL7215 Specifications

Series FL7000 Series
Type variable area flow meter
Media Air
Flow range 3 to 30 SCFH
Accuracy ±6% full scale
Maximum pressure 100 psi (6.89 bar)
Process connection 1/4" (6.3 mm) NPT Female
Maximum temperature 100°F (38°C)
Construction Acrylic tube, 316 SS float and guide rod (no guide rod for FL7211 through FL7215 air meters), PVC end fittings (brass on FL7200 series), EPR O-rings
Maximum Pressure/Temperature (Water Ranges) 125 psig (8.6 bar) at 70°F (21°C); 130°F (54°C) at 0 psig
Maximum Pressure/Temperature (Air Ranges) 100 psig (6.9 bar) at 70°F (21°C); 100°F (38°C) at 0 psig
Capacities Water: 6.5 GPH to 20 GPM; Air: 2 SCFH to 62 SCFM
Scale Lengths 50, 75, 100, 127, and 250 mm (1.97, 2.96, 3.94, 5, and 9.85" (5, 7.5, 10, 12.7, and 25 cm))
Shipping Weights FL7200, 7300, 7500: 1 lb (0.45 kg); FL7400: 1.75 lb (0.79 kg); FL7600: 2.75 lb (1.25 kg)
Max Pressure/Temperature (Water Ranges) 125 psig (8.62 bar) at 70°F (21°C); 130°F (54°C) at 0 psig (0 bar)
Max Pressure/Temperature (Air Ranges) 100 psig (6.89 bar) at 70°F (21°C); 100°F (38°C) @ 0 psig (0 bar)
Full Scale Accuracy/Repeatability FL7200: 6/2%; FL7300: 6/1%; FL7400: 4/1%; FL7500: 3/1/2%; FL7600: 2/1/2%
Connection Size FL7200: 1/4 FNPT; FL7300: 1/2 FNPT; FL7400: 1 FNPT; FL7500: 1/2 FNPT; FL7600: 3/4 FNPT

What's included with the OMEGA FL7215

  • Omega FL7000 Series Variable Area Flow Meter, air, 3 to 30 SCFH, 1/4" NPT female

Ask a question about Omega FL7000 Series Variable Area Flow Meter, air, 3 to 30 SCFH, 1/4" NPT female

Customer Reviews for the OMEGA FL7215

More OMEGA Products